Honeywell XL 800 SERIES- User Manual

Honeywell XL 800 SERIES

Honeywell XL 800 SERIES– User Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
29 Page 29
30 Page 30
31 Page 31
32 Page 32
33 Page 33
34 Page 34
35 Page 35
36 Page 36
Page: / 36

Table of Contents:

  • Page 3 – WARNING; General; Installation
  • Page 4 – Wiring
  • Page 5 – XL800 Series Power Consumption
  • Page 6 – CONTROLLER MODULE; LonWorks or Panel Bus
  • Page 7 – Description of the XCL8010AU; Overview; PC or HMI
  • Page 10 – Interfaces and Bus Connections; Technical Data; System Data; Smoke Control Configuration
  • Page 11 – Panel Reset; CAUTION; Typical Power Limited Circuit for XL800
  • Page 12 – How to Connect Panel Bus and L; Bus Mixed Controller Systems; Connecting I/O Modules
  • Page 13 – Setting Address of Panel Bus I/O Modules
  • Page 14 – Setting the I/O Bus Switch; Bus Topologies; Mounting/Dismounting Modules
  • Page 15 – Mounting Sockets; Connecting Sockets
  • Page 16 – Dismounting Sockets; Mounting/Dismounting Electronic Modules; Mounting Electronic Modules
  • Page 17 – Dismounting Electronic Modules; Connecting via C-Bus; Connecting to the Controller; Setting the C-Bus Termination Switch; Shielding; Connecting HMIs or Laptops; Connecting the XI582 Operator Interface
  • Page 18 – Features; Interface and Terminals; Service LED and Button
  • Page 19 – HMI Interface
  • Page 21 – Description of the I/O Modules; Common Features
  • Page 22 – Analog Input Modules; Types of Analog Input Modules
  • Page 23 – XFL821AU Connection Examples
  • Page 24 – Analog Output Modules; Types of Analog Output Modules
  • Page 25 – Modules with Manual Overrides; XFL822AU Connection Example
  • Page 26 – Binary Input Modules; Types of Binary Input Modules
  • Page 27 – Status LEDs
  • Page 28 – Relay Output Modules; Types of Relay Output Modules
  • Page 29 – Permissible Loads
  • Page 30 – Connection Examples; POWER MODULE
  • Page 31 – Troubleshooting; Testing Wiring Connections
  • Page 32 – Service LED
  • Page 33 – C-Bus Tx and Rx LEDs
  • Page 34 – I/O Modules Troubleshooting; Power LED of I/O Modules
  • Page 35 – Service LED of I/O Modules
Loading the manual

Copyright © 2008 Honeywell GmbH

All Rights Reserved

EN1B-0410GE51 R0908A

XL 800 Series

FOR SMOKE CONTROL


HONEYWELL EXCEL 5000 OPEN SYSTEM

INSTALLATION AND COMMISSIONING INSTRUCTIONS

CONTENTS

General ............................................................................... 3

Before Installation ............................................................. 3

Installation ......................................................................... 3

Wiring ................................................................................. 4

XL800 Series Power Consumption ................................ 5

I/O Modules ................................................................... 5

Description of the XCL8010AU

Controller Module ......... 7

Overview........................................................................ 7

