Heat & Glo 6000CL-IPI-S - Manuals
Heat & Glo 6000CL-IPI-S – Manual in PDF format online.
Manuals:
Manual Heat & Glo 6000CL-IPI-S
Summary
Heat & Glo • 6000CL-IPI-S, 6000CL-IPI-T, 8000CL-IPI-S 8000CL-IPI-T • 2165-900 Rev. S • 9/12 2 Listing Label Information/Location Model Name: ___________________________________________ Date purchased/installed: __________________ Serial Number: __________________________________________ Location...
3 Heat & Glo • 6000CL-IPI-S, 6000CL-IPI-T, 8000CL-IPI-S 8000CL-IPI-T • 2165-900 Rev. S • 9/12 Safety Alert Key: • DANGER! Indicates a hazardous situation which, if not avoided will result in death or serious injury.• WARNING! Indicates a hazardous situation which, if not avoided could result in ...
Heat & Glo • 6000CL-IPI-S, 6000CL-IPI-T, 8000CL-IPI-S 8000CL-IPI-T • 2165-900 Rev. S • 9/12 4 = Contains updated information. 13 Finishing A. Mantel and Wall Projections . . . . . . . . . . . . . . . . . . . . . . . 53B. Facing Material . . . . . . . . . . . . . . . . . . . . . . . . . . . . ....
Heat & Glo • 6000CL-IPI-S, 6000CL-IPI-T, 8000CL-IPI-S 8000CL-IPI-T • 2165-900 Rev. S • 9/12 6 4021-645C 12-29-10 Page 2 of 2 WARRANTY CONDITIONS: • This warranty only covers HHT appliances that are purchased through an HHT authorized dealer or distributor. A list of HHT authorized dealers is ava...
7 Heat & Glo • 6000CL-IPI-S, 6000CL-IPI-T, 8000CL-IPI-S 8000CL-IPI-T • 2165-900 Rev. S • 9/12 C. BTU Specifications MODELS: 6000CL-IPI, 6000CL-IPILP, 8000CL-IPI, 8000CL-IPILP LABORATORY: Underwriters Laboratories, Inc. (UL) TYPE: Direct Vent Gas Appliance Heater STANDARD: ANSI Z21.88b-2008 • CSA...
Heat & Glo • 6000CL-IPI-S, 6000CL-IPI-T, 8000CL-IPI-S 8000CL-IPI-T • 2165-900 Rev. S • 9/12 8 H. Requirements for the Commonwealth of Massachusetts For all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used in whole or in part for residenti...
9 Heat & Glo • 6000CL-IPI-S, 6000CL-IPI-T, 8000CL-IPI-S 8000CL-IPI-T • 2165-900 Rev. S • 9/12 Figure 2.1 General Operating Parts B. Your Fireplace WARNING! DO NOT operate fireplace before read - ing and understanding operating instructions. Failure to operate fireplace according to operating ins...
Heat & Glo • 6000CL-IPI-S, 6000CL-IPI-T, 8000CL-IPI-S 8000CL-IPI-T • 2165-900 Rev. S • 9/12 10 D. Clear Space WARNING! DO NOT place combustible objects in front of the fireplace or block louvers. High temperatures may start a fire. See Figure 2.2. Avoid placing candles and other heat-sensitive o...
11 Heat & Glo • 6000CL-IPI-S, 6000CL-IPI-T, 8000CL-IPI-S 8000CL-IPI-T • 2165-900 Rev. S • 9/12 J. Before Lighting Fireplace Before operating this fireplace for the first time, have a qualified service technician : • Verify all shipping materials have been removed from inside and/or underneath th...
Heat & Glo • 6000CL-IPI-S, 6000CL-IPI-T, 8000CL-IPI-S 8000CL-IPI-T • 2165-900 Rev. S • 9/12 12 K. Lighting Instructions (IPI) 1. This appliance is equipped with an ignition device which automatically lights the burner. DO NOT try to light the burner by hand. 2. Wait five (5) minutes to clear out...
13 Heat & Glo • 6000CL-IPI-S, 6000CL-IPI-T, 8000CL-IPI-S 8000CL-IPI-T • 2165-900 Rev. S • 9/12 Initial Break-in Procedure• The fireplace should be run three to four hours continuously on high. • Turn the fireplace off and allow it to completely cool.• Remove fixed glass assembly. See Section 14....
