Page 3 - WARNING; TABLE of CONTENTS; PLEASE RETAIN THIS MANUAL FOR FUTURE REFERENCE; What to do if you smell gas
3 W415-0496 / B / 08.10.05 WARNING • The stove is a vented gas-fired heater. Do not burn wood or other materials in this stove.• Adults and especially children should be alerted to the hazards of high surface temperatures and should stay away to avoid burns or clothing ignition. Keep young children ...
Page 5 - GENERAL INSTRUCTIONS
5 W415-0496 / B / 08.10.05 Expansion / contraction noises during heating up and cool-ing down cycles are normal and to be expected.This appliance is only for use with the type of gas indicatedon the rating plate . This appliance is not convertible for use with other gases, unless a certified kit is ...
Page 6 - Provide adequate accessibility clearance for servicing; LOCATION & CLEARANCES; PILOT INDICATOR
6 W415-0496 / B / 08.10.05 MAINTAIN THESE MINIMUM CLEARANCES TOCOMBUSTIBLES: A. 4" B. 2" * C. 2" STOVE SHOULD NOT BE INSTALLED DIRECTLY ON CARPETING . MINIMUM 48" FROM STOVE TOP TO CEILING TO CEILING FROM STOVE TOP .......................................48" HORIZONTAL VENT SIDES ...
Page 7 - BLOWER INSTALLATION; This unit comes equiped with a pilot indicator
7 W415-0496 / B / 08.10.05 BLOWER INSTALLATION Blower ( SEE LOCATION AND CLEARANCES ) 1. Cut and remove the tie securing the blower switch wires to the heat shield. 2. Connect the white wire coming from below the unit to the terminal on the blower. 3. Connect the black blower wire to the black wire ...
Page 8 - AIR TERMINAL INSTALLATIONS; CANADIAN
8 W415-0496 / B / 08.10.05 AIR TERMINAL INSTALLATIONS ***** R e c o m m e n d e d t o p r e v e n t c o n d e n s a t i o n o n w i n d o w s a n d t h e r m a l b r e a k a g e * * * * * * * * * * It is recommended to use a heat shield and to maximize the distance to vinyl clad sof f its. * * * * *...
Page 9 - VENTING; AIR TERMINAL LOCATIONS
9 W415-0496 / B / 08.10.05 Use only Wolf Steel, Simpson Dura-Vent, Selkirk DirectTemp or American Metal Amerivent venting components.For Simpson Dura-Vent, Selkirk Direct Temp and AmericanMetal Amerivent, follow the installation procedure providedwith the venting components.All outer pipe joints of ...
Page 10 - TYPICAL VENT INSTALLATIONS; PERISCOPE TERMINATION
10 W415-0496 / B / 08.10.05 Use the GD201 periscope kit to locate the air terminationabove grade. The periscope must be installed so that whenfinal grading is completed, the bottom air slot is located aminimum of 12 inches above grade. The maximum allow-able vent length depends on the fireplace, as ...
Page 11 - HORIZONTAL TERMINATION
11 W415-0496 / B / 08.10.05 ELBOW VENT LENGTH VALUES DEFINITIONS HORIZONTAL TERMINATION REQUIREDV E R T I C A LRISE IN FEET(V T ) CALCULATED HORIZONTAL VENT RUNPLUS OFFSETS IN FEET (H T ) FIGURE 5 45º FIGURE 6 90° H 1 H 2 when (H T ) < (V T ) for the following symbols used in the venting calcula-...
Page 13 - VERTICAL TERMINATION
13 W415-0496 / B / 08.10.05 VERTICAL TERMINATION Example 3: V 1 = 5 ft V 2 = 10 ft V T = V 1 + V 2 = 5 + 10 = 15 ft H 1 = 3 ft H 2 = 2.5 ft H R = H 1 + H 2 = 3 + 2.5 = 5.5 ft H O = .03(one 45º elbow + three 90º elbows - 135º)= .03(45+90+90+90-135)=5.4 H T = H R + H O = 5.5 + 5.4 = 10.9 ft H T + V T ...
