National Instruments 5441 - Manual

National Instruments 5441

National Instruments 5441 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
29 Page 29
30 Page 30
31 Page 31
32 Page 32
33 Page 33
34 Page 34
35 Page 35
36 Page 36
37 Page 37
38 Page 38
39 Page 39
40 Page 40
41 Page 41
42 Page 42
43 Page 43
44 Page 44
Page: / 44

Table of Contents:

  • Page 3 – Amplitude and Offset
  • Page 5 – Frequency and Transient Response; Specification
  • Page 14 – Sample Clock
  • Page 17 – Onboard Clock
  • Page 18 – CLK IN; (Sample Clock and Reference Clock Input, Front Panel Connector)
  • Page 19 – PFI 0 and PFI 1
  • Page 20 – Optional Front Panel Connector
  • Page 21 – Output Signal Characteristics (Continued)
  • Page 22 – Start Trigger
  • Page 24 – Markers; NI Signal Generators
  • Page 25 – Arbitrary Waveform Generation Mode
  • Page 27 – Waveform Play Times
  • Page 28 – Function Generation Mode
  • Page 29 – Onboard Signal Processing; Pre-Filter Gain and Offset
  • Page 39 – Software
  • Page 40 – Environment; Specifications
  • Page 42 – Physical
  • Page 43 – Technical Support Resources; NI Web Support
Loading the manual

NI 5441 Specifications

NI PXI-5441 16-Bit 100 MS/s Arbitrary Waveform Generator
with Onboard Signal Processing (OSP)

Unless otherwise noted, the following conditions were used for each
specification:

Analog Filter enabled.

DAC Interpolation set to maximum allowed factor for a given sample
rate.

Signals terminated with 50

.

Direct Path set to 1 V

pk-pk

, Low-Gain Amplifier Path set to 2 V

pk-pk

,

and High-Gain Amplifier Path set to 12 V

pk-pk

.

Sample clock set to 100 MS/s.

Typical values are representative of an average unit operating at room
temperature (25 °C ± 3 °C). Specifications are subject to change without
notice. For the most recent NI 5441 specifications, visit

ni.com/manuals

.

To access all the NI 5441 documentation, including the

NI Signal

Generators Getting Started Guide

, which contains functional descriptions

of the NI 5441 signals, navigate to

Start»Programs»National

Instruments»NI-FGEN»Documentation

.

Hot Surface

If the NI 5441 has been in use, it may exceed safe handling temperatures and

cause burns. Allow the NI 5441 to cool before removing it from the chassis.

Contents

CH 0 ........................................................................................................ 2
Sample Clock .......................................................................................... 14
Onboard Clock ........................................................................................ 17
Phase-Locked Loop (PLL) Reference Clock .......................................... 17
CLK IN ................................................................................................... 18
PFI 0 and PFI 1 ....................................................................................... 19
DIGITAL DATA & CONTROL (DDC) ................................................ 20
Start Trigger ............................................................................................ 22
Markers ................................................................................................... 24

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 3 - Amplitude and Offset

© National Instruments Corporation 3 NI 5441 Specifications Amplitude and Offset Amplitude Range Path Load Amplitude (V pk-pk ) 1. Amplitude values assume the full scale of the DAC is utilized. If an amplitude smaller than the minimum value is desired, then waveforms less than full scale of the DAC ...

Page 5 - Frequency and Transient Response; Specification

© National Instruments Corporation 5 NI 5441 Specifications Frequency and Transient Response Bandwidth 43 MHz Measured at –3 dB. DAC Digital Interpolation Filter Software-selectable Finite Impulse Response (FIR) filter. Available interpolation factors are 2, 4, or 8. Refer to the Onboard Signal Proc...

Page 14 - Sample Clock

NI 5441 Specifications 14 ni.com Figure 6. Direct Path, 2-Tone Spectrum (Typical) Note The noise floor in Figure 6 is limited by the measurement device. Refer to the Average Noise Density specifications. Sample Clock Specification Value Comments Sources 1. Internal, Divide-by- N ( N ≥ 1) 2. Internal...

Other National Instruments Models