Interfaces and Bus Connections .................................. 10

Technical Data ............................................................. 10

System Data........................................................... 10

Operational Environment ....................................... 10

Smoke Control Configuration ....................................... 10

Data File Set-Up .......................................................... 11

Panel Reset ................................................................. 11

Typical Power Limited Circuit for XL800 ...................... 11

Connecting Single Bus Controller Systems ................. 11

XCL8010AU, I/O Modules on Single Rail ............... 12

Multiple Rails in Single Cabinet .............................. 12

LonWorks Bus I/O Modules in Separate Rooms .... 12

How to Connect Panel Bus and L

ON

W

ORKS

Bus Mixed

Controller Systems ...................................................... 12

Connecting I/O Modules......................................... 12

Connecting I/O Modules to the XCL8010AU .......... 12

Setting Address of Panel Bus I/O Modules .................. 13

Setting the I/O Bus Switch ........................................... 14

L

ON

W

ORKS

Bus Topologies.......................................... 14

C-Bus Topologies ........................................................ 14

Mounting/Dismounting Modules .................................... 14

Mounting/Dismounting Controller/Sockets ................... 15

Mounting Sockets................................................... 15

Connecting Sockets ............................................... 15

Dismounting Sockets ............................................. 16

Mounting/Dismounting Electronic Modules .................. 16

Mounting Electronic Modules ................................. 16

Dismounting Electronic Modules ............................ 17

Connecting via C-Bus .................................................. 17

Connecting to the Controller................................... 17

Setting the C-Bus Termination Switch.................... 17

Shielding ................................................................ 17

Connecting HMIs or Laptops ........................................ 17

Connecting the XI582 Operator Interface ............... 17

Connecting Laptops (XL-Online/CARE) ................. 18

XCL8010AU Terminals ........................................... 18

Features ....................................................................... 18

L

ON

W

ORKS

Interface and Terminals ....................... 18

L

ON

W

ORKS

Service LED and Button ....................... 18

C-Bus Tx LED and Rx LED .................................... 19

Reset Button ........................................................... 19

HMI Interface .......................................................... 19

Alarm and Power LEDs .......................................... 20

Watchdog Status .................................................... 20

Modem Interface..................................................... 20

I/O Bus Switch S2................................................... 20

C-Bus Termination Switch S1 ................................. 21

Memory .................................................................. 21

Description of the I/O Modules ....................................... 21

Common Features ....................................................... 21

Analog Input Modules .................................................. 22

Types of Analog Input Modules .............................. 22

Features ................................................................. 22

Terminals................................................................ 22

XFL821AU Connection Examples .......................... 23

Analog Output Modules................................................ 24

Types of Analog Output Modules ........................... 24

Features ................................................................. 24

Terminals................................................................ 24

Technical Data........................................................ 24

Modules with Manual Overrides ............................. 25

XFL822AU Connection Example ............................ 25

Synchronization Behavior of Analog Output Module
Configured as Floating Output................................ 25

Binary Input Modules ................................................... 26

Types of Binary Input Modules ............................... 26

Features ................................................................. 26

Terminals................................................................ 26

Technical Data........................................................ 26

Status LEDs............................................................ 27

XF823AU Connection Examples ............................ 27

Relay Output Modules.................................................. 28

Types of Relay Output Modules ............................. 28

Features ................................................................. 28

Terminals................................................................ 28

Permissible Loads .................................................. 29

Status LEDs with Manual Overrides ....................... 29

Connection Examples............................................. 30

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Other Manuals for Honeywell XL 800 SERIES

Summary

Page 3 - WARNING; General; Installation

Excel 800 3 EN1B-0410GE51 R0908A WARNING This equipment generates, uses, and can radiate radio frequency energy, and if not installed and used in accordance with the instructions manual, may cause interference to radio communications. It has been tested and found to comply with the limits for a Clas...

Page 4 - Wiring

Wiring Excel 800 EN1B-0410GE51 R0908A 4 Wiring All wiring to the XL800 controller is unsupervised, except as noted. All circuits are power limited, except for AC power circuits, relay contacts and other circuits as noted. All field wiring terminals accept 24 AWG to 14 AWG (0.25 mm 2 to 2 mm 2 ) cond...

Page 5 - XL800 Series Power Consumption

Excel 800 Wiring 5 EN1B-0410GE51 R0908A XL800 Series Power Consumption When selecting the appropriate power supply, the power consumption of the XL800 modules must be taken into account. Table 3. XL800 power consumption max. power consumption model 24 Vac, 60 Hz 24 Vdc XCL8010AU with watchdog load 6...

Other Honeywell Models