Honeywell C7089- User Manual

Honeywell C7089

Honeywell C7089– User Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
Page: / 12

Table of Contents:

  • Page 2 – Wiring; CAUTION
  • Page 5 – NOTICE D'INSTALLATION; Capteur extérieur; APPLICATION; INSTALLATION; MISE EN GARDE
  • Page 6 – Câblage; AVERTISSEMENT
  • Page 7 – ÉTALONNAGE
  • Page 9 – INSTRUCCIONES DE INSTALACIÓN; Sensor exterior; APLICACIÓN; INSTALACIÓN; PRECAUCIÓN
  • Page 10 – Cableado
Loading the manual

® U.S. Registered Trademark
Copyright © 2004 Honeywell International Inc. •

• All Rights Reserved

69-1709EFS

INSTALLATION INSTRUCTIONS

C7089

Outdoor Sensor

(USE WITH TH8000 AND TH7000 THERMOSTATS)

APPLICATION

This C7089 Outdoor Sensor is used with theTH8000 and
TH7000 Thermostat families.

SPECIFICATIONS

Operating Ambient Temperature Range:

-40 to 120°F (-40 to 49°C).

Display Range:

-40 to 127°F (-40 to 53°C).

Sensor Accuracy:

+/-1.5°F at 70°F (+/-.84 at 21°C)

Operating Relative Humidity:

5% to 95% non-condensing.

Dimensions in in. (mm):

2-1/4 (57) x 3/8 (10) with 60 (1524) leadwires.

INSTALLATION

When Installing this Product…

1.

Read

these instructions carefully. Failure to follow

them could damage the product or cause a hazard-
ous condition.

2.

C

heck the ratings given in the instructions and on

the product to make sure the product is suitable for
your application.

3.

In

staller must be a trained, experienced service

technician.

4.

A

fter installation is complete, check out product

operation as provided in these instructions.

CAUTION

Electrical Shock Hazard.
Can cause electrical shock or equipment
damage.

Disconnect power supply before connecting
wiring.

Location and Mounting (Fig. 1)

Mount the sensor where:
• cannot tamper with settings.
• there is good air circulation.
• it can measure true outdoor ambient temperature.
• surface is flat.
• wire distance between C7089 and thermostat is less

than 200 feet.

Do

not

mount the sensor:

• in direct sunlight.
• where hot or cold air blows on the sensor. Discharge

line from an outdoor compressor unit, vent or fan
causes inaccurate temperature readings.

• where snow, ice or debris can cover it.

Use the following steps to mount the sensor:

1.

R

emove the sensor from the mounting clip.

2.

Mark the area on the location selected for
mounting the sensor mounting clip.

3.

Mount the clip.

Fig. 1. Typical locations for outdoor sensor.

M7514

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Other Manuals for Honeywell C7089

Summary

Page 2 - Wiring; CAUTION

C7089 OUTDOOR SENSOR 69-1709EFS 2 Wiring CAUTION Electrical Interference (Noise) Hazard.Can cause erratic system operation. Keep wiring at least one foot away from large inductive loads such as motors, line starters, lighting ballasts and large power distribution panels. Use shielded cable to reduce...

Page 5 - NOTICE D'INSTALLATION; Capteur extérieur; APPLICATION; INSTALLATION; MISE EN GARDE

® Marque de commerce déposée aux É.-U.Copyright © 2004 Honeywell International Inc. • Tous droits réservés • 69-1709EFS NOTICE D'INSTALLATION C7089 Capteur extérieur (À UTILISER AVEC LES THERMOSTATS TH8000 ET TH7000) APPLICATION Le capteur extérieur C7089 est utilisé avec les thermostats des gammes ...

Page 6 - Câblage; AVERTISSEMENT

C7089 CAPTEUR EXTÉRIEUR 69-1709EFS 2 Câblage AVERTISSEMENT Risque d’interférences électriques.Peut provoquer le fonctionnement erratique du système. Tenir le fil à au moins 30 cm de distance de charges inductives importantes tels que des moteurs, des démarreurs, des ballasts d’éclairage et de grands...