Milwaukee LSM40MP-2 - Manual

Milwaukee LSM40MP-2

Milwaukee LSM40MP-2 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
29 Page 29
30 Page 30
31 Page 31
32 Page 32
Page: / 32

Table of Contents:

  • Page 2 – TABLE OF CONTENTS; Please read and understand these; stone; INTRODUCTION; WARNING; GENERAL INFORMATION
  • Page 3 – Table 1
  • Page 4 – Flame appearance will diminish 4% per; Table 4; Figure 1; Table 2; REQUIREMENTS FOR THE COMMON-; Figure 2
  • Page 5 – LOCATION; Figure 3; Figure 3 - Typical Installation; COLD CLIMATE INSULATION; Cross Corner
  • Page 6 – Figure 6 - Side Elevation View; Termination Heights For Vents; Vertical Vent Termination Clearances; These instructions should be used as a; Vertical Vent Termination Clearances; Figure 4; Horizontal Vent Termination Clearances; Figure 6; Minimum; Figure 4 - Multiple Terminations
  • Page 7 – ExTERIOR HORIZONTAL VENT TERMINATION CLEARANCE REQUIREMENTS; Minimum Clearances; condensation; Figure 7; NOTE: Local Codes Or Regulations May Require
  • Page 8 – Shelf Height; Figure 8; MINIMUM CLEARANCES TO COMBUSTIBLES; When the; Figure 9; Top Vent - with 2 Feet Vertical Vent and One 90 Degree Elbow
  • Page 9 – Figure; DO NOT; DETAILED INSTALLATION STEPS; Page 9
  • Page 10 – Fireplace Dimensions; FIREPLACE AND FRAMING SPECIFICATIONS; Framing Dimensions
  • Page 11 – Back wall of chase/enclosure; Schedule 40 Pipe; Table 6; Proper Sizing of Gas Line; Right Side; Step 2. ROUTING GAS LINE
  • Page 12 – VENT RESTRICTOR INSTALLATION; Step 3. INSTALL THE VENT SYSTEM; See Approved Vent Components on; These fireplaces must be vented directly; Note: The restrictor is included within the
  • Page 13 – Figure 17 and Figures 25 through 27 on; Secure VentTM; Figure 5 on Page 6; Effective Vent Length; Model; Table 7
  • Page 15 – Figure 22 - Roof Framing; on; Swivel Joint; Storm
  • Page 16 – Table B; Ceiling; Table A; Maximum; VERTICAL VENT FIGURES/TABLES; • Secure VentTM (rigid vent pipe) is shown; A Vent Restrictor, as shown in Figure 15 on Page
  • Page 17 – TYPICAL HORIZONTAL VENT INSTALLATION; Support the vertical portion of the venting system; to
  • Page 18 – For wall thicknesses greater than; Venting Connection and Exterior Wall Recessing; See Figure 12 on Page 10 for Minimum; Distance to Base of Appliance; Step B; IMPORTANT: The vent termination is hot
  • Page 19 – Table 8; range of exterior wall thicknesses.; zontal vent run is needed, then; HORIZONTAL VENT FIGURES/TABLES; • Secure VentTM
  • Page 21 – CAUTION; Figures 35 and; the current CSA C22-1 Canadian; Verify proper operation after servicing.; ELECTRONIC; See Figure 36 for detailed; drawing of junction box /; see Figure 12 on Page
  • Page 22 – Gas; WIRING
  • Page 23 – Never use an open flame to; Millivolt Appliance Checkout
  • Page 24 – Excessive use of embers may result in sooting or poor flame.; Place logs 2 and 3; Mixture Of Volcanic Stone And Vermiculite
  • Page 27 – adjust the flame height as desired, by sliding; Main Burner Factory Air Shutter; Burner Air Shutter Adjustment Procedure
  • Page 28 – FINISHING REQUIREMENTS; door track and the surface of the finish material.
  • Page 29 – LENNOx HEARTH PRODUCTS; La chimenea caliente; Un foyer chaud peut causer; ADVERTENCIA; ATTACHING SAFETY IN OPERATION WARNINGS; Hot Fireplace Will Cause; LENNOx HEARTH PRODUCTS; AVERTISSEMENT
  • Page 31 – this installation assumes responsibility for this conversion.; assume les responsabilités liées à la conversion.; Burner Assembly
  • Page 32 – VERIFY THE PROPER ORIFICE SIZE BE-; Millivolt & Electronic Gas Valves; Millivolt & Electronic Pilot Assemblies; Table 9
Loading the manual

DR

AF

T

3/0

8/2

01

0

INSTALLER: Leave this manual with the appliance.

