Page 2 - TABLE of CONTENTS; PLEASE RETAIN THIS MANUAL FOR FUTURE REFERENCE
2 W415-0223 / D / 01.12.04 Pg 2-4 INTRODUCTION WarrantyGeneral InstructionsGeneral InformationCare of Glass & Plated Parts 5-7 INSTALLATION Insert Vent ConnectionChimney ConnectionWall Switch / ThermostatGas Pipe Installation 7-8 FINISHING Trim Extrusion InstallationLog PlacementDoor Installatio...
Page 4 - GENERAL INSTRUCTIONS
4 W415-0223 / D / 01.12.04 FOR YOUR SATISFACTION, THIS FIREPLACE INSERTHAS BEEN TEST-FIRED TO ASSURE ITS OPERATIONAND QUALITY!Minimum inlet gas supply pressure is 4.5 inches watercolumn for natural gas and 11 inches water column forpropane. Maximum inlet gas pressure is 7 inches watercolumn for natu...
Page 5 - Provide adequate ventilation air.; SIDED BACKER PLATE - FRONT VIEW; INSTALLATION
5 W415-0223 / D / 01.12.04 Provide adequate ventilation air. Provide adequate accessibility clearance forser vicing and operating the fireplace inser t. Never obstruct the front opening of the fire-place inser t. Objects placed in front of the fireplace mustbe kept a minimum of 48" away from the...
Page 6 - FIGURE 3; INSERT VENT CONNECTION; FIGURE 4; FIGURE 2
6 W415-0223 / D / 01.12.04 Move the insert close to its final position inside the wood-burning fireplace. This unit is equipped with 6 levellingscrews located as follows: two are on either side of thecirculation blower on the rear panel; four are located frontand back on either side beneath the log ...
Page 7 - FIGURE 6; FIGURE 7; WALL SWITCH / THERMOSTAT; FINISHING; ALUMINIUM EXTRUSION TRIM KIT
7 W415-0223 / D / 01.12.04 To adjust the trim: If the mitre is out of alignment, openeach side and loosen the two screws at either side trimhinge. Slide the trim up or down to adjust and re-tightenscrews. There is also a very slight in/out adjustment that can be made. Note: Since the side panels ope...
Page 8 - MANTLE WIDTH; LOWER DOOR BRACKET; LOG PLACEMENT
8 W415-0223 / D / 01.12.04 Positioning the logs improperly will cause flame im-pingement and carboning. PHAZER TM logs and glowing embers, exclusive to Napoleon Fireplaces, glow when exposed to direct flame and providea unique and realistic glowing effect that is different in everyinstallation. Take...
Page 9 - OPERATION / MAINTENANCE; OPERATING INSTRUCTIONS; MAINTENANCE
9 W415-0223 / D / 01.12.04 The on-off switch is located behind the left side controldoor. Purge all gas lines with the glass door open. Assurethat a continuous gas flow is at the burner before clos-ing the door. Allow several minutes (5-15) for the flameto stabilize after ignition. Do not operate th...
Page 10 - OPTIONAL BLOWER INSTALLATION
10 W415-0223 / D / 01.12.04 1. Turn off the electrical power and the gas supply to thefireplace insert.2. Remove the fire viewing door. Remove the logs. 3. Detach the two screws from the back of the firebox andremove the panel, as illustrated. 4. Remove the blower access door held on with the re-mai...
Page 11 - ADJUSTMENTS; PILOT BURNER ADJUSTMENT; AIR SHUTTER SETTING; AIR SHUTTER SETTING
11 W415-0223 / D / 01.12.04 Remove the pilot screw cap. Adjust the pilot screw to pro-vide properly sized flame. Turn in a clockwise direction toreduce the gas flow. Replace the pilot screw cap. FIGURE 27 A i r s h u t t e r a d j u s t m e n tm u s t o n l y b e d o n e b y aqualified gas installer...
Page 12 - REPLACEMENTS; REPLACEMENT PARTS
12 W415-0223 / D / 01.12.04 31* W690-0001 MILLIVOLT THERMOSTAT 32* W660-0010 REMOTE CONTROL - ADVANTAGE 32* W660-0011 REMOTE CONTROL - ADVANTAGE PLUS 33* GD660 REMOTE WALL SWITCH C / W 20FT WIRE 34 GI-790KT DECORATIVE BRICK PANELS 35* W175-0162 CONVERSION KIT - NG - LP 35* W175-0192 CONVERSION KIT -...
Page 14 - TROUBLE SHOOTING GUIDE; SYMPTOM
14 W415-0223 / D / 01.12.04 Main burner goes out;pilot stays on. Pilot flame is not large enoughor not engulfing the thermopile. Thermopile shorting Remote wall switch wire is toolong, too much resistance inthe system Faulty thermostat or switch - turn up pilot flame.- replace pilot assembly. - clea...