Table of Contents:

  • Page 2 – COMPATIBILITY
  • Page 3 – WIRING GUIDELINES; Overview
  • Page 4 – Cable Type
  • Page 5 – NETWORK CONFIGURATION; Maximum Number of Devices
  • Page 6 – Maximum Cable Length
  • Page 8 – NETWORK ADAPTER; Network Adapter Status LED; Condition of the Status LED
  • Page 9 – INTEGRATION; Global Commands
  • Page 10 – TB7200 Integration – Graphical User Interface (GUI) objects
  • Page 11 – TB7300 Integration – Graphical User Interface (GUI) Objects
  • Page 12 – Configuration Objects; Integrating Honeywell Devices on an MS/TP Network
  • Page 13 – Graphical interfaces; Free programmed object or loops; Retries and Timeouts
  • Page 14 – TROUBLESHOOTING
  • Page 15 – APPENDIX; Supported BACnet Services
  • Page 16 – BACNET OBJECTS SUPPORTED; Device Objects
  • Page 17 – Objects Table
  • Page 20 – Standard Object Types Supported; List of Proprietary Properties
  • Page 21 – Property Value Range Restrictions
  • Page 22 – Property Enumeration Sets for BV & BI Objects
  • Page 23 – Enumeration Sets for MV Objects
Loading the manual

INTEGRATION MANUAL

Put Bar Code Here

63-4524-01

BACnet Integration Manual for

TB7200 & TB7300 Series

Thermostats

TB7200 Series

Thermostat

TB7300 Series

Thermostat with

Occupancy Sensor

Contents

Product Overview ............................................................. 1

Compatibility ..................................................................... 2

Tips and Things You Need To Know ................................. 2

Wiring Guidelines ............................................................. 3

Network Configuration ...................................................... 5

Network Adapter ............................................................... 8

Integration ........................................................................ 9

Troubleshooting ................................................................ 14

Appendix .......................................................................... 15

BACnet Objects Supported .............................................. 16

PRODUCT OVERVIEW

The TB7200 Series PI thermostats are designed for zoning

applications, and the TB7300 Series PI thermostats are

designed for fan coil control. Both Series are communicating

thermostats with models available in BACnet

®

MS/TP and

ZigBee

®

wireless mesh protocols and can be easily

integrated into a WEBs-AX building automation system based

on the NiagaraAX

®

platform.

TB7200 and TB7300 Series thermostats are compatible with

the Honeywell Occupancy Sensor Cover. Thermostats

equipped with an occupancy sensor cover provide advanced

active occupancy logic, which will automatically switch

occupancy levels from Occupied to Stand-By and Unoccupied

as required by local activity being present or not. This

advanced occupancy functionality provides advantageous

energy savings during occupied hours without sacrificing

occupant comfort. All thermostats can be ordered with or

without a factory installed PIR cover.

More information

The additional following documentation is available on

http://customer.honeywell.com.

• TB7200 Series Installation Instructions (form number 62-

2019).

• TB7300 Series Installation Instructions (form number 62-

2018).

• PIR Application Guide for TB7200 and TB7300 Series

Thermostats (form number 63-4526).

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - COMPATIBILITY

BACNET INTEGRATION MANUAL FOR TB7200 & TB7300 SERIES THERMOSTATS 63-4524—01 2 COMPATIBILITY Honeywell TB7200 and TB7300 Series thermostat compatiblity information is provided in Table 1. Table 1. TB7200 Series and TB7300 Series Thermostat Compatibility Information * 128 total devices supported. ...

Page 3 - WIRING GUIDELINES; Overview

BACNET INTEGRATION MANUAL FOR TB7200 & TB7300 SERIES THERMOSTATS 3 63-4524—01 • To assign a Room Temperature (AV7) value manually, users must first enable the Override mode in the Room Temp Override (BV8) object. • To assign a Room Humidity (AV10) value manually, users must first enable the Over...

Page 4 - Cable Type

BACNET INTEGRATION MANUAL FOR TB7200 & TB7300 SERIES THERMOSTATS 63-4524—01 4 Cable Type Honeywell recommends the use of balanced 22-24 AWG twisted pair with a characteristic impedance of 100-130 ohms, capacitance of 30 pF/ft or lower. A braided shield is also recommended. Impedance A value base...

Other Honeywell Models