Nutone 8664RP - Manual
Nutone 8664RP – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 2 – MOUNTING THE HOUSING; Mounting Using Mounting Tabs; INSTALLING DUCTWORK; FIGURE 3; FIGURE 4B
- Page 3 – FIGURE 5; CLEANING AND RELAMPING; Cleat
- Page 4 – FIGURE 1; INSTRUCTIONS D'INSTALLATION; IMPORTANTES DIRECTIVES DE SÉCURITÉ; INSTRUCTIONS D’INSTALLATION
- Page 6 – INSTALLATION DU BLOC-MOTEUR; NETTOYAGE ET REMPLACEMENT DE LA LAMPE
- Page 7 – Combinación de; INSTRUCCIONES IMPORTANTES DE SEGURIDAD; FIGURA 1
- Page 8 – CABLEADO; FIGURA 4A; FIGURA 3; FIGURA 4B
- Page 9 – FIGURA 5; LIMPIEZA Y CAMBIO DE BOMBILLAS
- Page 11 – PARTS LIST
READ & SAVE THESE INSTRUCTIONS!
INSTALLATION INSTRUCTIONS
Bathroom Exhaust
Fan/Light Combination
Suitable for use in insulated ceilings.
WARNING: To reduce the risk of fire or electrical shock, do not use this
fan with any solid-state speed control device. Do not install in a ceiling
insulated to a value greater than R-40.
IMPORTANT SAFETY INSTRUCTIONS
WARNING – TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR
INJURY TO PERSONS, OBSERVE THE FOLLOWING:
A. Use this unit only in the manner intended by the manufacturer.
If you have questions, contact the manufacturer.
B. Before servicing or cleaning unit, switch power off at Service Panel and
lock Service Panel to prevent power from being switched on accidentally.
When the service disconnecting means cannot be locked, securely fasten
a prominent warning device, such as a tag, to the service panel.
CAUTION:
For general ventilating use only. Do not use to exhaust hazardous or
explosive materials and vapors.
INSTALLATION INSTRUCTIONS
WARNING – TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR
INJURY TO PERSONS, OBSERVE THE FOLLOWING:
A. Installation work and electrical wiring must be done by qualified person(s)
in accordance with all applicable codes and standards, including fire-rated
construction.
B. Sufficient air is needed for proper combustion and exhausting of gases
through the flue (chimney) of fuel burning equipment to prevent back
drafting. Follow the heating equipment manufacturer's guideline and safety
standards such as those published by the National Fire Protection
Association (NFPA),
and the American Society for Heating, Refrigeration and Air Conditioning
Engineers (ASHRAE), and the local code authorities.
C. When cutting or drilling into wall or ceiling, do not damage electrical wiring
and other hidden utilities.
D. Ducted fans must always be vented to the outdoors.
E. If this unit is to be installed over a tub or shower, it must be marked as
appropriate for the application.
F. NEVER place a switch where it can be reached from a tub or shower.
G. For installation in sloped ceilings up to 12/12 pitch.
H. Ductwork must point up.
FOR BEST RESULTS
When installing the Exhaust Fan/Light in a new construction site, install
housing during the rough-in construction of the building. The blower unit,
reflector and grille should be installed after the finished ceiling is in place.
Refer to instructions on page 3
to install the Exhaust Fan/Light in an
existing finished building.
PLANNING DUCTWORK AND WIRING
1. Use 4" round duct.
2. Plan duct run from discharge opening of fan to the outside. For best fan
performance, make duct run as short as possible and use minimum
number of elbows.
3. Use optional NuTone ducting accessories as needed.
Wiring
Knockouts
FIGURE 1
MODEL: 8663RP, 8673RP, 8664RP
Suitable for use in shower or tub enclosure when used
with GFI protected branch circuit.
IMPORTANT:
Use wire suitable for 90°C.
Plan to run 120vAC house wiring (with ground) from power source, through
wall switches, to junction box in fan. For separate control of fan, light, and
night light three wall switches are required. See NuTone Catalog for accessory
switches. For separate control of fan, light, and night light, five conductors are
needed between the wall switch box and the fan's junction box. (Night light
not provided on 8664RP).
INSTALLATION IN A NEW
CONSTRUCTION SITE
PREPARATION
1.
Refer to Figure 1.
Remove power unit/blower assembly from housing.
A. Unplug power unit.
B. Remove screw (located next to plug-in receptacle) which holds
power/blower unit mounting plate in place. Save screw.
C. Lift mounting plate at end near the plug-in receptacle until blower
wheel clears the scroll.
D. Remove plate by pulling its tabs out of slots in housing. Set
power/blower unit aside until needed.
2. Remove one of the wiring knockouts from housing.
Housing
Scroll
Slots
Power/Blower
Unit
Reflector
Assembly
Night Light
Socket
(not provided
on 8664RP)
Wing Nut
Grille/Lens
Assembly
Mounting
Springs (2)
Duct
Collar
Tabs
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
MOUNTING THE HOUSING Note: When installing in existing construction, refer to page 3 Mounting Using Mounting Tabs Refer to Figure 2. 1. Locate fan housing next to ceiling joist.2. Use wood screws (not provided) to loosely attach housing to ceiling joist through keyhole slots in mounting tabs. 3. Adj...
POWER/BLOWER UNIT INSTALLATION 1. Refer to Figure 1. Place power/blower unit into housing so that mounting plate's tabs insert into slots in housing. 2. Press other end of mounting plate down until it is firmly seated over scroll and plug-in receptacles. 3. Secure mounting plate to housing with prov...
PREDECOUPEDE CABLAGE FIGURE 1 BOITIER REBORD FENTES BLOC-MOTEUR REFLECTEUR DOUILLE DEVEILLEUSE( n’accompagne pas le modèle8664RP ) VIS À PAPILLON ENSEMBLEGRILLE/COUVERCLE DE LAMPE RESSORTSDE MONTAGE INSTRUCTIONS D'INSTALLATION LIRE ET CONSERVER CES INSTRUCTIONS Ventilateur de salle debains avec écla...