  • Page 2 – ALERTED; SAFETY AND WARNING INFORMATION; DO NOT
  • Page 3 – Table of Contents
  • Page 4 – Part number list on following page.; Log Set Assembly; Service Parts; EVEREST
  • Page 5 – Service Parts List; supply serial and model numbers to ensure correct service parts.; ACCESSORIES
  • Page 6 – Appliance Certification; Installers; Certification; Approvals and Codes; High Altitude Installations
  • Page 7 – Getting Started; Introducing the Heat & Glo Gas Fireplaces; Pre-install Preparation; Installers Guide; Do not install any; Warranty
  • Page 8 – Diagram of the Everest
  • Page 9 – Installing the Fireplace; Step 1. Locating the Fireplace; Vertical Sections
  • Page 10 – Vent Components and Terminations; Step 3. Installing the Vent System; ING SYSTEMS OR COMPONENTS MAY BE USED; Identifying Vent Components; MUST BE; To Unit
  • Page 11 – STRAIGHT UP; VERTICAL VENTING; CAP
  • Page 12 – Venting with One 90° Elbow; elbow is first attached to the unit, the
  • Page 13 – Venting with Two 90° Elbows
  • Page 14 – Venting with three 90° elbows
  • Page 15 – Figure 10. Vertical Baffle; B. Installing Vent Components; Assembling Vent Sections; and; Vent Termination
  • Page 16 – To Install the Heat Shield:
  • Page 17 – For Vertical Runs; REQUIRED
  • Page 18 – Figure 17. Trapezoid Termination Cap
  • Page 19 – = AREA WHERE TERMINAL IS NOT PERMITTED; public; Alcove Applications
  • Page 20 – For Vertical Terminations
  • Page 21 – Figure 21. Intermittent Pilot Ignition; Step 5. The Gas Control Systems; The gas control system used with this model is
  • Page 22 – Figure 22. Gas Supply Line; Step 6. The Gas Supply Line; Pressure
  • Page 23 – Step 8. Wiring the Fireplace; Appliance Requirements
  • Page 24 – Hearth Extensions; require; Figure 25. Sealant Material
  • Page 25 – Installing the Trim; MUST NEVER; overlap onto the front face. The joints; Positioning the Logs; Save the log instructions with this manual.; Placing the Rock; • Pull the six glass latches out of the groove on the glass; Glass Specifications: CERAMIC
  • Page 26 – Step 11. Before Lighting the Fireplace; Step 12. Lighting the Fireplace
  • Page 27 – Fireplace Maintenance
Loading the manual

Heat & Glo • Everest • 750-900 Rev. L • 1/06

1

Model:

Everest

Installers Guide

Underwriters

Laboratories Listed

In the Commonwealth of Massachusetts:

• installation must be performed by a licensed

plumber or gas fitter;

• a CO detector shall be installed in the room

where the appliance is installed.

- Do not store or use gasoline or other flam-

mable vapors and liquids in the vicinity of this
or any other appliance.

-

What to do if you smell gas

• Do not try to light any appliance.

• Do not touch any electrical switch.

• Do not use any phone in your building.

• Immediately call your gas supplier from a

neighbor's phone. Follow the gas supplier's
instructions.

• If you cannot reach your gas supplier, call

the fire department.

- Installation and service must be performed by a

qualified installer, service agency, or the gas
supplier.

W A R N I N G : I M P R O P E R I N S TA L L A -
TION, ADJUSTMENT, ALTERATION,
S E R V I C E O R M A I N T E N A N C E C A N
CAUSE INJURY OR PROPERTY DAM-
AGE. REFER TO THIS MANUAL. FOR
ASSISTANCE OR ADDITIONAL INFOR-
MATION CONSULT A QUALIFIED IN-
STALLER, SERVICE AGENCY, OR THE
GAS SUPPLIER.

READ THIS MANUAL BEFORE INSTALLING OR
OPERATING THIS APPLIANCE. THIS INSTALLERS
GUIDE
MUST BE LEFT WITH APPLIANCE FOR
FUTURE REFERENCE.

1. This appliance may be installed in an af-

termarket, permanently located, manufac-
tured (mobile) home, where not prohibited
by local codes.

2. This appliance is only for use with the type

of gas indicated on the rating plate. This
appliance is not convertible for use with
other gases, unless a certified kit is used.

Please contact your Heat & Glo dealer with any
questions or concerns. For the number of your nearest
Heat & Glo dealer, please call 1-888-427-3973.

Printed in U.S.A. Copyright 2006

Heat & Glo, a brand of Hearth & Home Technologies Inc.
20802 Kensington Boulevard, Lakeville, MN 55044

WARNING: IF THE INFORMATION
IN THESE INSTRUCTIONS IS NOT
FOLLOWED EXACTLY, A FIRE OR
EXPLOSION MAY RESULT CAUS-
ING PROPERTY DAMAGE, PER-
SONAL INJURY, OR DEATH.

This product may be covered by one or more of the following patents: (United States) 4593510, 4686807, 4766876, 4793322, 4811534, 5000162, 5016609, 5076254, 5113843, 5191877, 5218953, 5263471,
5328356, 5341794, 5347983, 5429495, 5452708, 5542407, 5601073, 5613487, 5647340, 5688568, 5762062, 5775408, 5890485, 5931661, 5941237, 5947112, 5996575, 6006743, 6019099, 6048195,
6053165, 6145502, 6170481, 6237588, 6296474, 6374822, 6413079, 6439226, 6484712, 6543698, 6550687, 6601579, 6672860, 6688302B2, 6715724B2, 6729551, 6736133, 6748940, 6748942, 6769426,
6774802, 6796302, 6840261, 6848441, 6863064, 6866205, 6869278, 6875012, 6880275, 6908039, 6919884, D320652, D445174, D462436; (Canada) 1297749, 2195264, 2225408, 2313972; (Australia)
780250, 780403, 1418504 or other U.S. and foreign patents pending.

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - ALERTED; SAFETY AND WARNING INFORMATION; DO NOT

Heat & Glo • Everest • 750-900 Rev. L • 1/06 2 These units MUST use one of the vent systems described in the Installing the Fireplace section ofthe Installers Guide . NO OTHER vent systems or components MAY BE USED. This gas fireplace and vent assembly MUST be vented directly to the outside and ...

Page 3 - Table of Contents

Heat & Glo • Everest • 750-900 Rev. L • 1/06 3 Table of Contents Safety and Warning Information . .................................... 2 Service Parts Lists . ......................................................... 4 Section 1: Approvals and Codes . ................................... 6 Applia...

Page 4 - Part number list on following page.; Log Set Assembly; Service Parts; EVEREST

Heat & Glo • Everest • 750-900 Rev. L • 1/06 4 Part number list on following page. 1 3 5 10 8 7 9 11 Log Set Assembly 6 2 2 3 1 3 1 4 1 5 1 6 1 7 12 Back Log (not shown) 4 1 9 2 0 2 1 1 8 2 2 (NG, LP) Exploded Parts Diagram Service Parts EVEREST Beginning Manufacturing Date: 8-00 Ending Manufact...

Other Heat & Glo Models

All Heat & Glo Other