Heat & Glo 6000ARCH - Manual

Heat & Glo 6000ARCH

Heat & Glo 6000ARCH – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
29 Page 29
30 Page 30
31 Page 31
32 Page 32
33 Page 33
34 Page 34
35 Page 35
36 Page 36
37 Page 37
38 Page 38
39 Page 39
40 Page 40
41 Page 41
42 Page 42
43 Page 43
44 Page 44
45 Page 45
46 Page 46
47 Page 47
48 Page 48
Page: / 48

Table of Contents:

  • Page 2 – SAFETY AND WARNING INFORMATION
  • Page 3 – Section 5: Replacement Parts
  • Page 4 – Appliance Certification; Installers; CERTIFICATION; Installation Codes; Approvals
  • Page 5 – Introducing the
  • Page 6 – approval of such component part or accessory.; ANY SUCH ACTION MAY POSSIBLY CAUSE A FIRE HAZARD.; Where the unit is to be installed.
  • Page 7 – Figure 2. Diagram of the 6000ARCH
  • Page 8 – The diagram below shows space and clearance; Clearance Requirements; The top, back, and sides of the fireplace are defined
  • Page 9 – Framing the; CAUTION; MEASURE FIREPLACE DIMENSIONS, AND
  • Page 10 – Installing the; A. Vent System Approvals
  • Page 11 – Figure 6. D-Series Direct Vent Component Specifications
  • Page 12 – VERTICAL VENTING; A 12-inch length of straight vent; MUST; be the first vent
  • Page 13 – in better performance.; Figure 8. Corner Installation
  • Page 14 – Figure 9. Venting with One 90° Elbow
  • Page 16 – Figure 11. Venting with Two 90° Elbows
  • Page 18 – Figure 13. Venting with three 90° elbows
  • Page 19 – H + H; Figure 14. Venting with three 90° elbows; straight vent pipe; be the first
  • Page 20 – B. Installing Vent Components
  • Page 23 – REQUIRED; NOTE; Model DVK-01TRD does not need an exterior
  • Page 25 – Members
  • Page 28 – Figure 26. Vent Termination Minimum Clearances; IF EXTERIOR WALLS ARE FINISHED WITH
  • Page 29 – This also pertains to vertical vent systems installed
  • Page 30 – Figure 27. Minimum Height from Roof to Lowest
  • Page 31 – Standing Pilot Ignition; Securing the
  • Page 32 – The Gas
  • Page 33 – Figure 30. Gas Supply Line; Gas Pressure; Pressure
  • Page 34 – For Standing Pilot Ignition Wiring; This appliance; LABEL ALL WIRES PRIOR TO DISCONNECTION
  • Page 35 – Electrical wiring must be installed by a licensed
  • Page 36 – Finishing
  • Page 37 – IF JOINTS BETWEEN THE FINISHED WALLS AND; Ember Material; Hearth Extensions
  • Page 39 – Figure 38. Placement of the Ember Material; IT IS STRONGLY RECOMMENDED THAT TRIM; Glass Assembly
  • Page 40 – Before Lighting
  • Page 41 – LEAVE THIS INSTALLATION MANUAL; Heating Control; UP
  • Page 42 – IMPORTANT; TURN OFF THE GAS BEFORE SERVICING
  • Page 43 – Figure 41. Burner Flame Patterns
  • Page 44 – All parts listed in this; INSTALLERS GUIDE; may be; Standing Pilot with Robertshaw Controls only
  • Page 46 – DSI Valve; DSI Ignition Only; Both Standing Pilot and DSI Ignition
  • Page 47 – TEMPERED
  • Page 48 – Accessories
Loading the manual

1

- Do not store or use gasoline or other flam-

mable vapors and liquids in the vicinity of this

or any other appliance.

-

What to do if you smell gas

• Do not try to light any appliance.
• Do not touch any electrical switch.
• Do not use any phone in your building.
• Immediately call your gas supplier from a

neighbor's phone. Follow the gas supplier's

instructions.

• If you cannot reach your gas supplier, call

the fire department.

- Installation and service must be performed by a

qualified installer, service agency, or the gas

supplier.

Heat-N-Glo

Models:

6000TR

6000XLT-CDN

6000ARCH

6000XLS

Installers Guide

WARNING: IMPROPER INSTALLA-

TION, ADJUSTMENT, ALTERATION,

SERVICE OR MAINTENANCE CAN

CAUSE INJURY OR PROPERTY DAM-

AGE. REFER TO THIS MANUAL. FOR

ASSISTANCE OR ADDITIONAL INFOR-

MATION CONSULT A QUALIFIED IN-

STALLER, SERVICE AGENCY, OR THE

GAS SUPPLIER.

525-983C 1/00

READ THIS MANUAL BEFORE INSTALLING OR

OPERATING THIS APPLIANCE. THIS

INSTALL-

ERS GUIDE

MUST BE LEFT WITH THE APPLI-

ANCE FOR FUTURE REFERENCE.

1.

This appliance may be installed in an
aftermarket, permanently located,
manufactured (mobile) home, where not
prohibited by local codes.

2. This appliance is only for use with the

type of gas indicated on the rating plate.
This appliance is not convertible for use
with other gases, unless a certified kit is
used.

Please contact your Heat-N-Glo dealer for any

questions or concerns. For the number of your

nearest Heat-N-Glo dealer, please call 612-985-6000.

Printed in U.S.A. Copyright 2000,
Heat-N-Glo, a division of Hearth Technologies Inc.

20802 Kensington Boulevard, Lakeville, Mn 55044

WARNING: IF THE INFORMATION

IN THESE INSTRUCTIONS IS NOT

FOLLOWED EXACTLY, A FIRE OR

EXPLOSION MAY RESULT

CAUSING PROPERTY DAMAGE,

PERSONAL INJURY, OR DEATH.

Underwriters

Laboratories Listed

1

This product is covered by one or more of the following patents: (United States) 4,112,913; 4,408,594; 4,422,426; 4,424,792; 4,520,791; 4,793,322;

4,852,548; 4,875,464; 5,000,162; 5,016,609; 5,076,254 5,191,877; 5,218,953; 5,328,356; 5,429,495; 5,452,708; 5,542,407; 5,613,4 87; (Australia)

543790; 586383; (Canada) 1,123,296; 1,297,746; 2,195,264; (Mexico) 97-0457; (New Zealand) 200265; or other U.S. and foreign patents pending.

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - SAFETY AND WARNING INFORMATION

2 ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! SAFETY AND WARNING INFORMATION READ and UNDERSTAND all instructions carefully before starting the installation. FAILURE TO FOLLOW these installation instructions may result in a possible fire hazard and will void the warranty. Prior to the first firing of the fi...

Page 3 - Section 5: Replacement Parts

3 TABLE OF CONTENTS Safety and Warning Information ......................... 2 Section 1: Approvals and Codes ...................... 4 Approval Listings and Codes ................................... 4Appliance Certification ............................................. 4Installation Codes .............

Page 4 - Appliance Certification; Installers; CERTIFICATION; Installation Codes; Approvals

4 Approval Listings and Codes Appliance Certification The Heat-N-Glo models discussed in this Installers Guide have been tested to certification standards and listed by the applicable laboratories. CERTIFICATION MODEL LABORATORY TYPE STANDARD 6000TR & Underwriters Vented Gas ANSI Z21.50• CGA2.22...

Other Heat & Glo Models

All Heat & Glo Other