National Instruments SCXI-1503 - Manual

National Instruments SCXI-1503

National Instruments SCXI-1503 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
29 Page 29
30 Page 30
31 Page 31
32 Page 32
33 Page 33
34 Page 34
35 Page 35
36 Page 36
37 Page 37
38 Page 38
39 Page 39
40 Page 40
41 Page 41
42 Page 42
43 Page 43
44 Page 44
45 Page 45
46 Page 46
47 Page 47
48 Page 48
49 Page 49
50 Page 50
51 Page 51
52 Page 52
53 Page 53
54 Page 54
55 Page 55
56 Page 56
57 Page 57
58 Page 58
59 Page 59
60 Page 60
61 Page 61
62 Page 62
63 Page 63
64 Page 64
65 Page 65
66 Page 66
67 Page 67
68 Page 68
69 Page 69
70 Page 70
71 Page 71
72 Page 72
73 Page 73
74 Page 74
75 Page 75
76 Page 76
77 Page 77
78 Page 78
79 Page 79
Page: / 79

Table of Contents:

  • Page 3 – Important Information; Warranty; Patents; WARNING REGARDING USE OF NATIONAL INSTRUMENTS PRODUCTS
  • Page 4 – Conventions; File»Page Setup»Options; bold
  • Page 5 – Contents
  • Page 7 – Glossary
  • Page 8 – Tables
  • Page 9 – What You Need to Get Started
  • Page 10 – National Instruments Documentation
  • Page 11 – Drivers and Updates
  • Page 12 – Installing the SCXI-1503 Module into the SCXI Chassis; Installing the Terminal Block; Configuring the SCXI System Software; Terminal Block
  • Page 13 – Verifying the SCXI-1503 Installation
  • Page 14 – Connecting Signals; Analog Input Signal Connections
  • Page 15 – Ground-Referencing the Signals; Connecting Resistive Devices to the SCXI-1503
  • Page 22 – Pin
  • Page 23 – Rear Signal Connector
  • Page 24 – Rear Signal Connector Descriptions
  • Page 26 – Configuring and Testing; Common Software-Configurable Settings
  • Page 27 – Input Coupling; Configurable Settings in MAX
  • Page 28 – Creating a Global Channel or Task
  • Page 29 – Verifying the Signal; Verifying the Signal in NI-DAQmx Using a Task or Global Channel
  • Page 30 – Test; Start; Stop
  • Page 31 – Theory of Operation
  • Page 33 – Digital Control Circuitry; Analog Input Channels
  • Page 34 – Operation of the Current Sources; Theory of Multiplexed Operation
  • Page 35 – Measuring Temperature with Resistive Transducers; RTDs
  • Page 36 – RTD Measurement Errors
  • Page 40 – Thermistors
  • Page 41 – Thermistor Measurement Circuits
  • Page 44 – Developing Your Application in NI-DAQmx; Typical Program Flowchart
  • Page 46 – General Discussion of Typical Flowchart
  • Page 47 – Configuring Channel Properties
  • Page 51 – Completing the Application; Developing an Application Using LabVIEW
  • Page 54 – Specifying Channel Strings in NI-DAQmx
  • Page 56 – Programmable NI-DAQmx Properties; Calibration; External Calibration
  • Page 57 – Manual Calibration
  • Page 58 – Analog Input
  • Page 60 – Dynamic Characteristics; Filter
  • Page 61 – Excitation
  • Page 62 – Physical
  • Page 63 – Safety; Electromagnetic Compatibility; CE Compliance; Waste Electrical and Electronic Equipment (WEEE)
  • Page 64 – Removing the SCXI-1503 from MAX; Devices and Interfaces; Removing the SCXI-1503 from a Chassis
  • Page 66 – Common Questions; Download Software»Drivers and Updates»Search Drivers and; How can I ground a floating voltage measurement?
  • Page 67 – Can I connect
  • Page 69 – Symbol
  • Page 76 – Index; Numerics
Loading the manual

SCXI

TM

SCXI-1503 User Manual

March 2007
374271A-01

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 3 - Important Information; Warranty; Patents; WARNING REGARDING USE OF NATIONAL INSTRUMENTS PRODUCTS

Important Information Warranty The SCXI-1503 is warranted against defects in materials and workmanship for a period of one year from the date of shipment, as evidenced by receipts or other documentation. National Instruments will, at its option, repair or replace equipment that proves to be defectiv...

Page 4 - Conventions; File»Page Setup»Options; bold

Conventions The following conventions are used in this manual: < > Angle brackets that contain numbers separated by an ellipsis represent a range of values associated with a bit or signal name—for example, P0.<3..0>. » The » symbol leads you through nested menu items and dialog box optio...

Page 5 - Contents

© National Instruments Corporation v SCXI-1503 User Manual Contents Chapter 1About the SCXI-1503 What You Need to Get Started ...................................................................................... 1-1National Instruments Documentation ....................................................

Other National Instruments Models

All National Instruments Other