Page 2 - W A R N I N G; •• Under no circumstances should this heater be modified.; TABLE of CONTENTS; PLEASE RETAIN THIS MANUAL FOR FUTURE REFERENCE; INSTALLATION
2 W415-0297 / D / 04.03.03 W A R N I N G •• Under no circumstances should this heater be modified. • P rov i d e a d e q u at e v e n t i l at i o n a n d c o m bu s t i o n a i r. P rov i d e a d e q u at e a c c e s s i b i l i t y cl e a ra n c e f servicing and operating the heater. Never obstru...
Page 4 - In absence of loc; al codes, install the GVF36 to the current; National Fuel Gas Code, ANSI Z223.1 Installation Code; American Nation Standards Institute Inc.; or; National Fire Protection Association Inc.; Batterymarch Park; OXYGEN DEPLETION; and is designed to turn off the heater if; Use only accessories designed for and
4 W415-0297 / D / 04.03.03 THIS GAS FIREPLACE SHOULD BE INSTALLED ANDSERVICED BY A QUALIFIED INSTALLER to conform withlocal codes. Installation practices vary from region to re-gion and it is important to know the specifics that apply toyour area, for example: in Massachusetts State: • The fireplace...
Page 5 - per kW) of the aggregate input rating of all appli-; If the area in which the heater may be oper-; COMBUSTION & VENTILATION; EXAMPLE 1
5 W415-0297 / D / 04.03.03 ROOM 2 ROOM 1 This heater shall not be installed in a confined space orunusually tight construction unless provisions are pro-vided for adequate combustion and ventilation air. In order to avoid the possibility of exposed insulationor vapour barrier coming in contact with ...
Page 6 - FIGURE 2; GAS INSTALLATION; FIGURE 4
6 W415-0297 / D / 04.03.03 1. Move the fireplace into position and secure using the nailing tabs and/or secure to the floor through the ¼"øholes located at either end of the base. 2. Install rigid black pipe, 1/2" type-L copper tubing or, if local codes permit, a 3/8" flex connector and ...
Page 7 - FIGURES 7; FRAMING
7 W415-0297 / D / 04.03.03 NAILING TAB To install the fireplace faceflush with the finished wall,position the framework toa c c o m m o d a t e t h e t h i c k -ness of the finished wall.Bend out the four nailingtabs, attached on either sideof the fireplace and secureto the 2x4 framing. The tabswill...
Page 8 - Hook the hood over the lip of the curtain sup-; HOOD; FINISHING; LOGO PLACEMENT; CATALYTIC DOOR OPENING & CLOSING; DOOR LATCH
8 W415-0297 / D / 04.03.03 The curtain mesh must be kept fully closed during opera-tion to help prevent accidental burns from occurring. The heater must not be used when the hood isremoved. Hook the hood over the lip of the curtain sup- port plate. HOOD CURTAIN MESH FIGURE 11 R e m o v e t h eb a c ...
Page 9 - PHAZER; logs and glowing embers exclusive to Napoleon; LOG PLACEMENT; Fine; logs glow; logs available from your Napo-; CHARCOAL EMBERS; Position the notch located on the end of the center log
9 W415-0297 / D / 04.03.03 PHAZER TM logs and glowing embers exclusive to Napoleon Fireplaces, provide a unique and realistic glowing effectthat is different in every installation. Take the time to care-fully position the glowing embers for a maximum glowingeffect.Log colours may vary. During the in...
Page 10 - Position the hinge screen into place; L36 LOUVRE INSTALLATION; HINGE SCREEN; GVFL LOUVRE INSTALLATION; LOWER LOUVRES
10 W415-0297 / D / 04.03.03 UPPER LOUVRES: In- s e r t t h e u p p e r l o u v r e si n t o t h e s l o t s o n b o t hbrackets. Press the topflange of the hood intot h e f o u r c l i p s l o c a t e dalong the top of the unitas shown. LOWER LOUVRES: At- tach each hinge to the fire-box with 2 screw...
Page 11 - The heater must not be used when the hood is removed.; OPTIONS; DOOR INSTALLATION; CURTAIN ROD BRACKET
11 W415-0297 / D / 04.03.03 NOTE : ORNAMENTAL INSETS CAN NOT BE USED IN CONJUNCTION WITH THE CATALYTIC DOOR This unique patented catalytic system was designed toprovide unparalleled safety and peace of mind. The top ofthe door contains four catalytic tiles which are designed tofilter out combustion ...
Page 12 - r o u t e a; red; OPTIONAL BLOWER INSTALLATION
12 W415-0297 / D / 04.03.03 Attach the connectors from theb l a c k a n d r e d w i r e s t o t h eblower. Attach and secure the variablespeed switch using the nut pro-vided. Plug the harness cordinto the receptacle. The wire harness provided in this kit is a univer-sal harness. When installed, ensu...
Page 13 - route a grounded 2-wire, 60hz power cable to the; GD65 FAN INSTALLATION
13 W415-0297 / D / 04.03.03 FIGURE 27 This optional kit is meant to be used only in conjunctionwith the GD65 Fan Kit, which may be ordered from yourWolf Steel /Napoleon dealer. With the thermostatic sensor option, the fan, when turnedon, becomes thermally activated, and will automaticallyrun approxi...
Page 14 - FF; IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLO-; GAS KNOB; OXYGEN DEPLETION SENSOR; OPERATION / MAINTENANCE; FOR YOUR SAFETY READ BEFORE LIGHTING:
14 W415-0297 / D / 04.03.03 P I N O L O T FF O When lighting and re-lighting, the gas knob cannot beturned from pilot to off unless the knob is depressed. 1. STOP! Read the above safety information on this la- bel. 2. Set the thermostat to lowest setting.3. Turn off all electric power to the firepla...
Page 15 - CORRECT PILOT; AIR SHUTTER OPENINGS; TURN OFF THE GAS AND ELECTRICAL POWER; Catalytic output must be checked annually at the; NG; MAINTENANCE; CATALYTIC TILE; CATALYTIC TILE MAINTENANCE
15 W415-0297 / D / 04.03.03 This procedure must be performed by a qualified service person! Inspect the pilot for any visible contamination or debris(usually lint, pet hair, spider webs, carpet fibre, etc.) andremove. Disconnect the pilot from the pilot tubing line. Using a 7 / 16 ” wrench, remove t...
Page 16 - REPLACEMENTS; REPLACEMENT PARTS
16 W415-0297 / D / 04.03.03 Contact your dealer or the factory for questions concerningprices and policies on replacement parts. Normally all partscan be ordered through your Napoleon dealer or distribu-tor. When ordering replacement parts always give the follow-ing information: 1. M ODEL & S ER...
Page 18 - TROUBLE SHOOTING GUIDE; SYMPTOM
18 W415-0297 / D / 04.03.03 Main burner goesout; pilot stays on. P i l o t f l a m e i s n o t l a r g eenough or not engulfing thethermopile - service or replace Oxygen Depletion Sensor System - correct piping and/or regulator to provide correct pressure Thermopile shorting - clean thermopile conne...
Page 20 - This fireplace must be serviced annually depending on usage.
20 W415-0297 / D / 04.03.03 W olf Steel Fir e p lace Ser vice Histor y This fireplace must be serviced annually depending on usage. Date Service T echnician Name Service Performed Special Concerns Dealer Name