Honeywell TRUEUV UV100RM- User Manual

Honeywell TRUEUV UV100RM

Honeywell TRUEUV UV100RM– User Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
Page: / 24

Table of Contents:

  • Page 2 – ORDERING INFORMATION; SAFETY PRECAUTIONS
  • Page 3 – When installing this product...; MERCURY NOTICE; INSTALLATION; Internal Mounting
  • Page 5 – External Mounting
  • Page 6 – WIRING; MAINTENANCE; WARNING
  • Page 7 – TROUBLESHOOTING
  • Page 8 – PARTS LIST
  • Page 9 – NOTICE TECHNIQUE; Système de traitement d'air TrueUV; pour; APPLICATION; VEUILLEZ LIRE CE QUI SUIT AVANT DE METTRE SOUS TENSION; Table des matières
  • Page 10 – POUR COMMANDER; CONSIGNES DE SÉCURITÉ
  • Page 11 – Avant d'installer ce produit...; AVIS SUR LE MERCURE; Montage interne
  • Page 13 – Montage externe
  • Page 14 – Montage du hublot; CÂBLAGE; ENTRETIEN; AVERTISSEMENT
  • Page 15 – DÉPANNAGE
  • Page 16 – PIÈCES
  • Page 17 – INFORMACIÓN DEL PRODUCTO; Sistema de tratamiento de serpentín; APLICACIÓN; LEA ESTO PRIMERO ANTES DE ACTIVAR EL SUMINISTRO ELÉCTRICO; Contenido
  • Page 18 – INFORMACIÓN PARA PEDIDOS; PRECAUCIONES DE SEGURIDAD
  • Page 19 – Al instalar este producto...; NOTIFICACIÓN SOBRE EL MERCURIO; INSTALACIÓN; Montaje interno
  • Page 21 – Montaje externo
  • Page 22 – Montaje de la ventanilla indicadora; CABLEADO; MANTENIMIENTO; ADVERTENCIA
  • Page 23 – LOCALIZACIÓN Y SOLUCIÓN DE PROBLEMAS
  • Page 24 – LISTA DE PARTES
Loading the manual

PRODUCT DATA

68-0297EFS-05

UV100RM TrueUV™ Coil Treatment System

APPLICATION

When installed at the air conditioner coil, TrueUV helps

prevent surface micro-organism contaminants such as mold

from forming on the air conditioning coil and drain pan which

can lower the efficiency of the cooling system and can allow

unwanted odors into the home.

FEATURES

• Remote mount bulb and ballast allow for flexible

installation in any application.

• 24V ballast does not require electrician to install

additional outlets.

• SnapLamp™ replacement bulb allows for easy

maintenance. No screws needed for bulb replacement.

• Ballast can be set to run continuously or to cycle -

extending bulb life.

• Shield allows installer to direct UV-C light away from

access panels for safety and onto A/C coil where the

light is needed.

• TrueUV can be installed on exterior surfaces or on

interior surfaces.

• Adjustable mounting bracket allows TrueUV to be

installed in tight locations.

• Exterior mounting requires little clearance, so TrueUV

can be installed in closets and tight spaces.

• Indicator window allows safe viewing of lamp

operation.

• UV-C light kills airborne bacteria and surface mold.
• TrueUV does not produce ozone.
• Five-year limited warranty.

READ THIS FIRST BEFORE TURNING ON POWER

1.

Snap in lamp, do not twist.

2.

Attach mounting base.

3.

Turn ballast to ON or CYCLE.

4.

Turn power back on.

IMPORTANT

15 VA minimum needs to be available if connecting to

equipment transformer. If available VA is not known then

AT40A1162 transformer can be used.

M27542

1

2

3

Contents

Specifications ...................................................................

2

Ordering Information ........................................................

2

Safety Precautions ...........................................................

2

Installation ........................................................................

3

Wiring ...............................................................................

6

Checkout ..........................................................................

6

Maintenance .....................................................................

6

Troubleshooting ................................................................

7

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - ORDERING INFORMATION; SAFETY PRECAUTIONS

UV100RM TRUEUV™ COIL TREATMENT SYSTEM 68-0297EFS—05 2 ORDERING INFORMATION When purchasing replacement and modernization products from your TRADELINE® wholesaler or distributor, refer to the TRADELINE® Catalog or price sheets for complete ordering number. If you have additional questions, need furth...

Page 3 - When installing this product...; MERCURY NOTICE; INSTALLATION; Internal Mounting

UV100RM TRUEUV™ COIL TREATMENT SYSTEM 3 68-0297EFS—05 When installing this product… 1. Read these instructions carefully. Failure to follow them could damage the product or cause a hazardous condition. 2. Check the rating given in the instructions and on the product to make sure the product is suita...

Page 5 - External Mounting

UV100RM TRUEUV™ COIL TREATMENT SYSTEM 5 68-0297EFS—05 Fig. 7. Apply Safety Precautions/Template sticker to outside of duct. External Mounting Adhere Safety Precautions/Template sticker in chosen location. Drill 1-9/16–inch hole for bulb. Mount base using self- tapping screws. Snap bulb into handle a...

Other Honeywell Models