Page 2 - Congratulations; Listing Label Information/Location; Owner’s Manual; Read this manual before installing or operating this appliance.; We recommend that you record the following; Homeowner Reference Information; NATURAL; XXXXXXXX
Heat & Glo • SL-550 / 750 / 950TV-D • 2053-985 Rev. J • 4/07 2 Congratulations Listing Label Information/Location Model Name: ___________________________________________ Date purchased/installed: __________________ Serial Number: __________________________________________ Location on appliance: ...
Page 3 - Table of Contents
3 Heat & Glo • SL-550 / 750 / 950TV-D • 2053-985 Rev. J • 4/07 - Table of Contents - Section 1: Listing and Code Approvals A. Appliance Certifi cation ................................... 4 B. Glass Specifi cations ...................................... 4 C. BTU Specifi cations .....................
Page 4 - B. Glass Specifi cations; ANSI; Appliance Certifi cation; This installation must conform with local codes. In the; National; and the; CAN/CGA B149 Installation Codes; Listing and Code Approvals; C. BTU Specifi cations; , and local Building Offi cials for the
Heat & Glo • SL-550 / 750 / 950TV-D • 2053-985 Rev. J • 4/07 4 B. Glass Specifi cations Hearth & Home Technologies appliances manufactured with tempered glass may be installed in hazardous locations such as bathtub enclosures as defi ned by the Consumer Product Safety Commission (CPSC). The ...
Page 5 - shall be considered; F. Combustible Materials Specifi cation; WARNING
5 Heat & Glo • SL-550 / 750 / 950TV-D • 2053-985 Rev. J • 4/07 D. High Altitude Installations U.L. Listed gas appliances are tested and approved without requiring changes for elevations from 0 to 2000 feet in the U.S.A. and Canada. When installing this appliance at an elevation above 2000 feet, ...
Page 6 - A. Design and Installation Considerations; Getting Started; Where the appliance is to be installed.; See Sections 3; The vent system confi guration to be used.; See Sections; Framing and fi nishing details.; Check building codes prior to installation.; CAUTION
Heat & Glo • SL-550 / 750 / 950TV-D • 2053-985 Rev. J • 4/07 6 A. Design and Installation Considerations Heat & Glo B-type vent gas appliances are designed to operate with all exhaust gases expelled to the outside of the building, and combustion air pulled from the room. Getting Started 2 Wh...
Page 7 - B. Negative Pressure; Negative pressure
7 Heat & Glo • SL-550 / 750 / 950TV-D • 2053-985 Rev. J • 4/07 Recommended Location Marginal Location Location Not Recommended Recommended Location Location NOT Recommended Multi-level Roofs Windward Leeward Figure 2.1 B. Negative Pressure Draft is the pressure difference needed to vent fi repla...
Page 8 - Any such action may cause a fi re hazard.
Heat & Glo • SL-550 / 750 / 950TV-D • 2053-985 Rev. J • 4/07 8 D. Inspect Appliance and Components C. Tools and Supplies Needed Before beginning the installation be sure that the following tools and building supplies are available. Reciprocating saw Framing material Pliers Hi temp caulking mater...
Page 9 - Framing and Clearances; Illustrations refl ect typical installations and are FOR; A. Selecting Appliance Location; Model; • Vent Clearances and Framing
9 Heat & Glo • SL-550 / 750 / 950TV-D • 2053-985 Rev. J • 4/07 3 Framing and Clearances NOTE: • Illustrations refl ect typical installations and are FOR DESIGN PURPOSES ONLY. • I llustrations/diagrams are not drawn to scale. • Actual installation may vary due to individual design preference. Fir...
Page 10 - B. Constructing the Appliance Chase; MUST; be; Models
Heat & Glo • SL-550 / 750 / 950TV-D • 2053-985 Rev. J • 4/07 10 C. Clearances Figure 3.2 Clearances to Combustibles C B D A Fire Risk. • Construct chase to all clearance specifi cations in manual. • Locate and install appliance to all clearance specifi cations in manual Fire Risk. Odor Risk. • I...
