Nutone AVD50N - Manual

Nutone AVD50N

Nutone AVD50N – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
Page: / 8

Table of Contents:

  • Page 2 – Page; OPERATING INSTRUCTION; MOUNTING THE CABINET DOOR; IRONING BOARD HEIGHT ADJUSTMENT; DO NOT WASH THE COVER
  • Page 3 – UNITÉ DE REPASSAGE INTEGRÉ; INSTALLATION; DETERMINEZ LA HAUTEUR AU DESSUS DU SOL.; ATTENTION; Uniquement pour le série AVD45 et AVD50); MODÈLES
  • Page 4 – INSTRUCTIONS D’UTILISATION; Panneau de Contrôle (Série AVD45 et AVD50); PORTE DE MEUBLE; MONTAGE DE LA PORTE DU MEUBLE; RÉGLAGE DE LA HAUTEUR DE LA
  • Page 5 – CENTRO DE PLANCHADO INTEGRAL; INSTALACIÓN; DETERMINE EL TAMAÑO DE LA CAVIDAD; INSTALE EL GABINETE DEL CENTRO DE; ADVERTENCIA; MODELOS
  • Page 6 – INSTRUCCIONES DE USO; Consola de control (Series AVD45 y AVD50); PUERTA DE GABINETE; MONTAJE DE LA PUERTA; AJUSTE DE LA ALTURA DE LA MESA DE PLANCHADO
Loading the manual

®

Page

MODELS AVD40N • AVD40KN • AVD40WN

AVD45N • AVD45KN • AVD45WN • AVD50N

BUILT-IN IRONING CENTER

READ AND SAVE THESE INSTRUCTIONS

INSTALLATION

(Fig. 1)

1. DETERMINE WALL OPENING.

The NuTone Ironing Centers are designed to fit between standard 16” on-center

wall studs. A 49-1/4 ” x 14-1/8 ”x 3-7/8” deep opening is required. 24” on-center

studs will require framing to proper opening size.

2. DETERMINE DISTANCE ABOVE THE FLOOR.

Use the following chart to determine the recommended wall opening above

the floor:

Wall Opening

Working Height

Above the Floor

AVD40/45 Series

AVD50 Series

24”

30”

29”-30½”-32½”

28”

34”

33”-34½”-36½”

30”

36”

35”-36½”-38½”

32”

38”

37”-38½”-40½”

3. ATTACH CLEATS.

Fasten 2x4 cleats to wall studs to provide a level surface on which to rest

cabinet.

4. MOUNT CABINET.

Lift cabinet into place and attach it to studs using the six supplied screws.

Mounting holes positions are indicated by the arrows. On AVD45 and AVD50

Series models, remove the wireway cover to access mounting hole. Be sure to

allow for wall covering thickness behind cabinet face frame. Plumb and shim

cabinet to fit.

5. CONNECT WIRING (Fig. 2)

(AVD45 & AVD50 Series only)

Remove wireway cover. Bring house wiring into cabinet access hole and attach

wiring to cabinet with an approved wire strain relief. Connect black to black,

white to white and green/bare wire from house wiring to ground fixing terminal

at the top end of the cabinet. Replace cover.

WARNING

AVD45 and AVD50 Series Only

ALL ELECTRICAL WORK MUST BE DONE IN ACCORDANCE WITH

LOCAL AND/OR NATIONAL ELECTRICAL CODES AS APPLICABLE.

FOR SAFETY, THIS PRODUCT MUST BE GROUNDED. IF YOU ARE

UNFAMILIAR WITH METHODS OF IN STALLING ELECTRICAL WIRING,

SECURE THE SERVICES OF A QUALIFIED ELECTRICIAN.

The ironing center should be installed on a SEPARATE 15 amp circuit to

prevent circuit overload.

TURN OFF POWER AT SERVICE ENTRANCE BEFORE INSTALLING

WIRING OR SERVICING THIS PRODUCT.

1. Do not place EXCESSIVE WEIGHT (weight should not exceed 30 pounds)

on the ironing board when opened as it is designed to accept normal ironing

use only.

2. Allow iron to cool down before storing in the cabinet.

3. Empty water reservoir and turn off steam action prior to storing iron.

4. Turn power off when not in use.

5. Do not remove the board retainer.

6. The appliance is supplied with approved components and wires which must

not be changed. If any components or wires of this equipment is damaged, it

must only be replaced by the manufacturer, service agent or similarly quali-

fied person in order to avoid hazard.

7. This unit may be installed as a surface mount. If installed in this manner, you

MUST USE the Surface Mount Collar Assembly (AVDSMN). See instructions

included with Assembly, for mounting by this method.

CAUTION: DO NOT ALLOW WIRE TO EX-

TEND OUTSIDE OF WIRING BOX. EXPOSED

WIRES CAN BECOME PINCHED AND ELEC-

TRICAL SHOCK HAZARD MAY RESULT.

Fig. 1

Fig. 2

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - Page; OPERATING INSTRUCTION; MOUNTING THE CABINET DOOR; IRONING BOARD HEIGHT ADJUSTMENT; DO NOT WASH THE COVER

® Page MODELS AVD40N • AVD40KN • AVD40WN AVD45N • AVD45KN • AVD45WN • AVD50N OPERATING INSTRUCTION (Fig. 3) Control Panel (AVD45 and AVD50 Series) SAFETY SWITCH The Ironing Board depresses this switch when placed in its storage position. This disconnects all power to the ironing center controls. TIM...

Page 3 - UNITÉ DE REPASSAGE INTEGRÉ; INSTALLATION; DETERMINEZ LA HAUTEUR AU DESSUS DU SOL.; ATTENTION; Uniquement pour le série AVD45 et AVD50); MODÈLES

® Page MODELS AVD40N • AVD40KN • AVD40WN AVD45N • AVD45KN • AVD45WN • AVD50N UNITÉ DE REPASSAGE INTEGRÉ LISEZ ET CONSERVEZ CES INSTRUCTIONS INSTALLATION (Fig. 1) 1. DETERMINEZ L’EMPLACEMENT DANS LE MUR. Les unités de repassage Broan sont prévues pour être installées entre les montants standards (16i...

Page 4 - INSTRUCTIONS D’UTILISATION; Panneau de Contrôle (Série AVD45 et AVD50); PORTE DE MEUBLE; MONTAGE DE LA PORTE DU MEUBLE; RÉGLAGE DE LA HAUTEUR DE LA

® Page MODELS AVD40N • AVD40KN • AVD40WN AVD45N • AVD45KN • AVD45WN • AVD50N Fig. 3 Fig. 4 Fig. 5 INSTRUCTIONS D’UTILISATION (Fig. 3) Panneau de Contrôle (Série AVD45 et AVD50) INTERRUPTEUR DE SECURITÉ La planche à repasser l’enclenche automatiquement lorsque rangée en fin d’utilisation. Il decon- n...

Other Nutone Models