Heat & Glo • 6000CL-IPI-S, 6000CL-IPI-T, 8000CL-IPI-S 8000CL-IPI-T • 2165-900 Rev. S • 9/12 14 Glass Cleaning Frequency: Seasonally By: Homeowner Tools Needed : Protective gloves, glass cleaner, drop cloth and a stable work surface. CAUTION! Handle fixed glass assembly with care. Glass is breaka...
15 Heat & Glo • 6000CL-IPI-S, 6000CL-IPI-T, 8000CL-IPI-S 8000CL-IPI-T • 2165-900 Rev. S • 9/12 B. Maintenance Tasks-Qualified Service Technician The following tasks must be performed by a qualified ser- vice technician. Gasket Seal and Glass Assembly Inspection Frequency: Annually By: Qualified ...
Heat & Glo • 6000CL-IPI-S, 6000CL-IPI-T, 8000CL-IPI-S 8000CL-IPI-T • 2165-900 Rev. S • 9/12 16 Figure 3.3 Side Refractory Removal C. Refractory, Grate and Valve Assembly Removal It may become necessary to remove the refractory, grate and valve assemblies. This task should be performed by a quali...
17 Heat & Glo • 6000CL-IPI-S, 6000CL-IPI-T, 8000CL-IPI-S 8000CL-IPI-T • 2165-900 Rev. S • 9/12 BASE REFRACTORY Figure 3.6 Valve Assembly Removal Note: The base refractory must be removed to access screws. Figure 3.5 Base Refractory Removal D. Burner Identification/Verification The burner may be ...
Heat & Glo • 6000CL-IPI-S, 6000CL-IPI-T, 8000CL-IPI-S 8000CL-IPI-T • 2165-900 Rev. S • 9/12 18 A. Typical Appliance System NOTICE: Illustrations and photos reflect typical installations and are for design purposes only. Illustrations/diagrams are not drawn to scale. Actual product may vary from ...
19 Heat & Glo • 6000CL-IPI-S, 6000CL-IPI-T, 8000CL-IPI-S 8000CL-IPI-T • 2165-900 Rev. S • 9/12 B. Design and Installation Considerations Heat & Glo direct vent gas appliances are designed to operate with all combustion air siphoned from outside of the building and all exhaust gases expelled ...
Heat & Glo • 6000CL-IPI-S, 6000CL-IPI-T, 8000CL-IPI-S 8000CL-IPI-T • 2165-900 Rev. S • 9/12 20 5 Framing and Clearances A. Selecting Appliance Location When selecting a location for the appliance it is important to consider the required clearances to walls (see Figure 5.1). WARNING! Risk of Fire...
21 Heat & Glo • 6000CL-IPI-S, 6000CL-IPI-T, 8000CL-IPI-S 8000CL-IPI-T • 2165-900 Rev. S • 9/12 B. Constructing the Appliance Chase A chase is a vertical box-like structure built to enclose the gas appliance and/or its vent system. In cooler climates the vent should be enclosed inside the chase. ...
Heat & Glo • 6000CL-IPI-S, 6000CL-IPI-T, 8000CL-IPI-S 8000CL-IPI-T • 2165-900 Rev. S • 9/12 22 D. Mantel and Wall Projections WARNING! Risk of Fire! Comply with all minimum clear- ances as specified. Framing or finishing material closer than the minimums listed must be constructed entirely of no...
23 Heat & Glo • 6000CL-IPI-S, 6000CL-IPI-T, 8000CL-IPI-S 8000CL-IPI-T • 2165-900 Rev. S • 9/12 A. Vent Termination Minimum Clearances Roof Pitch H (Min.) Ft. Flat to 6/12...........................................................1.0* Over 6/12 to 7/12 ...............................................
Heat & Glo • 6000CL-IPI-S, 6000CL-IPI-T, 8000CL-IPI-S 8000CL-IPI-T • 2165-900 Rev. S • 9/12 24 Figure 6.3 Minimum Clearances for Termination O N P R Q X = AIR SUPPLY INLET A = 12 inches.................clearances above grade, veranda, porch, deck or balcony B = 12 inches.................clearanc...
25 Heat & Glo • 6000CL-IPI-S, 6000CL-IPI-T, 8000CL-IPI-S 8000CL-IPI-T • 2165-900 Rev. S • 9/12 A. Approved Pipe This appliance is approved for use with Hearth & Home Technologies DVP or SLP venting systems. Refer to Sec- tion 16B for vent component information. DO NOT mix pipe, fittings or j...
