National Instruments 12-Bit 200 MS/s Digitizer - Manual

National Instruments 12-Bit 200 MS/s Digitizer

National Instruments 12-Bit 200 MS/s Digitizer – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
29 Page 29
30 Page 30
31 Page 31
32 Page 32
Page: / 32

Table of Contents:

  • Page 2 – Vertical; Specification
  • Page 3 – Voltage Levels; Accuracy
  • Page 13 – Horizontal; Sample Clock
  • Page 15 – External Sample Clock
  • Page 17 – Trigger
  • Page 21 – TClk Specifications
  • Page 22 – Waveform Specifications
  • Page 23 – Calibration
  • Page 24 – Software
  • Page 25 – Environment
  • Page 27 – Safety; CE Compliance
  • Page 28 – Environmental Management; Waste Electrical and Electronic Equipment (WEEE); Physical; Front Panel Connectors; ⬉ᄤֵᙃѻક∵ᵻ᥻ࠊᄣ⧚ࡲ⊩ ˄Ё೑; RoHS
  • Page 29 – Dimensions and Weight; NI PXI-5124 Front Panel Indicators
  • Page 31 – Where to Go for Support
Loading the manual

NI PXI/PCI-5124 Specifications

12-Bit 200 MS/s Digitizer

This document lists the specifications for the NI PXI/PCI-5124 (NI 5124)
high-speed digitizer. Unless otherwise noted, these specifications are valid
for the following conditions:

All filter settings

All impedance selections

Sample clock set to 200 MS/s using onboard clock

Typical values are representative of an average unit operating at room
temperature. Specifications are subject to change without notice. For the
most recent NI 5124 specifications, visit

ni.com/manuals

.

To access the NI 5124 documentation, including the

NI High-Speed

Digitizers Getting Started Guide

, which contains functional descriptions

of the NI 5124 signals, navigate to

Start»All Programs»National

Instruments»NI-SCOPE»Documentation

.

Hot Surface

If the NI 5124 has been in use, it may exceed safe handling temperatures and

cause burns. Allow the NI 5124 to cool before removing it from the PXI chassis or PC.
Refer to the

Environment

section for operating temperatures of this device.

Contents

Vertical .................................................................................................... 2

Analog Input (Channel 0 and Channel 1) ........................................ 2

Horizontal................................................................................................ 13

Sample Clock ................................................................................... 13
Phase-Locked Loop (PLL) Reference Clock ................................... 16
CLK IN (Sample Clock and Reference Clock Input,

Front Panel Connector) ................................................................. 17

CLK OUT (Sample Clock and Reference Clock Output,

Front Panel Connector) ................................................................. 17

Trigger ..................................................................................................... 17

Reference (Stop) Trigger ................................................................. 17
TRIG (External Trigger, Front Panel Connector) ............................ 19

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - Vertical; Specification

NI PXI/PCI-5124 Specifications 2 ni.com PFI 0 and PFI 1 (Programmable Function Interface, AUX Front Panel Connector) ...............................................................20 TClk Specifications .................................................................................21Waveform Speci...

Page 3 - Voltage Levels; Accuracy

© National Instruments Corporation 3 NI PXI/PCI-5124 Specifications Voltage Levels Full Scale (FS) Input Range and Programmable Vertical Offset 50 Ω 1 M Ω — Range (V pk-pk ) Vertical Offset Range (V) Range (V pk-pk ) Vertical Offset Range (V) 0.2 ±0.1 0.2 ±0.1 0.4 ±0.2 0.4 ±0.2 1 ±0.5 1 ±0.5 2 ±1 2 ...

Page 13 - Horizontal; Sample Clock

© National Instruments Corporation 13 NI PXI/PCI-5124 Specifications Horizontal Sample Clock Specification Value Comments Sources NI PXI-5124 NI PCI-5124 * Internal Sample Clock is locked to the Reference Clock or derived from the onboard VCXO Internal, Onboard Clock (internal VCXO) * External, CLK ...

Other National Instruments Models

All National Instruments Other