CONSUMER: Retain this manual for future reference.

INSTALLATEUR: Laissez cette notice avec l'appareil.

CONSOMMATEUR: Conservez cette notice pour consul-

tation ultérieure.

- Do not store or use gasoline or other flammable vapors and

liquids in the vicinity of this or any other appliance.

- WHAT TO DO IF YOU SMELL GAS

• Do not try to light any appliance.

• Do not touch any electrical switch; do not use any

phone in your building.

• Immediately call your gas supplier from a neighbor’s

phone. Follow the gas supplier’s instructions.

• If you cannot reach your gas supplier, call the fire

department.

- Installation and service must be performed by a quali-

fied installer, service agency or the gas supplier.

WARNING: If the information in these instructions is

not followed exactly, a fire or explosion may result

causing property damage, personal injury or death.

- Ne pas entreposer ni utilizer d’essence ni d’autres

vapeurs ou liquides inflammables dans le voisinage

de cet appareil ou de tout autre appareil.

- QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ:

• Ne pas tenter d’allumer d’appareil.

• Ne touchez à aucan interrupteur. Ne pas vous servir

des téléphones se trouvant dans le bâtiment où vous

trouvez.

• Appelez immédiatement votre fournisseur de gaz

depuis un voisin. Suivez les instructions du fournis-

seur.

• Si vous ne pouvez rejoindre le fournisseur de gaz,

appelez le service des incindies.

- L’installation et l’entretien doivent être assurés par un

installateur ou un service d’entretien qualifié ou par

le fournisseur de gaz.

AVERTISSEMENT: Assurez-vous de bien suivre les

instructions données dans cette notice pour réduire

au minimum le risque d’incindie ou d’explosion ou

pour éviter tout dommage matériel, toute blessure

ou la mort.

INSTALLATION INSTRUCTIONS

Ce manuel d’installation est disponible en francais, s implement en faire
la demande. Numéro de la pièce 850,026CF.

MODELS

OTL Report No. 116-F-22-5

US

Portland

P/N 850,026M REV. E 03/2010

Direct

-

Vent

MONTEBELLO™

This appliance may be installed in an aftermarket permanently located, manufactured home (USA only) or mobile

home, where not prohibited by local codes. This appliance is only for use with the type of gas indicated on the rating

plate. This appliance is not convertible for use with other gases, unless a certified kit is used.

WARNING AVERTISSEMENT

UNE SURFACE VITR E CHAUDE PEUT

CAUSER DES BR LURES.

LAISSER REFROIDIR LA SURFACE

VITRE AVANT D'Y TOUCHER.

NE PERMETTEZ JAMAIS UN ENFANT

DE TOUCHER LA SURFACE VITRE.

HOT GLASS WILL

CAUSE BURNS.

DO NOT TOUCH GLASS

UNTIL COOLED.

NEVER ALLOW CHILDREN TO

TOUCH GLASS.

TM

Millivolt Models

Electronic Models

LSM40MN-2

LSM40EN-2

LSM40MP-2

LSM45EN-2

LSM45MN-2

LSM45MP-2

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Other Manuals for Milwaukee LSM40MP-2

Summary

Page 2 - TABLE OF CONTENTS; Please read and understand these; stone; INTRODUCTION; WARNING; GENERAL INFORMATION

2 TABLE OF CONTENTS Packaging..........................................Page. 2Introduction.......................................Page. 2General.Information...........................Page. 2Massachusetts.and.New.York....Requirements.................................Page. 4Cold.Climate.Insulation.........

Page 3 - Table 1

3 Note: Installation and repair should be done by a qualified service person. The appliance should be inspected before use and at least annually by a professional service person. More frequent cleaning may be required due to excessive lint from carpeting, bed- ding material, etcetera. It is imperati...

Page 4 - Flame appearance will diminish 4% per; Table 4; Figure 1; Table 2; REQUIREMENTS FOR THE COMMON-; Figure 2

4 NOTE:.DIAGRAMS.&.ILLUSTRATIONS.ARE.NOT.TO.SCALE. These.appliances.must.be.isolated.from.the. gas.supply.piping.system.(by.closing.their. individual.manual.shut-off.valve).during.any. pressure. testing. of. the. gas. supply. piping. system. at. test. pressures. equal. to. or. less than .1/2.psi...

Other Milwaukee Models