Page 2 - Dimensions; Note
NI USB-9237 User Guide and Specifications 2 ni.com Dimensions Figure 2 shows the NI USB-9237 device dimensions. Figure 2. NI USB-9237 Device in Millimeters (Inches) Safety Guidelines Operate the NI USB-9237 only as described in these operating instructions. Note Although the NI 9237 module may have ...
Page 3 - Related Documentation; LabVIEW
© National Instruments Corporation 3 NI USB-9237 User Guide and Specifications Related Documentation Each application software package and driver includes information about writing applications for taking measurements and controlling measurement devices. The following references to documents assume ...
Page 4 - Taking an; Measurement Studio; DAQ
NI USB-9237 User Guide and Specifications 4 ni.com • Taking Measurements —Contains the conceptual and how-to information you need to acquire and analyze measurement data in LabVIEW, including common measurements, measurement fundamentals, NI-DAQmx key concepts, and device considerations. LabWindows/...
Page 5 - ANSI C without NI Application Software; NI-DAQmx C Reference Help; .NET Languages without NI Application Software
© National Instruments Corporation 5 NI USB-9237 User Guide and Specifications ANSI C without NI Application Software The NI-DAQmx Help contains API overviews and general information about measurement concepts. Select Start»All Programs»National Instruments»NI-DAQ»NI-DAQmx Help . The NI-DAQmx C Refe...
Page 6 - Training Courses; DAQ Getting Started Guide; Installing Other Software; USB Devices Getting Started Guide; Start»All Programs»National Instruments»; Installing the NI USB-9237 Device; Installing the Software
NI USB-9237 User Guide and Specifications 6 ni.com Training Courses If you need more help getting started developing an application with NI products, NI offers training courses. To enroll in a course or obtain a detailed course outline, refer to ni.com/training . Technical Support on the Web For add...
Page 8 - Mounting the NI USB-9237 to a Panel; Connecting the NI USB-9237 to a Computer; Devices Getting Started Guide; Start»All Programs»National Instruments»NI-DAQ; for more information.; LED Indicator
NI USB-9237 User Guide and Specifications 8 ni.com Mounting the NI USB-9237 to a Panel Threaded inserts are located in the NI USB-9237 for mounting it to a panel. Refer to Figure 5 for dimensions. Figure 5. Module Dimensions in Millimeters (Inches) Connecting the NI USB-9237 to a Computer Plug one e...
Page 9 - Wiring the NI USB-9237 Device; LED State; Specifications
© National Instruments Corporation 9 NI USB-9237 User Guide and Specifications Wiring the NI USB-9237 Device The NI USB-9237 has four RJ-50 receptacles that provide connections for four half or full bridges. Table 2 lists the signal names of the terminals for each connector, and shows the correlatio...
Page 10 - Caution
NI USB-9237 User Guide and Specifications 10 ni.com Caution National Instruments does not recommend using an RJ-45 with the NI USB-9237 because it can physically damage pins 1 and 10 on the device, and thus permanently disable shunt calibration no matter what connector you use. Table 2. Terminal Ass...
Page 11 - Connecting Loads to the NI USB-9237
© National Instruments Corporation 11 NI USB-9237 User Guide and Specifications Figure 6. Four Position External Excitation Voltage Source Connection Connecting Loads to the NI USB-9237 Refer to Figure 7 for an illustration of how to connect full and half bridges to the NI USB-9237. Figure 7. Half- ...
Page 12 - Wiring TEDS Channels; and; for information about TEDS sensors.; NI USB-9237 Connection Options; Figure 8 shows a diagram of how the NI USB-9237 uses remote sensing.
NI USB-9237 User Guide and Specifications 12 ni.com Completion Accessories for more information about these accessories and how to purchase them. Wiring TEDS Channels Ensure that neither the TEDS data (T+) nor the TEDS return (T–) is tied in common to any AI signals on the NI USB-9237. Visit ni.com/...
Page 13 - Shunt Calibration; resistor and a software-controlled switch. You can leave the shunt
© National Instruments Corporation 13 NI USB-9237 User Guide and Specifications As shown in Figure 8, the actual bridge excitation voltage is smaller than the voltage at the EX+ and EX– leads. If remote sensing of the actual bridge voltage is not used, the resulting gain error is for full-bridge sen...
Page 14 - Excitation Voltages
NI USB-9237 User Guide and Specifications 14 ni.com Excitation Voltages Although the sensor industry does not recognize a single standard excitation voltage level, excitation voltage levels of between 2.5 V and 10 V are common. You can program the NI USB-9237 to supply 2.5 V, 3.3 V, 5 V, or 10 V of ...
Page 15 - Understanding NI USB-9237 Filtering
© National Instruments Corporation 15 NI USB-9237 User Guide and Specifications Each channel on the NI USB-9237 has an independent 24-bit ADC and input amplifier that enable you to sample signals from all four channels simultaneously. The NI USB-9237 also includes filters to prevent aliasing. The fi...
Page 16 - Stopband; The following specifications are typical for the range; Input Characteristics; Bridge completion
NI USB-9237 User Guide and Specifications 16 ni.com Stopband The filter significantly attenuates all signals above the stopband frequency. The primary goal of the filter is to prevent aliasing. Therefore, the stopband frequency scales precisely with the data rate. The stopband rejection is the minim...
Page 17 - Accuracy
© National Instruments Corporation 17 NI USB-9237 User Guide and Specifications Overvoltage protectionbetween any two terminals ..................... ± 30 V Accuracy Gain drift ................................................ 10 ppm/°C max Offset drift 2.5 V excitation .................................
Page 18 - Excitation; per
NI USB-9237 User Guide and Specifications 18 ni.com Stopband Frequency ........................................0.55 · f s Rejection ..........................................100 dB Alias-free bandwidth ..............................0.45 · f s Oversample rate ......................................64 ...
Page 19 - Power Requirements
© National Instruments Corporation 19 NI USB-9237 User Guide and Specifications Crosstalk 1 kHz ............................................... 110 dB 10 kHz ............................................. 100 dB Shunt calibration Resistance ....................................... 100 k Ω Resistor acc...
Page 20 - Safety Standards; Hazardous Locations
NI USB-9237 User Guide and Specifications 20 ni.com Isolation Channel-to-channel..........................No isolation between channels Channel-to-earth ground Continuous ...............................60 VDC, Measurement Category I Withstand .................................1,000 V rms , verified b...
Page 21 - noncondensing; Electromagnetic Compatibility; EN 61326 EMC requirements Minimum Immunity; CE Compliance
© National Instruments Corporation 21 NI USB-9237 User Guide and Specifications Operating humidity(IEC 60068-2-56) ................................... 10 to 90% RH, noncondensing Storage humidity(IEC 60068-2-56) ................................... 5 to 95% RH, noncondensing Maximum altitude ...........
Page 22 - Environmental Management; NI and the; Waste Electrical and Electronic Equipment (WEEE); EU Customers; Calibration; ⬉ᄤֵᙃѻક∵ᵻࠊᄣ⧚ࡲ⊩ ˄Ё; RoHS
NI USB-9237 User Guide and Specifications 22 ni.com Environmental Management National Instruments is committed to designing and manufacturing products in an environmentally responsible manner. NI recognizes that eliminating certain hazardous substances from our products is beneficial not only to the...
Page 23 - Where to Go for Support; you have access to everything from
National Instruments, NI, ni.com, and LabVIEW are trademarks of National Instruments Corporation. Refer to the Terms of Use section on ni.com/legal for more information about National Instruments trademarks. Other product and company names mentioned herein are trademarks or trade names of their resp...