Page 11 - D. Mantel Projections
11 Heat & Glo • SL-550 / 750 / 950TV-D • 2053-985 Rev. J • 4/07 D. Mantel Projections Figure 3.3 Clearances to Mantels or other Combustibles above Appliance 1/2 INCH (13mm) 12 INCHES (305mm) TOP FRONT EDGEOF FIREPLACE 12 INCHES (305mm) NON-COMBUSTIBLE MATERIAL ONLY
Page 12 - A. Vent Termination Minimum Clearances; • Do not pack air space with insulation or; Termination Locations
Heat & Glo • SL-550 / 750 / 950TV-D • 2053-985 Rev. J • 4/07 12 A. Vent Termination Minimum Clearances Fire Risk. Explosion Risk. Maintain vent clearance to combustibles as specifi ed. • Do not pack air space with insulation or other materials. Failure to keep insulation or other materials away ...
Page 13 - B. Vent System Confi guration
13 Heat & Glo • SL-550 / 750 / 950TV-D • 2053-985 Rev. J • 4/07 5 Vent Information and Diagrams Fire Hazard. Explosion Risk. Asphyxiation Risk.Do NOT connect this gas appliance to a chimney fl ue serving a separate solid-fuel or gas burning appliance. • Vent this appliance directly outside. • Us...
Page 15 - A. Pipe Clearances to Combustibles; Vent Clearances and Framing; • Do not pack air space with insulation or other; C. Vertical Penetration Framing; Fire Hazard
15 Heat & Glo • SL-550 / 750 / 950TV-D • 2053-985 Rev. J • 4/07 A. Pipe Clearances to Combustibles Vent Clearances and Framing 6 Fire Risk. Explosion Risk. Maintain vent clearance to combustibles as specifi ed. • Do not pack air space with insulation or other materials. • National building codes...
Page 16 - A. Installing Outside Air Kit Damper Assembly; Appliance Preparation; Sharp Edges; HANDLE; B. Gas and Electrical Connections
Heat & Glo • SL-550 / 750 / 950TV-D • 2053-985 Rev. J • 4/07 16 A. Installing Outside Air Kit Damper Assembly Appliance Preparation 7 CAUTION Sharp Edges • Wear protective gloves and safety glasses dur-ing installation. Asphyxiation Risk. Fire Risk. Do NOT draw outside combustion air from: • Wal...
Page 17 - C. Securing and Leveling Appliance
17 Heat & Glo • SL-550 / 750 / 950TV-D • 2053-985 Rev. J • 4/07 C. Securing and Leveling Appliance The diagram shows how to properly position, level, and secure the appliance (see Figure 7.3). Nailing tabs are pro-vided to secure the appliance to the framing members. • Place the appliance into p...
Page 18 - A. Assembly of Vent Sections; Installing Vent Pipe; Fire Risk; B. Attaching Vent to Firebox; Combustion Fume Risk.; C. Securing Vent Sections
Heat & Glo • SL-550 / 750 / 950TV-D • 2053-985 Rev. J • 4/07 18 A. Assembly of Vent Sections This B-Vent appliance requires 5-inch (SL-550/750TV-D) or 6-inch (SL-950TV-D) B-vent double-wall pipe. Follow the pipe manufacturer’s installation guidelines when installing the unit. This will ensure pr...
Page 19 - Gas Information; • If substituting for these components, please consult; The gap between the supply piping and gas access; Refer to Reference; Pressure; Manifold Pressure
19 Heat & Glo • SL-550 / 750 / 950TV-D • 2053-985 Rev. J • 4/07 NOTE: Have the gas supply line installed in accordance w i t h l o c a l b u i l d i n g c o d e s , i f a n y. I f n o t , f o l l o w A N S I 223.1. Installation should be done by a qualifi ed installer approved and/or licensed as...