27 Heat & Glo • 6000CL-IPI-S, 6000CL-IPI-T, 8000CL-IPI-S 8000CL-IPI-T • 2165-900 Rev. S • 9/12 INSTALLED HORIZONTALLY H 1 H 2 V 1 Figure 7.4 Two Elbows Note: For corner installations: A 6 inch (152 mm) section of straight pipe may need to be attached to the appliance before a 90º elbow, to allow...
Heat & Glo • 6000CL-IPI-S, 6000CL-IPI-T, 8000CL-IPI-S 8000CL-IPI-T • 2165-900 Rev. S • 9/12 28 Figure 7.5 Top Vent - Horizontal Termination - (continued) Three Elbows H 2 H 1 V 2 V 1 V 1 Min. H 1 Max. V 2 Min. H 2 Max. Elbow only 2 ft. 610 mm 0 in. 0 mm 1 ft. 305 mm 6 in. 152 mm 3 ft 914 mm 6 in...
29 Heat & Glo • 6000CL-IPI-S, 6000CL-IPI-T, 8000CL-IPI-S 8000CL-IPI-T • 2165-900 Rev. S • 9/12 FLUE RESTRICTOR TOP REFRACTORY Top Vent - Vertical Termination No Elbow Figure 7.6 Note: If installing a vertical vent/ termination off the top of the appli- ance, the flue restrictor should be used. S...
Heat & Glo • 6000CL-IPI-S, 6000CL-IPI-T, 8000CL-IPI-S 8000CL-IPI-T • 2165-900 Rev. S • 9/12 30 H 1 V 1 V 2 Top Vent - Vertical Termination (continued) Figure 7.11 Two Elbows Figure 7.10 4. Center the Flue Restrictor on vent and secure in place by using two self-tapping screws (see Figure 7.10). ...
31 Heat & Glo • 6000CL-IPI-S, 6000CL-IPI-T, 8000CL-IPI-S 8000CL-IPI-T • 2165-900 Rev. S • 9/12 Figure 7.12 Top Vent - Vertical Termination - (continued) Three Elbows INSTALLED HORIZONTALLY H 1 H 2 V 1 V 2 V 1 H 1 + H 2 V 2 V 1 + V 2 Minimum H 1 + H 2 Maximum Elbow only 1 ft. 305 mm * * * 1 ft. 3...
Heat & Glo • 6000CL-IPI-S, 6000CL-IPI-T, 8000CL-IPI-S 8000CL-IPI-T • 2165-900 Rev. S • 9/12 32 Rear Vent - Horizontal Termination Figure 7.14 No Elbow One 45º Elbow H 1 H 1 = 16 in. (406 mm) Maximum Do not use a 45º elbow in corner installations. Use two 90º elbows instead. Figure 7.13 H 1
33 Heat & Glo • 6000CL-IPI-S, 6000CL-IPI-T, 8000CL-IPI-S 8000CL-IPI-T • 2165-900 Rev. S • 9/12 Rear Vent - Horizontal Termination - (continued) Two Elbows Figure 7.15 H 1 Maximum V 1 Minimum H 2 H 1 + H 2 Maximum 1 ft. 305 mm Back to Back 90º Elbows 1 ft. 305 mm 2 ft. 610 mm 2 ft. 610 mm 6 in. 1...
35 Heat & Glo • 6000CL-IPI-S, 6000CL-IPI-T, 8000CL-IPI-S 8000CL-IPI-T • 2165-900 Rev. S • 9/12 Rear Vent - Vertical Termination One Elbow Figure 7.17 Two Elbows Figure 7.18 V 1 Minimum H 1 Maximum 6 in. 152 mm 2 ft. 610 mm 1 ft. 305 mm 3 ft. 914 mm 2 ft. 610 mm 5 ft. 1.5 m 3 ft. 914 mm 7 ft. 2.1...
Heat & Glo • 6000CL-IPI-S, 6000CL-IPI-T, 8000CL-IPI-S 8000CL-IPI-T • 2165-900 Rev. S • 9/12 36 Rear Vent - Vertical Termination - (continued) Three Elbows Figure 7.19 Three Elbows Figure 7.20 H 1 H 2 H 3 V 1 Minimum H 1 + H 2 + H 3 Maximum * * * 8 ft. 2.4 m 6 ft. 1.8 m * * * 9 ft. 2.7 m 7 ft. 2....
