Honeywell D896- Manual

Honeywell D896

Honeywell D896– Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
Page: / 12

Table of Contents:

  • Page 2 – D896 AUTOMATIC VENT DAMPER; ORDERING INFORMATION; TRADELINE® Models; Standard Models
  • Page 3 – APPLICATION
  • Page 4 – INSTALLATION; When Installing this Product...; CAUTION; Location; WARNING; Mounting
  • Page 5 – Wiring
  • Page 7 – Snap-TiteTM Connector Release; SETTINGS; OPERATION AND CHECKOUT; Operation
  • Page 8 – Checkout; Heating; Cooling; TROUBLESHOOTING
  • Page 9 – INSTRUCTIONS TO THE HOMEOWNER
  • Page 10 – ANSI STANDARDS
Loading the manual

PRODUCT DATA

® U.S. Registered Trademark
Copyright © 1997 Honeywell Inc. • All Rights Reserved

D896 Automatic Vent Damper

GENERAL

D896 Automatic Vent Dampers are used with atmospheric
type, gas-fired equipment to reduce home heating losses by
closing off the vent between heat cycles.

FEATURES

4-wire plug receptacle.

Includes wiring harness on select models to fit plug
receptacle onto S86/S8600/S8610/S8620 /L7148/L8148
or Penn Baso G60 or G66.

For use only on atmospheric type gas-fired furnaces
and boilers equipped with draft hoods.

Applicable to direct spark ignition (DSI), intermittent
pilot (IP), hot surface ignition (HSI), and standing pilot
systems.

Ambient temperature range 32

°

F (0

°

C) to 150

°

F (65

°

C).

Requires dual automatic combination gas control
valve or two separate single function main gas valves.

Interlock switch provides safe operation; burner fires
only with damper in open position.

24V operation for easy, low-cost wiring.

Visual indicator shows damper position.

30-second nominal closing time for optimum energy
savings.

Quiet motor and relay.

Wiring harnesses available separately to fit a variety of
applications.

68-0186

Contents

General ...............................................................................

1

Features .............................................................................. 1
Specifications ......................................................................

2

Ordering Information ...........................................................

2

Application ........................................................................... 3
Installation ........................................................................... 4
Settings ...............................................................................

7

Operation and Checkout .....................................................

7

Troubleshooting ...................................................................

8

Instructions to the Homeowner ...........................................

9

ANSI Standards .................................................................. 10

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Other Manuals for Honeywell D896

Summary

Page 2 - D896 AUTOMATIC VENT DAMPER; ORDERING INFORMATION; TRADELINE® Models; Standard Models

D896 AUTOMATIC VENT DAMPER 68-0186 2 ORDERING INFORMATION When purchasing replacement and modernization products from your TRADELINE® wholesaler or distributor, refer to theTRADELINE® Catalog or price sheets for complete ordering number. If you have additional questions, need further information, or...

Page 3 - APPLICATION

D896 AUTOMATIC VENT DAMPER 68-0186 3 NOTE: A minimum of a 30 VA transformer must be usedwhen D896 is installed with S86/S8600/S8610/S8620. Electrical Connections:Four-wire plug receptacle. Thermostat Anticipator Setting:0.13A. Operating Times: Approximate Damper Opening Time: 30 seconds.Approximate ...

Page 4 - INSTALLATION; When Installing this Product...; CAUTION; Location; WARNING; Mounting

D896 AUTOMATIC VENT DAMPER 68-0186 4 IMPORTANT 1. The atmospheric draft hood outlet area must besmaller or equal to the inlet area of the damperassembly. 2. If a second gas valve needs to be installed, referto the gas valve manufacturer instructions for theprocedure. 3. Using a dual automatic valve ...

Other Honeywell Models