Page 3 - Important Information; Warranty; Patents; WARNING REGARDING USE OF NATIONAL INSTRUMENTS PRODUCTS
Important Information Warranty The FBUS-HSE/H1 Linking Device (LD) is warranted against defects in materials and workmanship for a period of one year from the date of shipment, as evidenced by receipts or other documentation. National Instruments will, at its option, repair or replace equipment that...
Page 4 - Compliance; FCC/Canada Radio Frequency Interference Compliance; Determining FCC Class; Class A; Federal Communications Commission; Compliance to EU Directives
Compliance FCC/Canada Radio Frequency Interference Compliance Determining FCC Class The Federal Communications Commission (FCC) has rules to protect wireless communications from interference. The FCC places digital electronics into two classes. These classes are known as Class A (for use in industri...
Page 5 - Contents; About This Manual
© National Instruments Corporation v FBUS-HSE/H1 LD User Manual Contents About This Manual How To Use the Manual Set .......................................................................................... viiConventions ................................................................................
Page 6 - Glossary
Contents FBUS-HSE/H1 LD User Manual vi ni.com Appendix DTechnical Support and Professional Services Glossary Index
Page 7 - How To Use the Manual Set; Conventions; File»Page Setup»Options
© National Instruments Corporation vii FBUS-HSE/H1 LD User Manual About This Manual This manual describes the mechanical and electrical aspects of the FBUS-HSE/H1 Linking Device (LD) and contains information concerning its installation and operation. The FBUS-HSE/H1 LD product is a High Speed Ethern...
Page 8 - Related Documentation
About This Manual FBUS-HSE/H1 LD User Manual viii ni.com programs, subprograms, subroutines, device names, functions, operations, variables, filenames and extensions, and code excerpts. Related Documentation The following documents contain information you might find helpful as you read this manual: ...
Page 9 - Product Overview
© National Instruments Corporation 1-1 FBUS-HSE/H1 LD User Manual 1 Overview of FBUS-HSE/H1 Linking Device (LD) Hardware This chapter provides an overview of the FBUS-HSE/H1 Linking Device (LD) hardware. Product Overview High Speed Ethernet (HSE) is an extension to the Foundation Fieldbus specificat...
Page 10 - Configuration and Monitoring
Chapter 1 Overview of FBUS-HSE/H1 Linking Device (LD) Hardware FBUS-HSE/H1 LD User Manual 1-2 ni.com Figure 1-1 shows an FBUS-HSE/H1 LD connected to an Ethernet network. Figure 1-1. Typical Ethernet Network Setup In a distributed application, many Fieldbus H1 segments are networked together using HS...
Page 11 - System Requirements; STATUS
Chapter 1 Overview of FBUS-HSE/H1 Linking Device (LD) Hardware © National Instruments Corporation 1-3 FBUS-HSE/H1 LD User Manual Once configured, the linking device permits HMI software on any PC connected to an FBUS-HSE/H1 LD to access and monitor Fieldbus devices as if the HMI were directly connec...
Page 15 - Connect Your FBUS-HSE/H1 LD to the Network
Chapter 2 Hardware Installation and Configuration FBUS-HSE/H1 LD User Manual 2-4 ni.com Connect Your FBUS-HSE/H1 LD to the Network Connect the RJ-45 Ethernet port of the FBUS-HSE/H1 LD to an Ethernet hub using a standard Category 5 Ethernet cable. You also can connect an FBUS-HSE/H1 LD directly to a...
Page 16 - Cabling; Pin
Chapter 2 Hardware Installation and Configuration © National Instruments Corporation 2-5 FBUS-HSE/H1 LD User Manual Cabling If you build your own cables, the following table shows the standard Ethernet cable wiring connections for both normal and crossover cables. Figure 2-5 shows the connector pino...
Page 17 - Connect the FBUS-HSE/H1 LD to the Fieldbus Network
Chapter 2 Hardware Installation and Configuration FBUS-HSE/H1 LD User Manual 2-6 ni.com Connect the FBUS-HSE/H1 LD to the Fieldbus Network The FBUS-HSE/H1 LD can be one of up to 32 devices connected to a Fieldbus H1 network. The connection is made through one of the two 9-pin male D-sub Fieldbus H1 ...
Page 18 - POWER
Chapter 2 Hardware Installation and Configuration © National Instruments Corporation 2-7 FBUS-HSE/H1 LD User Manual Connect Power to the FBUS-HSE/H1 LD Each FBUS-HSE/H1 LD on your network requires an 11-30 VDC power supply. The power connector is a 6-pin screw terminal power connector whose pinout i...
Page 21 - Troubleshooting; LED Indicators; Hardware
© National Instruments Corporation B-1 FBUS-HSE/H1 LD User Manual B Troubleshooting LED Indicators Hardware The FBUS-HSE/H1 LD has seven LED indicators on the top panel and three LEDs on the front panel, as shown in Figure B-1.
Page 22 - Ethernet LEDs
Appendix B Troubleshooting FBUS-HSE/H1 LD User Manual B-2 ni.com Figure B-1. LEDs on the FBUS-HSE/H1 LD Ethernet LEDs The six Ethernet LEDs are located on the top panel. The green POWER LED is lit while the FBUS-HSE/H1 LD is powered up. This LED indicates that the power supply connected to the FBUS-...
Page 24 - Module STATUS LED
Appendix B Troubleshooting FBUS-HSE/H1 LD User Manual B-4 ni.com Module STATUS LED The module STATUS LED is located on the front of the linking device, between the two Fieldbus (H1 Network) connectors, as shown in Figure B-1. It indicates whether the linking device is powered, configured, and operat...
Page 25 - H1 Network Status LEDs; LED State
Appendix B Troubleshooting © National Instruments Corporation B-5 FBUS-HSE/H1 LD User Manual Standby state indicates the linking device has passed all self tests and is ready to operate. However, it is not functioning because no active Ethernet segment is configured. Operational state indicates the ...
Page 26 - Specifications; Network; Operating Environment
© National Instruments Corporation C-1 FBUS-HSE/H1 LD User Manual C Specifications This appendix describes the specifications of the FBUS-HSE/H1 LD. Network Network interface ................................... 10BaseT and 100BaseTX Ethernet Device interface ..................................... Fou...
Page 27 - Safety; Electromagnetic Compatibility; CE Compliance; Declarations
Appendix C Specifications FBUS-HSE/H1 LD User Manual C-2 ni.com Safety This product is designed to meet the requirements of the following standards for safety and electrical equipment for measurement, control, and laboratory use: • IEC 60950, EN 60950 • UL 1950, UL 60950 • CAN/CSA C22.2 No. 60950 No...
Page 29 - Calibration Certificate
Appendix D Technical Support and Professional Services FBUS-HSE/H1 LD User Manual D-2 ni.com • Calibration Certificate —If your product supports calibration, you can obtain the calibration certificate for your product at ni.com/calibration . If you searched ni.com and could not find the answers you ...
Page 30 - Symbol
© National Instruments Corporation G-1 FBUS-HSE/H1 LD User Manual Glossary Symbol Prefix Value m milli 10 – 3 k kilo 10 3 M mega 10 6 A A Amperes. A/D Analog-to-digital converter Alarm. A notification the NI-FBUS Communications Manager software sends when it detects that a block leaves or returns to...
Page 38 - Index
© National Instruments Corporation I-1 FBUS-HSE/H1 LD User Manual Index C cables, 2-5calibration certificate, D-2CE compliance, C-2compatibility information, 1-3configuration and monitoring, 1-2connecting to the Fieldbus network, 2-6connector pinout (figure), 2-6contacting National Instruments, D-2c...