37 Heat & Glo • 6000CL-IPI-S, 6000CL-IPI-T, 8000CL-IPI-S 8000CL-IPI-T • 2165-900 Rev. S • 9/12 A* B* 10 in. 12 in. C D 10 in. 12 in. A. Pipe Clearances to Combustibles WARNING! Risk of Fire! Maintain air space clearance to vent. DO NOT pack insulation or other combustibles: • Between ceiling fir...
Heat & Glo • 6000CL-IPI-S, 6000CL-IPI-T, 8000CL-IPI-S 8000CL-IPI-T • 2165-900 Rev. S • 9/12 38 C. Install the Ceiling Firestop A ceiling firestop MUST be used between floors and attics.• DVP pipe only - Frame an opening 10 in. by 10 in. (254 mm by 254 mm) whenever the vent penetrates a ceiling/f...
39 Heat & Glo • 6000CL-IPI-S, 6000CL-IPI-T, 8000CL-IPI-S 8000CL-IPI-T • 2165-900 Rev. S • 9/12 D. Install Attic Insulation Shield WARNING! Fire Risk. DO NOT allow loose materials or insulation to touch vent. Hearth & Home Technologies Inc. requires the use of an attic shield. The National Fu...
Heat & Glo • 6000CL-IPI-S, 6000CL-IPI-T, 8000CL-IPI-S 8000CL-IPI-T • 2165-900 Rev. S • 9/12 40 9 Appliance Preparation CAUTION! Risk of Cuts, Abrasions or Flying Debris. Wear protective gloves and safety glasses during instal- lation. Sheet metal edges are sharp.NOTICE: Once appliance is set up ...
Heat & Glo • 6000CL-IPI-S, 6000CL-IPI-T, 8000CL-IPI-S 8000CL-IPI-T • 2165-900 Rev. S • 9/12 42 Figure 9.14 Proper Positioning and Securing of an Appliance NAILING TABS (BOTH SIDES) PILOT HOLES Figure 9.12 Non-combustible Board C. Installing the Non-combustible Board The factory supplied non-comb...
43 Heat & Glo • 6000CL-IPI-S, 6000CL-IPI-T, 8000CL-IPI-S 8000CL-IPI-T • 2165-900 Rev. S • 9/12 10 Installing Vent Pipe (DVP and SLP Pipe) A. Assemble Vent Sections (DVP Pipe Only) Attach Vent to the Firebox Assembly Note: The end of the pipe sections with the lanced tabs will face toward the app...
Heat & Glo • 6000CL-IPI-S, 6000CL-IPI-T, 8000CL-IPI-S 8000CL-IPI-T • 2165-900 Rev. S • 9/12 44 B. Assemble Vent Sections (SLP Pipe Only) To attach the first vent component to the starting collars of the appliance:• Attach a DVP-2SL or DVP-SLP24 adapter to the starting collar of the appliance. • ...
45 Heat & Glo • 6000CL-IPI-S, 6000CL-IPI-T, 8000CL-IPI-S 8000CL-IPI-T • 2165-900 Rev. S • 9/12 120º Figure 10.8 Securing Vertical Pipe Sections 120º Figure 10.9 Securing Horizontal Pipe Sections E. Disassemble Vent Sections • Rotate either section (see Figure 10.10) so the seams on both pipe sec...
Heat & Glo • 6000CL-IPI-S, 6000CL-IPI-T, 8000CL-IPI-S 8000CL-IPI-T • 2165-900 Rev. S • 9/12 46 F. Install Decorative Ceiling Components (SLP only) A decorative ceiling thimble can be installed on a flat ceil- ing through which the vent passes. The decorative ceiling thimble is used to cover the ...
47 Heat & Glo • 6000CL-IPI-S, 6000CL-IPI-T, 8000CL-IPI-S 8000CL-IPI-T • 2165-900 Rev. S • 9/12 G. Install Metal Roof Flashing • See minimum vent heights for various pitched roofs (Figure 10.14) to determine the length of pipe to extend through the roof. • Slide the roof flashing over the pipe se...
Heat & Glo • 6000CL-IPI-S, 6000CL-IPI-T, 8000CL-IPI-S 8000CL-IPI-T • 2165-900 Rev. S • 9/12 48 SCREWS CAULK STORM COLLAR (1 of 3) Figure 10.18 TERMINATION CAP I. Install Vertical Termination Cap • Attach the vertical termination cap by sliding the inner collar of the cap into the inner flue of t...