Page 15 - WALL AND CEILING PROTECTION
15 W415-0496 / B / 08.10.05 This application occurs when venting through an exteriorwall. Having determined the air terminal location, cut andframe a hole in an exterior wall with a minimum rectangleopening of 10" x 9". IMPORTANT: FOR OPTIMUM PERFORMANCE, THE STOVE PIPESHOULD RISE ¼" PER...
Page 16 - VERTICAL VENTING INSTALLATION; HORIZONTAL VENTING INSTALLATION
16 W415-0496 / B / 08.10.05 4. If more than one length of liner needs to be used to reach the stove, couple them together as illustrated in FIGURE 24 . Seal the joints using the same procedure as described above.The vent system must be supported approximately every10 feet along a horizontal run. Use...
Page 17 - STOVE VENT CONNECTION; GAS INSTALLATION; RESTRICTING VERTICAL VENTS
17 W415-0496 / B / 08.10.05 1. Attach the adjustable pipe to the last section of rigid piping. Secure with screwsand seal. 2. Install the 4" aluminium flex- ible liner to the stove. Securewith 3 screws and flat wash-ers. Seal the joint and screwholes using high tempera-ture sealant. 3. Run a bea...
Page 18 - FINISHING; GLASS DOOR INSTALLATION
18 W415-0496 / B / 08.10.05 1. Lift the top cast piece off of the unit. 2. Detach the front cast piece from the side pieces by removing the screws from the brackets located in the upperinside corners. 3. Slide the front straight up to remove. FINISHING GLASS DOOR INSTALLATION AND REMOVAL CAST FRONT ...
Page 19 - LOG LOCATING SCREWS
19 W415-0496 / B / 08.10.05 LOG PLACEMENT LOGO PLACEMENT Remove the backing from the the logo and position ontothe control door as shown. It is not necessary to remove the cast front, however,this will make for a more simple log installation. In order to assemble the log set, the door must be remove...
Page 20 - OPERATION / MAINTENANCE; OPERATING INSTRUCTIONS
20 W415-0496 / B / 08.10.05 Purge all gas lines with the glass door removed. Assurethat a continuous gas flow is at the burner before closingthe door. The on-off switch is located on the back of the unit at thetop right corner on model GDS20. When lit for the first time, the fireplace will emit a sl...
Page 21 - ADJUSTMENTS; PILOT BURNER ADJUSTMENT
21 W415-0496 / B / 08.10.05 Adjust the pilot screw to provide properly sized flame. Turnin a clockwise direction to reduce the gas flow. FIGURE 34 FIGURE 35 Air shutter adjustment must only be done by a qualified gas installer! FIGURE 36 ADJUSTMENTS PILOT BURNER ADJUSTMENT VENTURI ADJUSTMENT TURN OF...
Page 22 - REPLACEMENTS; REPLACEMENT PARTS
22 W415-0496 / B / 08.10.05 Contact your dealer for questions concerning prices andavailability of replacement parts. Normally all parts canbe ordered through your Napoleon dealer or distributor.When ordering replacement parts always give the fol-lowing information: 1. M ODEL & S ERIAL N UMBER O...
Page 24 - TROUBLE SHOOTING GUIDE; SYMPTOM
24 W415-0496 / B / 08.10.05 Pilot will not light. - check if pilot can be lit by a match- check that the wire is connected to the push button ignitor.- check if the push button ignitor needs tightening.- replace the wire if the wire insulation is broken or frayed.- replace the electrode if the ceram...
Page 26 - This fireplace must be serviced annually depending on usage.
26 W415-0496 / B / 08.10.05 W olf Steel Fir eplace Ser vice Histor y This fireplace must be serviced annually depending on usage. Date Service T e chnician Name Service Performed Special Concerns Dealer Name