V-Plex® Series Motion Sensors

DT8050A-SN

V-Plex

®

DUAL TEC

®

Motion Sensor with Anti-Mask - Installation Instructions

1

SELECT THE MOUNTING LOCATION

6' 9" - 8' 9"

(2.1 - 2.7 m)

12”

(30 cm)

7' 6"

(2.3 m)

*

*



2

3

1

2

DT8050A-SN_step2-ii

OPEN THE SENSOR

Mounting location guidelines:

• The optimal range is obtained at a mounting height

of 7’ 6” (2.3m).

• Allow a clear line-of-sight to all areas to protect.
• Avoid mounting anything within 12” (30cm) in front of the sensor*.
• Do not directly face windows.
• Avoid close proximity to moving machinery, fluorescent lights, and heating/cooling sources.
• Not for use in applications with pets.

1. Turn the arrow to point to the Unlock symbol.
2. Press firmly on housing latch.
3. Gently separate the front and rear housing.

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Other Manuals for Honeywell DT8050A

Summary

Page 2 - MOUNT THE SENSOR; Down; Look; LED; Enabled; MW; MAX; MIN; WIRE THE SENSOR; Polling Loop; • The rear tamper plate

- 2 - #6 (3.5 mm) A A B B B A B #6 x 1 1/4" (3.5 mm x 32 mm) X X A B B B DT8050A-SN_step3-ii 3 MOUNT THE SENSOR *Look Down Enabled Look Down Disabled P U L L T O D I S A B L E L O O K D OW N MAX M W S E N S I T I V I T Y ON HIGH TRAFFIC INHIBIT ANTI-MASK L E D OFF ON 1 2 3 1 2 3 D T 8 0 5 0 A-SN...

Page 3 - Walk Test Reset; WALK TEST THE SENSOR AND ADJUST AS NEEDED; DETECTION PATTERNS; Zones; Lower; Note

- 3 - 30 sec 30 0 45 20 10 MW SENSITIVITY MAX MIN Walk Test Reset 1/2 sec.hold 4x < 4’ (1.2m) DT8050A-SN_step6-ii ON 1 2 3 ON OFF 6 WALK TEST THE SENSOR AND ADJUST AS NEEDED 7 DETECTION PATTERNS Top View Side View 0 PLAN VIEW ALL ZONES 7’ 2 m 0 0 13’ 4 m 20’ 6 m 27’ 8 m 33’ 10 m 40’ 12 m 7’ 2 m 1...

Page 5 - APPROVAL LISTINGS; FCC part 15, Class B verified; UL Notes; : All interconnecting devices must be UL Listed. The

- 5 - APPROVAL LISTINGS • FCC part 15, Class B verified • IC ICES-003, Class B verified • UL 639 • ULC S306-03 • SIA-PIR-01 Passive Infrared detector standard features for false alarm immunity. Product must be tested at least once each year. All wiring must be in accordance with: the National Electr...

Other Honeywell Models