Nutone 8663RLG - Manual

Nutone 8663RLG

Nutone 8663RLG – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
Page: / 12

Table of Contents:

  • Page 2 – MOUNTING THE HOUSING; FIGURE 2
  • Page 3 – CLEANING AND RELAMPING; FIGURE 5
  • Page 4 – INSTRUCCIONES IMPORTANTES DE SEGURIDAD; No se puede utilizar en recintos de ducha o bañera.; PARA OBTENER MEJORES RESULTADOS; PLANIFICACION DEL CODUCTO Y CABLEADO; FIGURA 1
  • Page 5 – FIGURA 2
  • Page 6 – PARA TERMINAR LA INSTALACTION; FIGURA 5; LIMPIEZA Y CAMBIO DE BOMBILLAS
  • Page 7 – FIGURE 1; INSTRUCTIONS D'INSTALLATION; IMPORTANTES DIRECTIVES DE SÉCURITÉ; INSTRUCTIONS D’INSTALLATION
  • Page 8 – MONTAGE DU BOITIER; INSTALLATION DE LA GAINE; INSTALLATION DU BLOC-MOTEUR
  • Page 9 – POUR FINIR L'INSTALLATION; NETTOYAGE ET REMPLACEMENT DE LA LAMPE
  • Page 11 – PARTS LIST
Loading the manual

INSTALLATION INSTRUCTIONS

READ & SAVE THESE INSTRUCTIONS!

Bathroom Exhaust
Fan/Light
Combination

Suitable for use in insulated ceilings.
WARNING: To reduce the risk of fire or electrical shock, do not
use these fans with any solid-state speed control device. Do not
install in a ceiling insulated to a value greater than R-40.

IMPORTANT SAFETY INSTRUCTIONS

WARNING – TO REDUCE THE RISK OF FIRE, ELECTRIC
SHOCK, OR INJURY TO PERSONS, OBSERVE THE
FOLLOWING:

A. Use this unit only in the manner intended by the manufacturer. If

you have questions, contact the manufacturer.

B. Before servicing or cleaning unit, switch power off at Service

Panel and lock Service Panel to prevent power from being
switched on accidentally.
When the service disconnecting means cannot be locked,
securely fasten a prominent warning device, such as a tag, to the
service panel.

CAUTION:

For general ventilating use only. Do not use to exhaust

hazardous or explosive materials and vapors.

INSTALLATION INSTRUCTIONS

WARNING – TO REDUCE THE RISK OF FIRE, ELECTRIC
SHOCK, OR INJURY TO PERSONS, OBSERVE THE
FOLLOWING:

A. Installation work and electrical wiring must be done by qualified

person(s) in accordance with all applicable codes and standards,
including fire-rated construction.

B. Sufficient air is needed for proper combustion and exhausting of

gases through the flue (chimney) of fuel burning equipment to
prevent back drafting. Follow the heating equipment
manufacturer's guideline and safety standards such as those
published by the National Fire Protection Association (NFPA), and
the American Society for Heating, Refrigeration and Air
Conditioning Engineers (ASHRAE), and the local code authorities.

C. When cutting or drilling into wall or ceiling, do not damage

electrical wiring and other hidden utilities.

D. Ducted fans must always be vented to the outdoors.
E. If this unit is to be installed over a tub or shower, it must be

marked as appropriate for the application.

F. NEVER place a switch where it can be reached from a tub or

shower.

MODEL: 8663RLG

Suitable for use over tub or shower enclosure when
installed in a GFI protected branch circuit.

FOR BEST RESULTS

When installing the Exhaust Fan/Light in a new construction site,

install housing during the rough-in construction of the building. The
blower unit, reflector and grille should be installed after the finished
ceiling is in place.

PLANNING DUCTWORK AND WIRING

1. Use 4" round duct.
2. Plan duct run from discharge opening of fan to the outside. For

best fan performance, make duct run as short as possible and
use minimum number of elbows.

3. Use optional NuTone ducting accessories as needed.

IMPORTANT:

Use wire suitable for 90°C.

Plan to run 120vAC house wiring (with ground) from power source,

through wall switches, to junction box in fan. For separate control of
fan, light, and night light three wall switches are required. See
NuTone Catalog for accessory switches. For separate control of fan,
light, and night light, five conductors are needed between the wall
switch box and the fan's junction box.

Wiring
Knockouts

FIGURE 1

Housing

Scroll

Slots

Power/Blower

Unit

Reflector
Assembly

Night
Light
Socket

Wing Nut

Grille/Lens

Assembly

Mounting

Springs (2)

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - MOUNTING THE HOUSING; FIGURE 2

INSTALLATION IN A NEWCONSTRUCTION SITE PREPARATION 1. Refer to Figure 1. Remove power unit/blower assembly from housing. A. Unplug power unit.B. Remove screw (located next to plug-in receptacle) which holds power/blower unit mounting plate in place. Save screw. C. Lift mounting plate at end near the...

Page 3 - CLEANING AND RELAMPING; FIGURE 5

COMPLETING INSTALLATION 1. Insert lamp plug into junction box receptacle and secure reflector assembly to motor frame with wing nut provided. 2. Install lamps 100 watt (maximum) for light, and 7 watt (maximum) for night light. 3. Squeezing the grille assembly's mounting springs together, insert spri...

Page 4 - INSTRUCCIONES IMPORTANTES DE SEGURIDAD; No se puede utilizar en recintos de ducha o bañera.; PARA OBTENER MEJORES RESULTADOS; PLANIFICACION DEL CODUCTO Y CABLEADO; FIGURA 1

INSTRUCCIONES DE INSTALACION ¡LEA Y GUARDE ESTAS INSTRUCCIONES! Combinación delámpara/ventiladoraspirante paracuartos de baño El ventilador aspirante consiste de la caja, el montaje de unidad de potencia/soplador (motor, ruede, placa de montaje), rejilla, conjuntodel portalámparas de reflector/lámpa...

Other Nutone Models