49 Heat & Glo • 6000CL-IPI-S, 6000CL-IPI-T, 8000CL-IPI-S 8000CL-IPI-T • 2165-900 Rev. S • 9/12 Figure 10.20 Venting through the wall INTERIOR HEAT SHIELD OR EXTENDED HEAT SHIELD WALL SHIELD FIRESTOP HEAT SHIELD 1-1/2 IN. (38 MM) MIN. OVERLAP SHEATHING VENT DEPTH FROM BACK OF APPLIANCE TO OUTSIDE...
Heat & Glo • 6000CL-IPI-S, 6000CL-IPI-T, 8000CL-IPI-S 8000CL-IPI-T • 2165-900 Rev. S • 9/12 50 A. Fuel Conversion • Make sure the appliance is compatible with available gas types. • Conversions must be made by a qualified service technician using Hearth & Home Technologies specified and appr...
51 Heat & Glo • 6000CL-IPI-S, 6000CL-IPI-T, 8000CL-IPI-S 8000CL-IPI-T • 2165-900 Rev. S • 9/12 A. Wiring Requirements NOTICE: This appliance must be electrically wired and grounded in accordance with local codes or, in the absence of local codes, with National Electric Code ANSI/NFPA 70-latest e...
Heat & Glo • 6000CL-IPI-S, 6000CL-IPI-T, 8000CL-IPI-S 8000CL-IPI-T • 2165-900 Rev. S • 9/12 52 F. Wall Switch Installation for Fan (Optional) If the box is being wired to a wall mounted switch for use with a fan (See Figure 12.3):• The power supply for the appliance must be brought into a switch...
53 Heat & Glo • 6000CL-IPI-S, 6000CL-IPI-T, 8000CL-IPI-S 8000CL-IPI-T • 2165-900 Rev. S • 9/12 13 Finishing A. Mantel and Wall Projections WARNING! Risk of Fire! Comply with all minimum clear- ances as specified. Framing closer than the minimums list - ed must be constructed entirely of noncombu...
Heat & Glo • 6000CL-IPI-S, 6000CL-IPI-T, 8000CL-IPI-S 8000CL-IPI-T • 2165-900 Rev. S • 9/12 54 Figure 13.4 Finishing Material 1 Inch Thick or Less DOOR FIT FINISH MATERIAL THICKNESS SEE FIGURE Folio Inside Any 13.6 Arcadia Overlap 1 inch or less 13.4 Inside Greater than 1 inch 13.5 Halston Overl...
55 Heat & Glo • 6000CL-IPI-S, 6000CL-IPI-T, 8000CL-IPI-S 8000CL-IPI-T • 2165-900 Rev. S • 9/12 DOOR FINISHING MATERIAL FINISHING MATERIAL C (Includes 1/8 in. opening each side of door) A (Outside door width) Finishing material thickness, 1-4 inches maximum B = Top of door to bottom of fireplace....
Heat & Glo • 6000CL-IPI-S, 6000CL-IPI-T, 8000CL-IPI-S 8000CL-IPI-T • 2165-900 Rev. S • 9/12 56 Removal of Finishing Strips Figure 13.7 Removing Finishing Strips. 31-7/8 IN. (6000) 33-11/16 IN. (8000) 3-3/4 IN. (6000, 8000) 35-5/16 IN. (6000) 43 IN. (8000) Figure 13.8. Clean Face Door Dimensions ...
57 Heat & Glo • 6000CL-IPI-S, 6000CL-IPI-T, 8000CL-IPI-S 8000CL-IPI-T • 2165-900 Rev. S • 9/12 D. Elevated Hearth Systems Use the table below to identify the hearth system that will be used. The table will also help identify effects on the various dimensions. Some hearth systems will elevate the...
Heat & Glo • 6000CL-IPI-S, 6000CL-IPI-T, 8000CL-IPI-S 8000CL-IPI-T • 2165-900 Rev. S • 9/12 58 A. Remove Fixed Glass Assembly See Section 14.I. B. Remove the Shipping Materials Remove shipping materials from inside or underneath the firebox. C. Clean the Appliance Clean/vacuum any sawdust that m...
59 Heat & Glo • 6000CL-IPI-S, 6000CL-IPI-T, 8000CL-IPI-S 8000CL-IPI-T • 2165-900 Rev. S • 9/12 Step 2. Right Refractory Panel Installation The right refractory panel has a rectangular notch on the bottom side.3. Place the right refractory panel against the right side- wall of the firebox. Rest t...
