An Installation Manual for the Nutone Heat-A-Vent® Combination Model 9905 covers both new construction and existing building setups, focusing on structural planning, ductwork, electrical wiring, and mounting procedures. Key topics include unit dimensions, hardware requirements, step-by-step installation steps, and safety considerations for proper ventilation and electrical connections. The guide emphasizes precise measurements and compatibility with the specific model’s housing and grille assembly.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
Page: / 4

Table of Contents:

  • Page 1 – New Construction Installation Specifications
  • Page 2 – Ceiling-Mounted Unit Installation Procedure
  • Page 3 – Installation in Existing Buildings
  • Page 4 – One Year Limited Warranty Information
Loading the manual
Page 1

INSTALLATION INSTRUCTIONS

READ & SAVE THESE INSTRUCTIONS!

®

Heat-A-Vent

®

Combination

MODEL: 9905

FOR BEST RESULTS

In a new construction site, install the housing (complete

with heater and ventilator) during rough-in construction of
the building. The grille should be installed when the finished
ceiling is in place.

Installation in an existing, finished building requires an

accessible area (attic or crawl space) above the planned
location. See “INSTALLATION IN EXISTING
CONSTRUCTION.”

Do not install closer than 12 inches to a vertical surface.

Do not install over tub or shower enclosure.

UNIT DIMENSIONS

Refer to Figure 1 for housing’s dimensions.

NOTE: If there will be a finished second floor above,

the Model 9905 housing requires a minimum of 2" x 8"
joist construction for mounting.

WIRING AND DUCTWORK

1. Run the required wiring during rough-in stage of construction.
2. Total connected load: 1630 watts.
3. Plan to run 120vAC, 60 Hz wiring (with ground) on a

separate 20 Amp circuit from a power source, through
the provided wall switch, to the housing’s junction box.
See wiring diagram.

4. Use 4" round duct.

INSTALLATION IN
NEW CONSTRUCTION

PREPARATION

1. Loosen hanger bar brackets to allow bars to be inserted.
2. Refer to Figure 2. Insert hanger bars into brackets.
3. Refer to Figure 3. Slide hanger bar brackets down to end

of slot closest to outside edge of housing. Tighten brackets
in this position.

4. Refer to Figure 4. Remove junction box cover by

removing one screw.

5. Refer to Figure 4. Remove appropriate wiring knockout(s)

and install approved box connector(s).

FIGURE 1

FIGURE 2

FIGURE 3

FIGURE 4

7

3

4

"

14"

HANGER BARS

ADJUSTMENT
SLOT

JUNCTION
BOX
COVER

VENT

HEAT

KNOCKOUTS

9

3

4

"

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Was this manual helpful?

About this manual

Brand
Nutone
Model
9905
Document type
Manual
Language(s)
English
Pages
4
File size
106.1 KB
Format
PDF

Summary

Page 1 - New Construction Installation Specifications

Installation instructions, unit dimensions, wiring and ductwork specifications, and preparation steps for installing the Heat-A-Vent® Combination Model 9905 in new construction settings, including diagrams of components.

Page 2 - Ceiling-Mounted Unit Installation Procedure

Step-by-step instructions for mounting a ceiling-mounted heating and ventilation unit, including securing the housing, connecting ductwork, installing the electrical switch, wiring connections, and grille assembly.

Page 3 - Installation in Existing Buildings

Planning requirements for installation in finished buildings, a nine-step process for mounting the unit, connecting utilities, and installing the grille, including cutout dimensions for ceiling openings.

Ask a question

Up to 3 photos. Max 5 MB each. Formats: JPG, JPEG, PNG, WebP.