  • Page 2 – *This accessory is not covered by the approval.; Wiring Details; Observe proper polarity.
  • Page 3 – Close the sensor and apply power to the sensor. Initialization is
  • Page 6 – RELAY OPERATION; TROUBLESHOOTING; Walk test; SPECIFICATIONS
  • Page 7 – printing the document!
Loading the manual

- 1 -

DT8360CM / DT8360ACM DUAL TEC® Ceiling Mount Motion

Sensor

Installation Instructions

1. Select the Mounting Location

Mounting location guidelines:

The range is obtained at a mounting height of 2.4m (8’) to 8m (26’). Max. detection range at 8m (26’) is Ø 21m (70’).

Allow a clear line-of-sight to all areas to protect.

Avoid mounting anything within 30cm (12”) in front of the sensor.

Do not directly face windows.

Avoid close proximity to moving machinery, fluorescent lights, and heating/cooling sources. Avoid use in turbulent air.

Not for use in applications with pets.

2. Open the Sensor

1.

Turn the arrow to point to the Unlock symbol.

2.

Press firmly on housing latch.

3.

Gently separate the front and rear housing.







"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - *This accessory is not covered by the approval.; Wiring Details; Observe proper polarity.

- 2 - 3. Mount the Sensor [A] = Fixed mounting holes [B] = Adjustable mounting slots from 61mm-85mm (2.4 ” -3.3 ” ) [C] = Tamper hole *This accessory is not covered by the approval. 4. Wire the Sensor Wiring Details • Observe proper polarity. • If not using the integrated EOL resistors, set all swit...

Page 3 - Close the sensor and apply power to the sensor. Initialization is

- 3 - 5. Sensor Components and Settings 6. Walk Test the Sensor and Adjust as Needed 1. Close the sensor and apply power to the sensor. Initialization is complete when the LED stops flashing slowly (about 30 seconds). 2. Walk through the detection area and observe the LED. 3. Adjust the microwave ra...

Page 6 - RELAY OPERATION; TROUBLESHOOTING; Walk test; SPECIFICATIONS

- 6 - REMOTE LED ENABLE (LED INPUT) (DT8360ACM only) The LED input terminal allows the LED to be remotely enabled. To use this feature, the LED DIP switch (switch 2) must be OFF, allowing the LED to operate based on the voltage level connected to the LED Input (see Wiring Details ). Switch 2 LED Inp...