Table of Contents:

  • Page 2 – MAKING CONNECTIONS; IMPORTANT: Prior to making wiring connections,; main source through wall switch to the fan location.; Refer to Figure 4. For vertical discharge installations, use; elbow and 3; FIGURE 1
  • Page 3 – FINAL ASSEMBLY INSTRUCTIONS; Check louvers in fan housing and outside wall cap to see; Refer to Figure 5. Install motor and blade assembly into; MAINTENANCE AND CLEANING; FILTER; Rinse thoroughly and allow to dry.; GRILLE; Use only a mild soap and water solution to clean the grille.; FIGURE 5
  • Page 4 – One Year Limited Warranty
Loading the manual

INSTALLATION INSTRUCTIONS

READ & SAVE THESE INSTRUCTIONS!

IMPORTANT SAFETY INSTRUCTIONS

WARNING: TO REDUCE THE RISK OF FIRE.

ELECTRIC SHOCK, OR INJURY TO PERSONS,
OBSERVE THE FOLLOWING:
A. Use this unit only in the manner intended by the

manufacturer. If you have questions, contact the
manufacturer.

B. Before servicing or cleaning unit, switch power off at

service panel and lock service panel to prevent power from
being switched on accidentally.
When the service disconnecting means cannot be locked,
securely fasten a prominent warning device, such as a tag,
to the service panel.

CAUTION:

For general ventilating use only. Do not use to exhaust

hazardous or explosive materials and vapors.

INSTALLATION INSTRUCTIONS

WARNING: TO REDUCE THE RISK OF FIRE,

ELECTRIC SHOCK, OR INJURY TO PERSONS,
OBSERVE THE FOLLOWING:
A. Installation work and electrical wiring must be done by

qualified person(s) in accordance with all applicable codes
and standards, including fire-rated construction.

B. Sufficient air is needed for proper combusition and

exhausting of gases through the flue (chimney) of fuel
burning equipment to prevent back drafting. Follow the
heating equipment manufacturer's guideline and safety
standards such as those published by the National Fire
Protection Association (NFPA), and the American Society
for Heating, Refrigeration and Air Conditioning Engineers
(ASHRAE), and the local code authorities.

C. When cutting or drilling into wall or ceiling, do not damage

electrical wiring and other hidden utilities.

D. Ducted fans must always be vented to the outdoors.
E. If this unit is to be installed over a tub or shower, it must be

marked as appropriate for the application.

F. NEVER place a switch where it can be reached from a tub

or shower.

• Do not mount over tub or in shower enclosure.
• Suitable for use with solid-state speed controls.

If the installation presents a problem that is not explained

here or if any parts of these instructions are not clear, consult
a professional installer. If you are not familiar with methods of
installing electrical wiring, or if you are not certain as to the
correctness of any step or procedure described, secure the
services of a qualified electrician.

INSTALLING THE HOUSING

• Cutout dimension: 9" diameter
• Blade Size: 8"
• Grille Diameter: 10

1

2

"

MPORTANT: Remove shipping tape that secures louver.

1. Slide hanger bars (adjustable for 24" O.C. joists) through

tabs in housing. Nail one hanger bar to joist and slide
ventilator to desired position. Nail second hanger bar to
joist: cocking it slightly to clamp fan into place.

8˝ Round Fan

MODEL: 8310

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - MAKING CONNECTIONS; IMPORTANT: Prior to making wiring connections,; main source through wall switch to the fan location.; Refer to Figure 4. For vertical discharge installations, use; elbow and 3; FIGURE 1

MAKING CONNECTIONS IMPORTANT: Prior to making wiring connections, disconnect electrical power at the main source and leave it offuntil the installation is complete. All wiring must comply withelectrical codes.1. Refer to Figure 1. Place wiring into the outlet box. Secure the connections with approve...

Page 3 - FINAL ASSEMBLY INSTRUCTIONS; Check louvers in fan housing and outside wall cap to see; Refer to Figure 5. Install motor and blade assembly into; MAINTENANCE AND CLEANING; FILTER; Rinse thoroughly and allow to dry.; GRILLE; Use only a mild soap and water solution to clean the grille.; FIGURE 5

FINAL ASSEMBLY INSTRUCTIONS 1. Check louvers in fan housing and outside wall cap to see that they are not damaged or binding. Louvre can bereadily removed by depressing spring bearings on end ofhinge pins. Refer to Figure 5. Install motor and blade assembly into housing. Be sure motor leads are towa...

Page 4 - One Year Limited Warranty

Product specifications subject to change without notice. 4820 Red Bank Road, Cincinnati, Ohio 45227 Printed in U.S.A., Rev. 4/01, Part No. 15851 One Year Limited Warranty WARRANTY OWNER: NuTone warrants to the original consumer purchaser of its products that such products will be free from defects i...

Other Nutone Models