Napoleon GDI-44P - Manual

Napoleon GDI-44P

Napoleon GDI-44P – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
Page: / 16

Table of Contents:

  • Page 2 – TABLE of CONTENTS; PLEASE RETAIN THIS MANUAL FOR FUTURE REFERENCE
  • Page 4 – Operating Instructions; in; GENERAL INSTRUCTIONS
  • Page 5 – Provide adequate ventilation air.; Ensure that existing chimney cleanouts fit properly.; SIDED BACKER PLATE - FRONT VIEW; INSTALLATION
  • Page 6 – See figure 1c; FIGURE 5; It is not practical to level the insert once it has; FIGURE 4; INSERT VENT CONNECTION; FIGURE 2
  • Page 7 – WIRE SIZE; T h e r e i s; GDIBP4; If installing the; FIGURE 7; FINISHING; ALUMINIUM EXTRUSION TRIM KIT; GAS INSTALLATION; WALL SWITCH / THERMOSTAT; FIGURE 8
  • Page 8 – MANTLE WIDTH; Skewering log#2 onto the locating pin may be necessary.; PHAZER; GLOWING EMBERS; LOWER DOOR BRACKETS; LOG PLACEMENT
  • Page 9 – PURGE THE GAS LINE WITH THE GLASS DOOR OPEN.; OPERATION / MAINTENANCE; OPERATING INSTRUCTIONS; WHAT TO DO IF YOU SMELL GAS:; MAINTENANCE
  • Page 10 – For thermodisc replacement:; REPLACEMENT BLOWER INSTALLATION; MAINTENANCE CONTINUED
  • Page 11 – ADJUSTMENTS; PILOT BURNER ADJUSTMENT; FRONT; AIR SHUTTER SETTING; AIR SHUTTER SETTING
  • Page 12 – DESCRIPTION; REPLACEMENTS; REPLACEMENT PARTS
  • Page 13 – a fast acting thermocouple supplied by Wolf Steel Ltd.
  • Page 14 – TROUBLE SHOOTING GUIDE; SYMPTOM
  • Page 16 – This fireplace must be serviced annually depending on usage.
Loading the manual

1

W415-0314 / C / 01.15.04

INSTALLER: THESE INSTRUCTIONS MUST BE CONVEYED TO AND REMAIN WITH THE HOMEOWNER.

Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 4Y8 Canada • (705)721-1212 • fax(705)722-6031

www.napoleonfireplaces.com • [email protected]

GAS-FIRED DIRECT VENT INSERT

INSTALLATION AND OPERATION INSTRUCTIONS FOR:

VENTED GAS FIREPLACE

NATURAL GAS MODELS

GDI-44N

PROPANE GAS MODELS

GDI-44P

CERTIFIED UNDER CANADIAN AND AMERICAN NATIONAL STANDARDS, CSA 2.33, ANSI Z21.88 FOR VENTED GAS FIREPLACE HEATERS

R-2000

WARNING: If the information in these instructions is not followed exactly, a fire

or explosion may result causing property damage, personal injury or death.

FOR YOUR SAFETY

Do not store or use gasoline or other flammable vapours and liquids in the

vicinity of this or any other appliance.

WHAT TO DO IF YOU SMELL GAS:

• Do not try to light any appliance.
• Do not touch any electrical switch.
• Do not use any phone in your

building.

Installation and service must be performed by a qualified installer, service

agency or the gas supplier.

• Immediately call your gas supplier

from a neighbour's phone. Follow the
gas supplier's instructions.

• If you cannot reach your gas supplier,

call the fire department.

CERTIFIED FOR CANADA AND UNITED STATES USING ANSI / CSA METHODS

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - TABLE of CONTENTS; PLEASE RETAIN THIS MANUAL FOR FUTURE REFERENCE

2 W415-0314 / C / 01.15.04 WARNING • The fireplace insert is a vented gas-fired heater. Do not burn wood or other materials in this fireplace insert. • Adults and especially children should be alerted to the hazards of high surface temperatures and should stay away to avoid burns or clothing ignitio...

Page 4 - Operating Instructions; in; GENERAL INSTRUCTIONS

4 W415-0314 / C / 01.15.04 FOR YOUR SATISFACTION, THIS FIREPLACE INSERTHAS BEEN TEST-FIRED TO ASSURE ITS OPERATIONAND QUALITY! Minimum inlet gas supply pressure is 4.5 inches watercolumn for natural gas and 11 inches water column forpropane. Maximum inlet gas pressure is 7 inches watercolumn for nat...

Page 5 - Provide adequate ventilation air.; Ensure that existing chimney cleanouts fit properly.; SIDED BACKER PLATE - FRONT VIEW; INSTALLATION

5 W415-0314 / C / 01.15.04 Provide adequate ventilation air. Provide adequate accessibility clearance forser vicing and operating the fireplace inser t. Never obstruct the front opening of the fire-place inser t. Objects placed in front of the fireplace mustbe kept a minimum of 48" away from the...