Heat & Glo • 6000CL-IPI-S, 6000CL-IPI-T, 8000CL-IPI-S 8000CL-IPI-T • 2165-900 Rev. S • 9/12 60 G. Ember Placement WARNING! Risk of Explosion! Follow ember placement instructions in manual. DO NOT completely block burner ports with ember material. Replace ember material annu- ally. Improperly pla...
61 Heat & Glo • 6000CL-IPI-S, 6000CL-IPI-T, 8000CL-IPI-S 8000CL-IPI-T • 2165-900 Rev. S • 9/12 H. Install the Log Assembly Log Assembly: LOGS-6CL Models: 6000CL-IPI-S, 6000CL-IPILP-S, 6000CL-IPI-T, 6000CL-IPILP-T CAUTION: Logs are fragile, handle with care. Log #1 (SRV2164-701) : Locate log plac...
Heat & Glo • 6000CL-IPI-S, 6000CL-IPI-T, 8000CL-IPI-S 8000CL-IPI-T • 2165-900 Rev. S • 9/12 62 Figure 11 6 5 7 2 3 1 4 Figure 7 2 3 1 Log #3 (SRV2164-703) : Mate the slot located on the bottom of Log #3 with the right log placement tab on top of Log #1. After slot and tab have been fitted togeth...
63 Heat & Glo • 6000CL-IPI-S, 6000CL-IPI-T, 8000CL-IPI-S 8000CL-IPI-T • 2165-900 Rev. S • 9/12 Log Assembly: LOGS-8CL Models: 8000CL-IPI-S, 8000CL-IPILP-S, 8000CL-IPI-T, 8000CL-IPILP-T Figure 3 Figure 4 GROOVES SLOTS Figure 5 Figure 6 1 2 1 LEFT GRATE TINE CAUTION: LOGS ARE FRAGILE, HANDLE WITH ...
Heat & Glo • 6000CL-IPI-S, 6000CL-IPI-T, 8000CL-IPI-S 8000CL-IPI-T • 2165-900 Rev. S • 9/12 64 Figure 11 1 2 3 4 5 6 7 Figure 7 2 3 1 1 2 3 4 Figure 8 Figure 9 Figure 10 1 1 2 2 3 3 4 5 5 6 4 Log #3 (SRV2168-703) : Mate the slot located on the bottom of Log #3 with the right log placement tab on...
65 Heat & Glo • 6000CL-IPI-S, 6000CL-IPI-T, 8000CL-IPI-S 8000CL-IPI-T • 2165-900 Rev. S • 9/12 Figure 14.5 Air Shutter Figure 14.4 Fixed Glass Assembly I. Fixed Glass Assembly WARNING! Risk of Asphyxiation! Handle fixed glass assembly with care. Inspect the gasket to ensure it is undamaged and i...
Heat & Glo • 6000CL-IPI-S, 6000CL-IPI-T, 8000CL-IPI-S 8000CL-IPI-T • 2165-900 Rev. S • 9/12 66 15 Troubleshooting With proper installation, operation, and maintenance your gas appliance will provide years of trouble-free service. If you do experience a problem, this troubleshooting guide will as...
Heat & Glo • 6000CL-IPI-S, 6000CL-IPI-T, 8000CL-IPI-S 8000CL-IPI-T • 2165-900 Rev. S • 9/12 68 16 Reference Materials A. Appliance Dimension Diagram Dimensions are actual appliance dimensions. Use for reference only. For framing dimensions and clearances refer to Section 5. Figure 16.1 Appliance...
Heat & Glo • 6000CL-IPI-S, 6000CL-IPI-T, 8000CL-IPI-S 8000CL-IPI-T • 2165-900 Rev. S • 9/12 70 B. Vent Components Diagrams Figure 16.3 DVP vent components Pipe Effective Length Inches Millimeters DVP4 4 102 DVP6 6 152 DVP12 12 305 DVP24 24 610 DVP36 36 914 DVP48 48 1219 DVP6A 3 to 6 76 to 152 DV...
