Installation Instructions for the
Honeywell Zephyr
TM
Digital Airflow Sensors
HAF Series–High Accuracy
±50 SCCM to ±750 SCCM
50045178
Issue E
CAUTION
IMPROPER USE
Do not use to sense liquid flow.
Failure to comply with these instructions may result in
product damage.
CAUTION
IMPROPER CLEANING
• Avoid cleaning the sensor; however, if it must be cleaned use
isopropyl alcohol and dry the device thoroughly before use.
Cap the ports or connect housing to the ports before cleaning
the sensor with alcohol. Using alcohol may remove the text on
the sensor label; however, the label ID is hard coded inside the
sensor.
• Do not use III Tri-chloroethane, methylene chloride, methyl
pyrrolidone, or any oxidizing type acid such as formic acid.
• Do not use ultrasonic cleaning.
Failure to comply with these instructions may result in
product damage.
NOTICE
Absolute maximum ratings are the extreme limits that the device
will withstand without damage to the device. However, the
electrical and mechanical characteristics are not guaranteed as
the maximum limits (above recommended operating conditions)
are approached, nor will the device necessary operate at
absolute maximum ratings.
Table 2. Operating Specifications
Characteristic
Parameter
Notes
Supply voltage:
3.3 Vdc
5.0 Vdc
3.3 Vdc ±10%
5.0 Vdc ±10%
—
Power:
3.3 Vdc
5.0 Vdc
40 mW max.
65 mW max.
1
Compensated temperature
range
0 °C to 50 °C
[32 °F to 122 °F]
2
Operating temperature
range
-20 °C to 70 °C
[-4 °F to 158 °F]
—
Warm-up time
30 ms
3
Calibration media
gaseous nitrogen
4
Bus standards
I
2
C fast mode (up to 400 kHz)
5
Reverse polarity protection
no
—
Notes:
1. Maximum power: Is measured under the conditions of the highest supply
voltage, Vsupply + 10%, 70 °C, full scale flow and with the minimum load
specified for that supply voltage.
2. Custom and extended compensated temperature ranges are possible.
Contact Honeywell for details.
3. Warm-up time: The time to the first valid flow measurement after power is
applied.
4. Default calibration media is dry nitrogen gas. Please contact Honeywell for
other calibration options.
5. Refer to the Technical Note “I
2
C Communications with Honeywell Digital
Airflow Sensors” for I
2
C protocol information.
Table 1. Absolute Maximum Ratings
Characteristic
Parameter
Supply voltage
-0.3 Vdc to 6.0 Vdc
Voltage on I/O output pin
-0.3 Vdc to Vsupply
Storage temperature range
-40 °C to 125 °C [-40 °F to 257
°F]
Maximum flow change
5.0 SLPM/s
Maximum common mode pres
sure
25 psi at 25 °C [77 °F]
Maximum flow
10 SLPM
CAUTION
LARGE PARTICULATE DAMAGE
Use a 5-micron filter upstream of the sensor to keep media flow
through the sensor free of condensing moisture and particulates.
Large, high-velocity particles or conductive particles may
damage the sensing element.
Failure to comply with these instructions may result in
product damage.
GENERAL INFORMATION
Table 3. Environmental Characteristics
Characteristic
Parameter
Humidity
0% to 95% RH, non-condensing
Shock
100 g, 11 ms
Vibration
15 g at 20 Hz to 2000 Hz
ESD
Class 3B per MIL-STD 883G
Table 4. Wetted Materials
Characteristic
Parameter
Covers
high temperature polymer
Substrate
PCB
Adhesives
epoxy
Electronic components
silicon, gold
Compliance
RoHS, WEEE
Table 5. Recommended Mounting and Implementation
Characteristic
Parameter
Mounting screw:
size
torque
5-40
0.68 N m [6 in lb]
Silicone tubing for long
port style
70 durometer; 0.125 inch inside
diameter, 0.250 inch outside diameter
O-ring:
short port style
long port style
AS568A, Size 7, Silicone, Shore A 70
AS568A, Size 10, Silicone, Shore A 70
Filter
5-micron filter upstream of sensor
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Other Manuals for Honeywell 5207
Summary
2 Honeywell Sensing and Control Honeywell Zephyr TM Digital Airflow Sensors HAF Series–High Accuracy±50 SCCM to ±750 SCCM Issue E 50045178 Figure 1. Wave Solder Profile 0 20 40 60 80 100 0 50 100 150 200 250 300 Time (s) Temperature (°C) Max. temp. = 243 °CMax. temp. = 205 °C Housing temp. (top of d...
Honeywell Sensing and Control 3 Honeywell Zephyr TM Digital Airflow Sensors HAF Series–High Accuracy±50 SCCM to ±750 SCCM Issue E 50045178 Figure 3. Mounting Dimensions (For reference only: mm [in].) LF: Long port, fastener mount SF: Short port, fastener mount Mounting Footprint Mounting Footprint 7...
4 Honeywell Sensing and Control Honeywell Zephyr TM Digital Airflow Sensors HAF Series–High Accuracy±50 SCCM to ±750 SCCM Issue E 50045178 Figure 3. Mounting Dimensions (continued) SS: Short port, snap mount 10 Table 5. Pinout Pin 1 Pin 2 Pin 3 Pin 4 SCL Vsupply ground SDA Mounting Footprint ;32576 ...