National Instruments CFP-CTR-502 - Manual

National Instruments CFP-CTR-502

National Instruments CFP-CTR-502 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
Page: / 22

Table of Contents:

  • Page 3 – Using a number 2 Phillips screwdriver with a shank of at least; terminals are all internally connected, as are the C and COM
  • Page 4 – terminal on each channel. Install; Channel Name; or V; COM
  • Page 5 – Inputs; sourcing
  • Page 6 – Note; must; Outputs; sinking
  • Page 7 – terminal by the external device must not exceed the voltage
  • Page 8 – Configuring Count-Input Channels; Terminal Count; Configuring Output Channels; Channel Status; Count Source
  • Page 9 – Gate Source; Read Reset Mode
  • Page 10 – Increment; Configuring Gate-Input Channels; Output Source; Counter Channel 0 –7
  • Page 11 – Output Mode; On Pulse; . The output modes work only if you select; for the; sections describe the different output modes.
  • Page 12 – Off Pulse
  • Page 13 – Step 1. Set Up the Prescaler Counter; Step 2. Set Up the Pulse Counter; Always Enabled
  • Page 14 – term; Previous Channel; Don’t Reset; t e r m
  • Page 15 – Step 3. Configure the Pulse Train Output Channel; the Pulse Counter
  • Page 16 – Upgrading the FieldPoint Firmware; Isolation and Safety Guidelines; Caution
  • Page 17 – not
  • Page 18 – Specifications; Input Characteristics; Output Characteristics
  • Page 19 – Physical Characteristics; POWER; Power Requirements; Environmental
  • Page 20 – Shock and Vibration; Safety; FCC Part 15A above 1 GHz; For EMC compliance, you
  • Page 21 – CE Compliance; Refer to the Declaration of Conformity (DoC) for; Declarations of Conformity Information; at; Mechanical Dimensions
  • Page 22 – Where to Go for Support
Loading the manual

323324B-01

June 2003

©

2002–2003 National Instruments Corp. All rights reserved.

FieldPoint™, National Instruments™, NI™, and ni.com™ are trademarks of National Instruments Corporation.
Product and company names mentioned herein are trademarks or trade names of their respective companies.
For patents covering National Instruments products, refer to the appropriate location:

Help»Patents

in your software,

the

patents.txt

file on your CD, or

ni.com/patents

.

FieldPoint Operating Instructions

FP-CTR-502 and
cFP-CTR-502

Eight-Channel, 16-Bit Counter Module

These operating instructions describe how to install and use the
National Instruments FP-CTR-502 and cFP-CTR-502 counter
modules (referred to inclusively as the [c]FP-CTR-502). For
information about configuring and accessing the [c]FP-CTR-502
over a network, refer to the user manual for the FieldPoint network
module you are using.

Features

The [c]FP-CTR-502 is a FieldPoint counter module with the
following features:

Eight 16-bit counters with individual count-input terminals

Four gate-input channels configurable as either gates or digital
inputs

Four output channels configurable as either generic digital
outputs or associated outputs for the count-input channels

5–30 VDC sourcing inputs and sinking outputs, compatible
with TTL devices and other 5, 12, and 24 VDC devices

Internal frequency references of 1 kHz and 32 kHz

Internally cascadable counters

Software-enabled 50 kHz or 200 Hz lowpass filter on
count-input channels

On/Off LED indicators

2,300 V

rms

transient overvoltage protection

Hot swappable

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 3 - Using a number 2 Phillips screwdriver with a shank of at least; terminals are all internally connected, as are the C and COM

© National Instruments Corp. 3 FP-CTR-502 and cFP-CTR-502 2. Press firmly to seat the cFP-CTR-502 on the backplane. 3. Using a number 2 Phillips screwdriver with a shank of at least 64 mm (2.5 in.) length, tighten the captive screws to 1.1 N ⋅ m (10 lb ⋅ in.) of torque. The nylon coating on the scre...

Page 4 - terminal on each channel. Install; Channel Name; or V; COM

FP-CTR-502 and cFP-CTR-502 4 ni.com Use a 5–30 VDC external power supply for the input channels. The power supply must provide enough current to power all of the input channels and all of the field devices on the output channels. Connect the external power supply to multiple V and V SUP terminals an...

Page 5 - Inputs; sourcing

© National Instruments Corp. 5 FP-CTR-502 and cFP-CTR-502 Inputs Each input channel has one input terminal, V IN . Each channel also has V SUP and COM terminals that can supply power to field devices or provide additional connections to the external power supply. You can connect the eight count-inpu...