Napoleon ZCVF36 - Manual
Napoleon ZCVF36 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 2 – WARNING; TABLE of CONTENTS; PLEASE RETAIN THIS MANUAL FOR FUTURE REFERENCE; REPLACEMENTS
- Page 3 – NAPOLEON GAS FIREPLACE PRESIDENT’S LIFETIME LIMITED WARRANTY; rebox enclosure are warranted against defects for as long as you; CONDITIONS AND LIMITATIONS
- Page 4 – Warning: Do not operate without hood in place.; SPECIFICATIONS; FIGURE 1
- Page 5 – ) identify the preferred inlet and remove corresponding knock; GAS INLET LOCATIONS
- Page 6 – FRAMING; FIGURE 3; sides, back, bottom and top of the unit
- Page 7 – FIGURE 6c; * Additional set screws may be installed.; NAILING TAB INSTRUCTION; FIGURE 7
- Page 8 – OPTIONAL BLOWER INSTALLATION
- Page 9 – WITH THERMAL SWITCH BRACKET; FIGURE 9; THERMAL DISC; FIGURE 9
- Page 10 – REPLACEMENTS; FOR WARRANTY REPLACEMENT PARTS, A; REPLACEMENT PARTS
- Page 11 – This fireplace must be serviced annually depending on usage.
- Page 12 – NOTES
1
W415-0527/ 09.29.05
INSTALLER: THESE INSTRUCTIONS MUST BE CONVEYED TO AND REMAIN WITH THE HOMEOWNER.
• Do not try to light any appliance.
• Do not touch any electrical switch.
• Do not use any phone in your
building.
ZERO CLEARANCE VENTLESS FIREBOX ENCLOSURE
MODEL
ZCVF36
MODEL
ZCVF42
CERTIFIED FOR UNITED STATES USING ANSI METHODS
WARNING:
If the information in these instructions is not followed exactly, a fi re or
explosion may result causing property damage, personal injury or death.
FOR YOUR SAFETY
Do not store or use gasoline or other fl ammable vapours and liquids in the vicinity of
this or any other appliance.
WHAT TO DO IF YOU SMELL GAS:
• Immediately call your gas supplier
from a neighbour’s phone. Follow the
gas supplier’s instructions.
• If you cannot reach your gas supplier,
call the fi re department.
Installation and service must be performed by a qualifi ed installer, service
agency or the gas supplier.
Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 4Y8 Canada . (705) 721-1212 .
fax(705)722-6031
Conforms to the standard ANSI Z21.91 2004 Ventless Firebox Enclosures for Unvented Room Heaters
INSTALLATION INSTRUCTIONS FOR THE
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
2 W415-0527 / 09.29.05 PG 3 INTRODUCTION Warranty 4-6 INSTALLATION & FINISHING General Instructions Hood Installation Gas Connector Locations Framing Nailing Tab Instruction Mantle Clearances 7 OPTIONS Optional Blower Installation WARNING • Under no circumstances should this enclosure be modifi ...
3 W415-0527/ 09.29.05 NAPOLEON gas fi replaces are manufactured under the strict Standard of the world recognized ISO 9001:2000 Quality Assurance Certi fi cate. NAPOLEON products are designed with superior components and materials, assembled by trained craftsmen who take great pride in their work. T...
4 W415-0527 / 09.29.05 GENERAL INSTRUCTIONS THE INSTALLATION MUST CONFORM WITH LOCAL CODES OR, IN THE ABSENCE OF LOCAL CODES WITH THE NATIONAL FUEL GAS CODE, ANSI Z223.1 / NFPA 54 AND TO THE NATIONAL ELECTRICAL CODE, ANSI / NFPA 70. Use only accessories designed for and listed with your specifi c fi...