71 Heat & Glo • 6000CL-IPI-S, 6000CL-IPI-T, 8000CL-IPI-S 8000CL-IPI-T • 2165-900 Rev. S • 9/12 DVP-HPC1 DVP-HPC2 DVP-TRAP1 DVP-TRAP2 DVP-HPCK1-B DVP-HPCK2-B DVP-TRAPK2 DVP-TRAPK1 DVP-TRAP Horizontal Termination Cap 15-1/8 in. (384 mm) 12 in. (305 mm) 8 in. (203 mm) Max Effective Length Note: Hea...
73 Heat & Glo • 6000CL-IPI-S, 6000CL-IPI-T, 8000CL-IPI-S 8000CL-IPI-T • 2165-900 Rev. S • 9/12 DVP-TB1 BasementVent Cap 12 in. (305 mm) 1-1/2 in. (38 mm) 7-3/8 in. (187 mm) 14 in. (356 mm) 17-3/4 in. (451 mm) 7-1/4 in. 12 in. 305 mm (184 mm) 5-1/4 in. (133 mm) 12-1/2 in. (318 mm) DVP-TVHW Vertic...
Heat & Glo • 6000CL-IPI-S, 6000CL-IPI-T, 8000CL-IPI-S 8000CL-IPI-T • 2165-900 Rev. S • 9/12 74 B. Vent Components Diagrams (continued) DVP-HRC-SS DVP-HRC-ZC-SS HORIZONTAL TERMINATION CAP 13 in. (330 mm) 15 in. (381 mm) 8-1/8 in. (206 mm) 10-7/8 in. 276 mm 10-1/2 in. 267 mm 3° 87° Effective Lengt...
75 Heat & Glo • 6000CL-IPI-S, 6000CL-IPI-T, 8000CL-IPI-S 8000CL-IPI-T • 2165-900 Rev. S • 9/12 B. Vent Components Diagrams (continued) Figure 16.8 SLP Series Vent Components 8-3/4 in. 222 mm 6-1/2 in. 165 mm 6-5/8 in. 168 mm 6 in. 152 mm 6-1/2 in. 165 mm 6-5/8 in. 168 mm 9-7/8 in. 251 mm 6-1/2 i...
Heat & Glo • 6000CL-IPI-S, 6000CL-IPI-T, 8000CL-IPI-S 8000CL-IPI-T • 2165-900 Rev. S • 9/12 76 B. Vent Components Diagrams (continued) Figure 16.9 SLP Series Vent Components SLP-WT-BK Wall Thimble-Black 26 in. 660 mm DVP-HSM-B Extended Heat Shield SLP-TRAP Horizontal Termination Cap 15-1/8 in. (...
Heat & Glo • 6000CL-IPI-S, 6000CL-IPI-T, 8000CL-IPI-S 8000CL-IPI-T • 2165-900 Rev. S • 9/12 78 Service Parts Beginning Manufacturing Date: Aug 2009 Ending Manufacturing Date: Active IMPORTANT: THIS IS DATED INFORMATION. When requesting service or replacement parts for your appliance please provi...
Heat & Glo • 6000CL-IPI-S, 6000CL-IPI-T, 8000CL-IPI-S 8000CL-IPI-T • 2165-900 Rev. S • 9/12 82 D. Contact Information Please contact your Heat & Glo dealer with any questions or concerns. For the location of your nearest Heat & Glo dealer, please visit www.heatnglo.com. - NOTES - _______...
Heat & Glo Manuals
-
Heat & Glo SL-550TV-IPI-E
Manual
-
Heat & Glo CF750ENH
Manual
-
Heat & Glo ST-HV-IPI
Manual
-
Heat & Glo 6000GLX-IPILP-S/-R
Manual
-
Heat & Glo st-42tvfl
Manual
-
Heat & Glo 7000XLS
Manual
-
Heat & Glo 8000TV-OAK-IPI
Manual
-
Heat & Glo EM-415 - 36
Manual
-
Heat & Glo 350TRSILP-AUF
Manual
-
Heat & Glo Exclaim-50
Manual
-
Heat & Glo 6000 Series
Manual
-
Heat & Glo XLR-PLUS-N-AU
Manual
-
Heat & Glo 8000CFLP-OAKIPI
Manual
-
Heat & Glo BE-41C
Manual
-
Heat & Glo VRT-GY-P-AUB
Manual
-
Heat & Glo ST-36TRLP-IPI
Manual
-
Heat & Glo SL-550TV-D
Manual
-
Heat & Glo 6000GL-IPILP-S
Manual
-
Heat & Glo BW36
Manual
-
Heat & Glo EM-485TH
Manual