Table of Contents:

  • Page 2 – WIRING; CAUTION; Disconnect power before wiring.
  • Page 3 – DELUXE ZONING HEAT PUMP THERMOSTAT; Mounting Thermostat; Press lower edge of case to close and latch.
  • Page 4 – Using Thermostat Keys; NOTE: Always press the keys with your fingertip or sim-; SETTINGS; System and Fan Settings; System settings control thermostat operation:; Temperature Settings
  • Page 5 – INSTALLER SETUP; IMPORTANT; S e t D a y / T i m e; Hold for; E m H t
  • Page 8 – Setting Current Day and Time
  • Page 9 – A u x H t
  • Page 10 – THERMOSTAT INFORMATION; Outdoor Temperature Sensor; Keys to
  • Page 11 – Symptom
Loading the manual

® U.S. Registered Trademark
Copyright © 2003 Honeywell •

• All Rights Reserved

INSTALLATION INSTRUCTIONS

69-1414-2

T8611G Chronotherm

®

Deluxe Zoning

Heat Pump Thermostat

APPLICATION

The T8611G Chronotherm® Deluxe Zoning Heat Pump Thermostat provides electronic control of 24 Vac zoned heat
pump systems. Refer to Table 1 and Table 2 for a general description of the thermostat and zoning applications.

Table 1. Description of T8611 Thermostats.

Table 2. T8611 Zoning Applications.

MERCURY NOTICE

If this control is replacing a control that contains
mercury in a sealed tube, do not place your old
control in the trash. Dispose of properly.

Contact your local waste management authority
for instructions regarding recycling and the
proper disposal of the old control.

INSTALLATION

When Installing this Product...

1.

Read these instructions carefully. Failure to follow
the instructions can damage the product or cause
a hazardous condition.

2.

Check the ratings given in the instructions and on
the product to make sure the product is suitable for
your application.

3.

Installer must be a trained, experienced service
technician.

4.

After completing installation, use these instructions
to check out the product operation.

Location

Install the thermostat about 1.5m (5 ft) above the floor in
an area with good air circulation at average temperature.
See Fig. 1.

Do not install the thermostat where it can be affected by:
— drafts, or dead spots behind doors and in corners.
— hot or cold air from ducts.
— radiant heat from sun or appliances.
— concealed pipes and chimneys.
— unheated (uncooled) areas such as an outside wall

behind the thermostat.

Wallplate Installation

The thermostat can be mounted horizontally on the wall
or on a 2 in. x 4 in. (50.8 mm x 101.6 mm) wiring box.
Position wallplate horizontally on the wall or on a
2 in. x 4 in. (50.8 mm x 101.6 mm) wiring box.

1.

Position and level the wallplate (for appearance
only). The thermostat functions correctly even
when not level.

2.

Use a pencil to mark the mounting holes.
See Fig. 2.

Model

Power Method

Changeover

System Selection

Fan Selection

T8611G2051

Hardwired

Automatic or manual

Heat-Off-Cool-Auto-Em. Heat

On-Auto

Model

TotalZone

®

EMM-3U

EMM-3

T8611G2051

Yes

Yes

No

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - WIRING; CAUTION; Disconnect power before wiring.

T8611G CHRONOTHERM ® DELUXE ZONING HEAT PUMP THERMOSTAT 69-1414—2 2 Fig. 1. Typical location of thermostat. Fig. 2. Mounting the wallplate. 3. Remove the wallplate from the wall and drill two 3/16 inch (76 mm holes) in the wall (if drywall) as marked. For firmer material such as plaster, drill two 7...

Page 3 - DELUXE ZONING HEAT PUMP THERMOSTAT; Mounting Thermostat; Press lower edge of case to close and latch.

T8611G CHRONOTHERM ® DELUXE ZONING HEAT PUMP THERMOSTAT 3 69-1414—2 Fig. 4. Typical wiring diagram for T8611G on TotalZone® Control Panel. Fig. 5. Correct wiring technique. Mounting Thermostat 1. Engage tabs at the top of the thermostat and wall-plate. See Fig. 6. Be sure to align subbase pins to av...

Page 4 - Using Thermostat Keys; NOTE: Always press the keys with your fingertip or sim-; SETTINGS; System and Fan Settings; System settings control thermostat operation:; Temperature Settings

T8611G CHRONOTHERM ® DELUXE ZONING HEAT PUMP THERMOSTAT 69-1414—2 4 Fig. 7. T8611G key locations and descriptions. Using Thermostat Keys The thermostat keys are used to:• set current day and time,• program times and setpoints for heating and cooling,• temporarily override program temperatures, • dis...

Other Honeywell Models