Page 20 - HIGH ALTITUDE INSTALLATIONS; • Ensure that gas line does not come in contact with outer; • Check all fi ttings and connections.; • A small amount of air will be in the gas supply lines.
Heat & Glo • SL-550 / 750 / 950TV-D • 2053-985 Rev. J • 4/07 20 Fire or Explosion Hazard • Gas build-up during line purge may ignite. • Purge should be performed by qualifi ed technician. • Ensure adequate ventilation. • Ensure there are no ignition sources such as sparks or open fl ames. Fire h...
Page 21 - A. Recommendation for Wire; Electrical Information; This appliance must be electrically wired and grounded; National Electric Code ANSI/NFPA 70-latest; or the; C. Intellifi re Ignition System Wiring; and may cause explosion.; Battery polarity must be correct or module damage will occur.; Optional Accessories Requirements
21 Heat & Glo • SL-550 / 750 / 950TV-D • 2053-985 Rev. J • 4/07 A. Recommendation for Wire This appliance requires 110-120 VAC be wired to the junction box either for use of optional accessories (stand-ing pilot ignition) or for proper operation of the appliance (Intellifi re ignition). Refer to...
Page 22 - D. Standing Pilot Ignition System Wiring
Heat & Glo • SL-550 / 750 / 950TV-D • 2053-985 Rev. J • 4/07 22 D. Standing Pilot Ignition System Wiring This standing pilot ignition system wiring does not require a 110 VAC supply to operate. Figure 10.3 Standing Pilot Ignition Wiring Diagram Figure 10.2 Intellifi re Pilot Ignition (IPI) Wirin...
Page 23 - Do NOT wire; E. Junction Box Installation; OUTSIDE
23 Heat & Glo • SL-550 / 750 / 950TV-D • 2053-985 Rev. J • 4/07 WHT WHT BLK BLK GRN wireinside box Copperground attachedto GRN screw withGRN wire 14/2WG Cover Plateoutside firebox RomexConnector F. Wall Switch Installation for Fan (Optional) Figure 10.4 Junction Box Detail Figure 10.5 Fan Contro...
Page 24 - A. Mantel Projections; Finishing
Heat & Glo • SL-550 / 750 / 950TV-D • 2053-985 Rev. J • 4/07 24 A. Mantel Projections Figure 11.1 shows the minimum vertical and corresponding maximum horizontal dimensions of appliance mantels or other combustible projections above the top front edge of the appliance. Finishing B. Facing Materi...
Page 25 - Appliance Setup; A. Remove Shipping Materials; Placing the Ember Material; C. Clean the Appliance
25 Heat & Glo • SL-550 / 750 / 950TV-D • 2053-985 Rev. J • 4/07 Appliance Setup 12 A. Remove Shipping Materials Remove shipping materials from inside or underneath the fi rebox. B. Remove Grate Shipping Support • Remove the log pack and hood, if applicable. • Bend top retaining tab of grate ship...
Page 26 - G. Positioning the Logs; Carefully remove the logs from the packaging.; TABS; Slide the right edge of log #2 forward until it touches the grate.; NOTCH
Heat & Glo • SL-550 / 750 / 950TV-D • 2053-985 Rev. J • 4/07 26 Log Set Assembly: LOGS-SL550-D G. Positioning the Logs If the gas logs have been factory installed they should not need to be positioned. If the logs have been packaged separately, refer to the following instructions. Carefully remo...
Page 27 - Slide the left edge of log #3 forward until it touches the grate.
27 Heat & Glo • SL-550 / 750 / 950TV-D • 2053-985 Rev. J • 4/07 LOG #3 (SRV2044-703): Place log #3 on the left two grate bars using the notch on the bottom of log #3. Slide the left edge of log #3 forward until it touches the grate. LOG #4 (SRV2044-701): Place log #4 into the tab on log #1. The ...
