Heat & Glo BE-41 - Manual
Heat & Glo BE-41 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 2 – ALERTED; SAFETY AND WARNING INFORMATION
- Page 3 – TABLE OF CONTENTS
- Page 4 – Service Parts; La liste des numéros de pièce se; Log Set Assembly
- Page 5 – STANDING PILOT IGNITION ONLY / ALLUMAGE UNE VEILLEUSE SEULEMENT; BE-41 Service Parts List / Liste des pièces de rechange
- Page 6 – Appliance Certification; Installers; Certification; Approvals and; High Altitude Installations; Systems registered
- Page 7 – Getting Started; Introducing the Heat-N-Glo Gas Fireplaces; Pre-install Preparation; Installers Guide
- Page 8 – ANY SUCH ACTION MAY POSSIBLY CAUSE A FIRE
- Page 9 – Installing the Fireplace; Step 1. Locating the Fireplace; Vertical Sections
- Page 10 – Figure 3. Framing Dimensions; Step 2. Framing the Fireplace; Fireplace framing can be built before or after the fireplace is; VENT FRAMING HOLES FOR
- Page 11 – Figure 4. D-Series Direct Vent Component Specifications
- Page 12 – Step 3. Installing the Vent System
- Page 13 – HORIZONTAL VENTING; On vertical venting configurations where the vertical; STRAIGHT UP; Center the vertical baffle over the 5 exhaust pipe.
- Page 15 – ELBOWS
- Page 16 – Figure 13. Venting with three 90° elbows; V H H + H
- Page 17 – Figure 14. Venting with three 90° elbows
- Page 18 – B. Installing Vent Components; Venting Out Rear
- Page 19 – NOTE: Model DVK-01TRD does not need an exterior
- Page 20 – MUST BE; REQUIRED
- Page 21 – NOTE: Keep insulation away from the vent pipe at least
- Page 24 – Securing the Fireplace; Leveling and Securing of a Fireplace; Step 5. The Gas Control Systems; WARNING: THIS UNIT IS NOT FOR USE WITH; Standing Pilot Ignition; Standing Pilot Ignition System
- Page 25 – Figure 29. Gas Supply Line; Step 6. The Gas Supply Line; NOTE: Have the gas supply line installed in accordance; Step 7. Gas Pressure Requirements; Pressure
- Page 26 – Step 8. Wiring the Fireplace; This appliance
- Page 27 – and Ember Material
- Page 28 – BEFORE; FIRING THE UNIT; Log Placement Tabs; Positioning the Logs
- Page 30 – Step 11. Before Lighting the Fireplace; Step 12. Lighting the Fireplace; CAUTION: IT IS STRONGLY RECOMMENDED THAT
- Page 31 – Maintaining and Servicing Your Fireplace; Fireplace Maintenance
1
- Do not store or use gasoline or other flam-
mable vapors and liquids in the vicinity of this
or any other appliance.
-
What to do if you smell gas
Do not try to light any appliance.
Do not touch any electrical switch.
Do not use any phone in your building.
Immediately call your gas supplier from a
neighbor's phone. Follow the gas supplier's
instructions.
If you cannot reach your gas supplier, call
the fire department.
- Installation and service must be performed by a
qualified installer, service agency, or the gas
supplier.
Installers Guide
WARNING: IMPROPER INSTA L L A -
TION, ADJUSTMENT, ALTERATION,
SERVICE OR MAINTENANCE CAN
CAUSE INJURY OR PROPERTY DAM-
AGE. REFER TO THIS MANUAL. FOR
ASSISTANCE OR ADDITIONAL INFOR-
MATION CONSULT A QUALIFIED IN-
STALLER, SERVICE AGENCY, OR THE
GAS SUPPLIER.
Underwriters
Laboratories Listed
394-900B 9/00
READ THIS MANUAL BEFORE INSTALLING OR
OPERATING THIS APPLIANCE. THIS
INSTALLERS
GUIDE
MUST BE LEFT WITH APPLIANCE FOR
FUTURE REFERENCE.
1. This appliance may be installed in an af-
termarket, permanently located, manufac-
tured (mobile) home, where not prohibited
by local codes.
2. This appliance is only for use with the type
of gas indicated on the rating plate. This
appliance is not convertible for use with
other gases, unless a certified kit is used.
Please contact your Heat-N-Glo dealer for any
questions or concerns. For the number of your
nearest Heat-N-Glo dealer, please call 952-985-6000.
Printed in U.S.A. Copyright 2000,
Heat-N-Glo, a division of Hearth Technologies Inc.
20802 Kensington Boulevard, Lakeville, MN 55044
WARNING: IF THE INFORMATION
IN THESE INSTRUCTIONS IS NOT
FOLLOWED EXACTLY, A FIRE OR
EXPLOSION MAY RESULT CAUS-
ING PROPERTY DAMAGE, PER-
SONAL INJURY, OR DEATH.
This product is covered by one or more of the following patents: (United States) 4,112,913; 4,408,594; 4,422,426; 4,424,792; 4,520,791; 4,793,322;
4,852,548; 4,875,464; 5,000,162; 5,016,609; 5,076,254 5,191,877; 5,218,953; 5,328,356; 5,429,495; 5,452,708; 5,542,407; 5,613,487; (Australia)
543790; 586383; (Canada) 1,123,296; 1,297,746; 2,195,264; (Mexico) 97-0457; (New Zealand) 200265; or other U.S. and foreign patents pending.
Model:
BE-41
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
2 These units MUST use one of the vent systems described in the Installing the Fireplace section of the Installers Guide . NO OTHER vent systems or components MAY BE USED . This gas fireplace and vent assembly MUST be vented directly to the outside and MUST NEVER be attached to a chimney serving a s...
3 TABLE OF CONTENTS Safety and Warning Information ................................................ 2 Service Parts Lists ..................................................................... 4 Section 1: Approvals and Codes ............................................... 6 Approval Listings and Cod...
4 BE-41 (NG, LP) Exploded Parts Diagram / Vue éclatée des pièces Service Parts * Part number list on following page.* La liste des numéros de pièce se trouve à la page suivante. 2 3 1 8 9 10 5 7 6 Log Set Assembly 4