Heat & Glo 6000TRI-SP - Manual
Heat & Glo 6000TRI-SP – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 2 – Installers Guide; DO NOT; Owners Guide; ALERTED; SAFETY AND WARNING INFORMATION
- Page 3 – TABLE OF CONTENTS
- Page 4 – Log set assembly; Service Parts
- Page 5 – IN T E R MIT T E N T P IL OT IGN IT ION (IP I)* / IP I AL LU MAGE S E U L E ME N T; Service Parts List / Liste des pièces de rechange; L'information fournie dans cette brochure
- Page 6 – Intermittent Pilot Ignition
- Page 7 – PIÈ C E; Standing Pilot Ignition
- Page 8 – Appliance Certification; The Heat & Glo fireplace models discussed in this; Certification; Underwriters Laboratories; Installation Codes
- Page 9 – Getting Started; Introducing the Heat & Glo Gas Fireplaces; Pre-install Preparation; Do not install any
- Page 11 – Installing the Fireplace; Step 1. Locating the Fireplace; Vertical Sections; Constructing the Fireplace Chase
- Page 12 – Framing Dimensions; Step 2. Framing the Fireplace
- Page 14 – Step 3. Installing the Vent System; SERIES
- Page 15 – STRAIGHT UP; VERTICAL VENTING; Flue Restrictor Instructions; Figure 8. Flue Restrictor; On vertical venting
- Page 16 – HORIZONTAL VENTING; Figure 11. Corner Installation; Match the amount of vertical you have in the sys-; . Center the Flue Restrictor on vent and secure in; Figure 9
- Page 17 – On vertical venting configurations where; Figure 12. Venting with One 90° Elbow; elbow is first attached to the unit,
- Page 18 – ELBOWS
- Page 19 – Figure 16. Venting with three 90° elbows; V H H + H
- Page 20 – Figure 17. Venting with three 90° elbows
- Page 21 – B. Installing Vent Components; Venting Out Rear
- Page 23 – REQUIRED
- Page 24 – Figure 28. Trapezoid Termination Cap; If the area above the ceiling is; NOT; an attic, position and; IS; an attic, position and secure; Figure 27. Attic Firestop
- Page 25 – = AREA WHERE TERMINAL IS NOT PERMITTED; Figure 29. Vent Termination Minimum Clearances; public
- Page 27 – Step 6. The Gas Control Systems; The types of gas control systems used with this model are; Step 5. Installing the Optional Heat-Zone Kit; There must be NO INSULATION or other com-; Do this; FORE; final positioning of the fireplace.; Standing Pilot Ignition System
- Page 28 – Figure 35. Gas Supply Line; Step 7. The Gas Supply Line; Pressure
- Page 30 – Step 9. Wiring the Fireplace; This appliance
- Page 31 – require; Figure 40. Sealant Material; FINISH WALL MATERIAL MAY BE; There are 3 metal tabs holding the non-combustible
- Page 33 – Step 12. Before Lighting the Fireplace
- Page 34 – Maintaining and Servicing Your Fireplace; Fireplace Maintenance; Placing; Step 13. Lighting the Fireplace
Heat & Glo • 6000TRI-IPI, 6000TRI-SP • 385-901 Rev. F • 5/05
1
- Do not store or use gasoline or other flam-
mable vapors and liquids in the vicinity of this
or any other appliance.
-
What to do if you smell gas
• Do not try to light any appliance.
• Do not touch any electrical switch.
• Do not use any phone in your building.
• Immediately call your gas supplier from a
neighbor's phone. Follow the gas supplier's
instructions.
• If you cannot reach your gas supplier, call
the fire department.
- Installation and service must be performed by a
qualified installer, service agency, or the gas
supplier.
Installers Guide
W A R N I N G : I M P R O P E R I N S TA L L A -
TION, ADJUSTMENT, ALTERATION,
S E R V I C E O R M A I N T E N A N C E C A N
CAUSE INJURY OR PROPERTY DAM-
AGE. REFER TO THIS MANUAL. FOR
ASSISTANCE OR ADDITIONAL INFOR-
MATION CONSULT A QUALIFIED IN-
STALLER, SERVICE AGENCY, OR THE
GAS SUPPLIER.
Underwriters
Laboratories Listed
READ THIS MANUAL BEFORE INSTALLING OR
OPERATING THIS APPLIANCE. THIS INSTALLERS
GUIDE MUST BE LEFT WITH APPLIANCE FOR
FUTURE REFERENCE.
1. This appliance may be installed in an af-
termarket, permanently located, manufac-
tured (mobile) home, where not prohibited
by local codes.
2. This appliance is only for use with the type
of gas indicated on the rating plate. This
appliance is not convertible for use with
other gases, unless a certified kit is used.
Please contact your Heat & Glo dealer with any
questions or concerns. For the number of your nearest
Heat & Glo dealer, please call 1-888-427-3973.
Printed in U.S.A. Copyright 2005,
Heat & Glo, a brand of Hearth & Home Technologies Inc.
20802 Kensington Boulevard, Lakeville, MN 55044
WARNING: IF THE INFORMATION
IN THESE INSTRUCTIONS IS NOT
FOLLOWED EXACTLY, A FIRE OR
EXPLOSION MAY RESULT CAUS-
ING PROPERTY DAMAGE, PER-
SONAL INJURY, OR DEATH.
This product is covered by one or more of the following patents: (United States) 4,112,913; 4,408,594; 4,422,426; 4,424,792; 4,520,791; 4,793,322;
4,852,548; 4,875,464; 5,000,162; 5,016,609; 5,076,254 5,191,877; 5,218,953; 5,328,356; 5,429,495; 5,452,708; 5,542,407; 5,613,487; (Australia)
543790; 586383; (Canada) 1,123,296; 1,297,746; 2,195,264; (Mexico) 97-0457; (New Zealand) 200265; or other U.S. and foreign patents pending.
Models:
6000TRI-IPI
6000TRI-SP
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
Heat & Glo • 6000TRI-IPI, 6000TRI-SP • 385-901 Rev. F • 5/05 2 These units MUST use one of the vent systems described in the Installing the Fireplace section ofthe Installers Guide . NO OTHER vent systems or components MAY BE USED. This gas fireplace and vent assembly MUST be vented directly to ...
Heat & Glo • 6000TRI-IPI, 6000TRI-SP • 385-901 Rev. F • 5/05 3 TABLE OF CONTENTS Safety and Warning Information ................................................ 2 Service Parts Lists ..................................................................... 4 Section 1: Approvals and Codes .............
Heat & Glo • 6000TRI-IPI, 6000TRI-SP • 385-901 Rev. F • 5/05 4 * Part number list on following page. * La liste des numéros de pièce se trouve à la page suivante. 16 4 5 14 1 5 1 3 2 3 1 1 7 10 7 9 8 11 12 6 Log set assembly 1 8 (NG, LP) Exploded Parts Diagram(GN, PL) Vue éclatée des pièces Serv...