Page 30 - Removing Glass Assembly; Handle glass doors with care.; TAB LOCATOR; Full open
Heat & Glo • SL-550 / 750 / 950TV-D • 2053-985 Rev. J • 4/07 30 Figure 12.17 Glass Assembly H. Glass Assembly Removing Glass Assembly Pull the four glass assembly latches out of the groove on the glass frame. Remove glass door from the appliance (see Figure 12.17). Replacing Glass Assembly Repla...
Page 31 - A. Before Lighting Appliance; B. Check Appliance Draft
31 Heat & Glo • SL-550 / 750 / 950TV-D • 2053-985 Rev. J • 4/07 A. Before Lighting Appliance Before lighting this appliance determine if it has a Standing Pilot or Intellifi re ignition system by opening the control access panel to view wiring system and gas valve. If this appliance has a red or...
Page 32 - C. Lighting Appliance; Intellifi re Ignition; Final Inspection by; NOT FOR USE; WHAT TO DO IF YOU SMELL GAS
Heat & Glo • SL-550 / 750 / 950TV-D • 2053-985 Rev. J • 4/07 32 C. Lighting Appliance Intellifi re Ignition Final Inspection by _____________________________ 1. Turn off all electric power to the appli- ance. 2. This appliance is equipped with an igni- tion device which automatically lights the ...
Page 33 - Standing Pilot Ignition; B E F O R E L I G H T I N G ,
33 Heat & Glo • SL-550 / 750 / 950TV-D • 2053-985 Rev. J • 4/07 1. Turn off all electric power to the appliance if service is to be performed. 2. Open control access panel. 3. Move switch to “OFF” position. 4. Push in gas control knob slightly and turn clock- wise to OFF”. Do not force. 5. Close...
Page 34 - D. After Appliance is Lit; Initial Break-in Procedure; E. Frequently Asked Questions; Keep combustible household items away from appliance.; ISSUE
Heat & Glo • SL-550 / 750 / 950TV-D • 2053-985 Rev. J • 4/07 34 D. After Appliance is Lit Initial Break-in Procedure When you light the appliance, you may notice that it pro-duces heat which does have an associated odor or smell. If you feel this odor is excessive it may require the initial thre...
Page 35 - Troubleshooting; Symptom; After repeated; A. Standing Pilot Ignition System
35 Heat & Glo • SL-550 / 750 / 950TV-D • 2053-985 Rev. J • 4/07 Troubleshooting 14 Symptom Possible Causes Corrective Actions 1. After repeated triggering of the red or black piezo ignitor button, the spark ignitor will not light the pilot. a. Defective ignitor. Check the spark at the electrode ...
Page 37 - B. Intellifi re Ignition System; Pilot won’t
37 Heat & Glo • SL-550 / 750 / 950TV-D • 2053-985 Rev. J • 4/07 B. Intellifi re Ignition System Symptom Possible Causes Corrective Actions 1. The ignitor/ module makes noise, but no spark. a. Incorrect wir-ing. Verify “S” wire (white) for sensor and “I” wire (orange) for ignitor are con-nected t...
Page 38 - Pilot will not light.
Heat & Glo • SL-550 / 750 / 950TV-D • 2053-985 Rev. J • 4/07 38 Intellifi re Ignition System - (continued) Symptom Possible Causes Corrective Actions 3. ...continued d. Damaged pilot assembly or dirty sensor rod. Verify that ceramic insulator around the sensor rod is not cracked, dam-aged, or lo...
Page 39 - Maintaining and Servicing Appliance; Clean glass after initial 3-4 hours; L o n g e r o p e r a t i o n w i t h o u t; When cleaning glass door:
39 Heat & Glo • SL-550 / 750 / 950TV-D • 2053-985 Rev. J • 4/07 Maintaining and Servicing Appliance 15 Although the frequency of appliance servicing and maintenance will depend on use and the type of installation, a qualifi ed service technician should perform an appliance check-up at the beginn...
