Honeywell IQ5IO16DIB - User Manual

Honeywell IQ5IO16DIB

Honeywell IQ5IO16DIB – User Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
Page: / 13

Table of Contents:

  • Page 2 – Physical; FUNCTIONALITY; HARDWARE; Note: All modules shown with terminal covers removed.
  • Page 3 – Function; with a maximum load of 12 A; Input/Output Channels; Cable Screening; or fan speed
  • Page 4 – Data Sheet; Note: The 24VDC OUT terminal can source up to
  • Page 5 – Note: The relay on channel 5 on the 8DO and 8DO/HOA has a; T1L IO Bus
  • Page 6 – wiring; Maximum I/O Bus Length; Note: One or more additional power supplies may be required on; Maximum Number of Modules; This bus supply is derived from the controller’s
  • Page 7 – The 0 V connection must be made when an; I/O Module Addressing; Green indicates normal; Service Button; Note: The language used for display text can changed.; Labelling; XXXXXXXXXXXXXXXXXXXXXX; FIRMWARE; from controller
  • Page 8 – New versions of firmware may be made available from time to
  • Page 10 – ACCESSORIES; RADIO FREQUENCY STATEMENTS AND REQUIREMENTS
  • Page 11 – Le present appareil est conforme aux CNR d’Industrie Canada; SPECIFICATION; ELECTRICAL; Minimum 60 dB series mode rejection
  • Page 12 – Maximum Total Load; CONTROLS; MECHANICAL; Flame Retardant Polycarbonate.; Connectors; ENVIRONMENTAL; This device is suitable for indoor use only.; Approvals and Certifications
  • Page 13 – Trend Control Systems Limited
Loading the manual

D

Data Sheet

IQ5

I/O Module

Description

The IQ

®

5-IO range of I/O modules are designed for

use with the IQ5 controller, to provide input and output channel
connection points.
A comprehensive choice of I/O types is available including
universal inputs/outputs (UIO), digital inputs (DI), digital/relay
outputs (DO). A

‘hand-off -auto’ variant (8DO-HOA) is also

available, off ering manual override of module outputs.
Integral I/O bus connectors allow easy and convenient

‘side-

byside

’ module installation or, by using

wiring

adapters,

modules can be installed up to 300 meters apart.

Features

▪ Universal input/output, digital input, digital output variants
▪ Hand-off -auto option (on 8DO-HOA)
▪ Up to 300 I/O channels per controller (subject to licence)
▪ T1L high-speed secure bus connection to controller
▪ Side-by-side or remote connection options
▪ Up to 300 metres (1000 ft) between cable connected
modules
▪ Powered from controller or external PSU
▪ Two part I/O connectors for easy installation/commissioning
▪ Surface or DIN rail mounting, DIN 19 size 2 standard
enclosur

IQ5-IO I/O Module

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - Physical; FUNCTIONALITY; HARDWARE; Note: All modules shown with terminal covers removed.

D Physical FUNCTIONALITY HARDWARE The range of IQ5-IO Expansion Modules comprises the following variants: 16UIO 16DI 8DO 8DO-HOA 8UIO -105 Note: All modules shown with terminal covers removed.

Page 3 - Function; with a maximum load of 12 A; Input/Output Channels; Cable Screening; or fan speed

3 Enclosure Each IQ5-IO Module is housed in a polycarbonate enclosure compatible with the DIN43880 and DIN 19 size 2 standard and with a complimentary styling to the IQ5 controller. Integral clips on the back of the case enable the unit to be clipped on to (and quickly released from) a standard TS35...

Page 4 - Data Sheet; Note: The 24VDC OUT terminal can source up to

Data Sheet 4 Example wiring Digital input: Used for a volt free contact, logic circuit (e.g. TTL, CMOS), open collector (transistor) or open drain (FET). Example wiring free collector circuit The volt free contact has a nominal wetting current of 3.5 mA . The input is ON when the contact is closed. ...