INSTALLATION INSTRUCTIONS

READ & SAVE THESE INSTRUCTIONS!

®

Automatic Heat Sensor

MODEL: AHS-200

For use with NuTone Attic Ventilators

The NuTone Model AHS-200 is a 200°F heat

sensor and is intended to be installed in the attic
and connected into the power line of a NuTone
Attic Ventilator. In the event the attic
temperature surrounding the heat sensor
reaches 200°F (for any reason, including fire),
the unit will interrupt power to the ventilator
and then will be turned off.
1. Located the heat sensor near the Attic

Ventilator thermostat so that it is up-roof
from the ventilator and thermostat.

2. Mount the heat sensor on the side of a roof

rafter so that it's pointing down toward the
living area of the home.

MODEL AHS-200

THERMOSTAT

AHS-200 BOX

THERMOSTAT BOX

WIRE
CONNECTOR

GREEN GROUND
SCREW

WIRE
CONNECTOR

VENTILATOR

MOTOR

ATTIC

LIVING AREA

ON/OFF SWITCH

120vAC, 60 Hz POWER,
PLUG GROUND

WIRE
CONNECTORS

HEAT
SENSOR

THERMOSTAT

TO 120vAC,
60 Hz

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Was this manual helpful?

About this manual

Brand
Nutone
Model
AHS-200
Document type
Manual
Language(s)
English
Pages
2
File size
331.4 KB
Format
PDF

Ask a question

Up to 3 photos. Max 5 MB each. Formats: JPG, JPEG, PNG, WebP.