Page 41 - Reference Materials; Appliance Dimensions Table; A. Appliance Dimension Diagram; Section 3
41 Heat & Glo • SL-550 / 750 / 950TV-D • 2053-985 Rev. J • 4/07 Reference Materials 16 Appliance Dimensions Table A. Appliance Dimension Diagram Dimensions are actual appliance dimensions. Use for reference only. For framing dimensions and clearances refer to Section 3 . Figure 16.1 Appliance Di...
Page 42 - Part number list on following page.; Log Set Assembly; Service Parts Diagram
Heat & Glo • SL-550 / 750 / 950TV-D • 2053-985 Rev. J • 4/07 42 1 2 3 4 5 B. Service Parts Part number list on following page. Log Set Assembly Service Parts Diagram Beginning Manufacturing Date: 1-06 Ending Manufacturing Date: ______ SL-550TV-D 6 7 8 9 10 11 12 13 14
Page 43 - B. Service Parts List
43 Heat & Glo • SL-550 / 750 / 950TV-D • 2053-985 Rev. J • 4/07 IMPORTANT: THIS IS DATED INFORMATION. The most current information is located on your dealers’ VIP site. When ordering, supply serial and model numbers to ensure correct service parts. AVAILABLE TO SHIP IN 24 HOURS ITEM DESCRIPTION ...
Page 45 - Service Parts; og Set Assembly
45 Heat & Glo • SL-550 / 750 / 950TV-D • 2053-985 Rev. J • 4/07 1 2 3 4 5 6 Service Parts Part number list on following page. Service Parts Diagram SL-750TV-D L og Set Assembly 7 8 9 10 11 12 13 14 15 Beginning Manufacturing Date: 1-06 Ending Manufacturing Date: ______
Page 46 - Service Parts List
Heat & Glo • SL-550 / 750 / 950TV-D • 2053-985 Rev. J • 4/07 46 Service Parts List SL-750TV-D IMPORTANT: THIS IS DATED INFORMATION. The most current information is lo-cated on your dealers’ VIP site. When ordering, supply serial and model numbers to ensure correct service parts. AVAILABLE TO SHI...
Page 51 - Valve Assembly Parts List; Standing Pilot
51 Heat & Glo • SL-550 / 750 / 950TV-D • 2053-985 Rev. J • 4/07 Valve Assembly Parts List Service Parts SL-550 / 750 / 950TV-D Standing Pilot Valve Assembly 1 2 3 4 5 6 7 8 10 11 12 13 14 IMPORTANT: THIS IS DATED INFORMATION. The most current information is located on your dealers’ VIP site. Whe...
Page 52 - IPI Valve Assembly; AVAILABLE; ITEM
Heat & Glo • SL-550 / 750 / 950TV-D • 2053-985 Rev. J • 4/07 52 Valve Assembly Parts List Service Parts SL-550 / 750 / 950TV-D-IPI IPI Valve Assembly 1 2 3 4 5 6 7 8 10 11 12 13 14 IMPORTANT: THIS IS DATED INFORMATION. The most current information is located on your dealers’ VIP site. When order...
Page 53 - C. Limited Lifetime Warranty; LIMITED LIFETIME WARRANTY; servicing by an authorized HEAT & GLO dealer.
53 Heat & Glo • SL-550 / 750 / 950TV-D • 2053-985 Rev. J • 4/07 C. Limited Lifetime Warranty © 2005 Hearth & Home Technologies Inc. LIMITED LIFETIME WARRANTY HEAT & GLO GAS APPLIANCE PRODUCTS 060-981D 3/05 BASIC ONE-YEAR WARRANTY. HEAT & GLO, a brand of HEARTH & HOME TECHNOLOGIES...
Page 54 - D. Contact Information; For the location of your nearest Heat & Glo dealer,; DO NOT DISCARD THIS MANUAL; • Leave this manual with
Heat & Glo • SL-550 / 750 / 950TV-D • 2053-985 Rev. J • 4/07 54 Heat & Glo, a brand of Hearth & Home Technologies Inc. 20802 Kensington Boulevard, Lakeville, MN 55044 www.heatnglo.com - NOTES - ________________________________________________________________________________ _____________...