Honeywell CHRONOTHERM III T8611G- User Manual

Honeywell CHRONOTHERM III T8611G

Honeywell CHRONOTHERM III T8611G– User Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
Page: / 8

Table of Contents:

  • Page 2 – FRONT VIEW OF
  • Page 6 – Fig. 9—Mounting the thermostat on subbase.; Checkout; CAUTION
  • Page 7 – Perform the following test as a check of all thermostat
  • Page 8 – Helping You Control Your World; -DIGIT CODE EXPLANATION; Refer to Owner’s Manual for programming instructions and
Loading the manual

J.H. • 3-92 • © Honeywell Inc. 1992 • Form Number 69-0348—1

T8611G,R

Chronotherm III

Fuel Saver Thermostats

TABLE 1—Thermostat Models.

Thermostat

Stages

Switching

LEDs

Changeover

Terminals

Comments

See Fig.

Heat

Cool

System

Fan

T8611G

2

1

EM.HEAT-

ON-

EM.HT,

Auto

R, C/X, L,

4

HEAT-OFF-

AUTO

AUX.HT.

W

2

,E,G,O,

AUTO-COOL

B,Y,X

2

,X

1

T8611R

2

1

EM.HEAT-

ON-

EM.HT.,

Manual

R,C/X,L,

5

HEAT-OFF-

AUTO

AUX.HT.

W

2

,E,W

1

,G,

COOL

O,B,Y,P

2

1

EM.HEAT-

ON-

EM.HT.

Manual

R,B,X,W

2

,

Exact

6

HEAT-OFF-

AUTO

E,W

1

,G,O,

replacement

COOL

H,Y

1

for York
model no.
2ET11700224.

Installation

WHEN INSTALLING THIS PRODUCT...

1. Read these instructions carefully. Failure to allow

them could damage the product or cause a hazardous condi-
tion.

2. Check the ratings on the product to make sure the

product is suitable for your application.

3. Installer must be a trained, experienced service techni-

cian.

4. Allow thermostat to warm to room temperature before

operating.

5. After installation is complete, check out product op-

eration as provided in these instructions.

CAUTION

1. Disconnect power supply to prevent electri-

cal shock or equipment damage.

2. After wiring is complete, push excess wire

back into the hole, and plug hole with
nonhardening caulk, putty or insulation to
prevent drafts from affecting thermostat op-
eration.

LOCATION

Install thermostat and subbase about 5 ft. [1.5m] above the

floor in an area with good air circulation at room temperature.

Do not install the thermostat where it may be affected

!

Application

These thermostats provide energy saving control for a 24

Vac multistage heat pump heating/cooling system as indi-
cated in Table 1 and are powered directly from the control
transformer. All models have 5-1-1 programming.

As long as AC power is continuously available to trans-

former, the thermostat will be compatible with most control
systems.

The T8611G,R models include SYSTEM and ENRG

SAV LEDs near the top front of the thermostat. The SYS-
TEM LED lights when the thermostat is signaling for heating
or air conditioning. The ENGR SAV LED lights during the
LEAVE and SLEEP periods.

The AUX. HT., EM. HT., and CHECK LEDS are located

near the bottom center of the subbase. See Table 1. The AUX.
HT. LED lights whenever the thermostat is calling for
operation of the backup or auxiliary heater. Backup (auxil-
iary) heat is more expensive to operate than the heat pump and
typically is used only when the heat pump is unable to handle
the load. The EM. HT. LED lights whenever the thermostat
system switch is in the EM. HT. position. The CHECK LED
lights when something needs to be checked to maintain
efficient operation of the system. Consult heat pump equip-
ment literature to determine specific meaning of this LED.

Heat and cool anticipation is fixed in all models; no

adjustment is necessary. Cycle rates are adjustable for auxil-
iary heating stage.

TRADELINE

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - FRONT VIEW OF

2 by— —drafts or dead spots behind doors, in corners or under cabinets. —hot or cold air from ducts.—radiant heat from sun or appliances—concealed pipes and chimneys.—unheated (uncooled) areas behind the thermostat, such as an outside wall. IF REPLACING AN EXISTING THERMOSTAT Turn off power to therm...

Page 6 - Fig. 9—Mounting the thermostat on subbase.; Checkout; CAUTION

Fig. 9—Mounting the thermostat on subbase. When the batteries are low, the display will flash REPL BAT. Homeowner will have 20-30 seconds to replace batter-ies after removing batteries from thermostat. After 20-30seconds, it will be necessary to reprogram. REPL BATindication will be disappear when t...

Page 7 - Perform the following test as a check of all thermostat

7 69-0348—1 mask no. and System Press Look for this Switch This Response Position Key Key Down Key Released OFF 03 Blank 07 Blank 15 Blank COOL or 15 Cooling, fan and 15 Cooling, fan and OFF 06 Blank 02 Blank 05 Blank 04 Blank 01 Blank 00 Blank 12 See note A OFF 08 Blank 13 Microprocessor 09 Blank 1...

Other Honeywell Models