Page 2 - Jumpers and Connectors; Jumpers; System Board Jumpers
Back to Contents Page Jumpers and Connectors Dell™ PowerEdge™ 2850 Systems Installation and Troubleshooting Guide Jumpers —A General Explanation System Board Jumpers System Board Connectors Expansion-Card Riser-Board Components and PCI Buses SCSI Backplane Board Connectors Disab...
Page 3 - System Board Connectors
Table A- 1. System Board Jumper Settings System Board Connectors See Figure A -3 and Table A -2 for the location and description of system board connectors. Figure A- 3. System Board Connectors Jumper Setting Description PASSWD (default) The password feature is enabled. The password f...
Page 4 - Expansion-Card Riser-Board Components and PCI Buses
Table A- 2. System Board Connectors Expansion-Card Riser-Board Components and PCI Buses Figure A -4 shows the components on the PCI-X expansion-card riser board, including the expansion-card slots and buses. Table 6 -1 lists the PCI bus and operating speed for each expansion-card slot. Figure A ...
Page 5 - SCSI Backplane Board Connectors; Disabling a Forgotten Password
Figure A -5 shows the components on the optional PCI-X/PCIe expansion-card riser board, including the expansion-card slots and buses. Table 6 -2 lists the PCI bus and operating speed for each expansion-card slot. Figure A- 5. Optional PCI- X/PCIe Expansion- Card Riser Board Components SCSI Backp...
Page 7 - Serial Connector; Serial Connector Autoconfiguration
Back to Contents Page I/O Connectors Dell™ PowerEdge™ 2850 Systems Installation and Troubleshooting Guide Serial Connector PS/2-Compatible Keyboard and Mouse Connectors Video Connector USB Connectors Integrated NIC Connectors Network Cable Requirements I/O connectors are the gate...
Page 8 - PS/2-Compatible Keyboard and Mouse Connectors; Video Connector
Table B- 2. Serial Connector Pin Assignments PS/2-Compatible Keyboard and Mouse Connectors The PS/2-compatible keyboard and mouse cables attach to 6-pin, miniature DIN connectors. Figure B -3 illustrates the pin numbers for these connectors and Table B -3 defines the pin assignments for these c...
Page 9 - USB Connectors; Integrated NIC Connectors
USB Connectors The system's USB connectors support USB-compliant peripherals such as keyboards, mice, and printers and may also support USB-compliant devices such as diskette drives and optical drives. Figure B -5 illustrates the pin numbers for the USB connector and Table B -5 defines the pin ass...
Page 10 - Network Cable Requirements
Network Cable Requirements The NIC supports a UTP Ethernet cable equipped with a standard RJ45-compatible plug. Observe the following cabling restrictions. l Use Category 5 or greater wiring and connectors. l Do not exceed a cable run length (from a workstation to a hub) of 100 m (328 ft). For...
Page 11 - Introduction; Other Documents You May Need; Obtaining Technical Assistance
Back to Contents Page Introduction Dell™ PowerEdge™ 2850 Systems Installation and Troubleshooting Guide Other Documents You May Need Obtaining Technical Assistance Your high-speed system offers significant service and upgrade features. The system includes the following service features to ma...
Page 12 - Indicators on the Optional Bezel; Front-Panel Indicators and Features
Back to Contents Page Indicators, Messages, and Codes Dell™ PowerEdge™ 2850 Systems Installation and Troubleshooting Guide Indicators on the Optional Bezel Front-Panel Indicators and Features SCSI Hard-Drive Indicator Codes Back-Panel Indicators and Features Power Indicator Codes ...
Page 13 - SCSI Hard-Drive Indicator Codes
Table 2- 2. Front- Panel LED Indicators, Buttons, and Connectors SCSI Hard-Drive Indicator Codes If RAID is activated, two indicators on each of the hard-drive carriers provide information on the status of the SCSI hard drives. RAID can be enabled either by using ROMB on the optional riser card...
Page 14 - Back-Panel Indicators and Features
Table 2 -3 lists the drive indicator patterns. Different patterns are displayed as drive events occur in the system. For example, if a hard-drive fails, the "drive failed" pattern appears. After the drive is selected for removal, the "drive being prepared for removal" pattern appears...
Page 15 - Power-Button Indicator Codes; NIC Indicator Codes
Power Indicator Codes The system has indicators on the front panel and the power supplies that signify system power status. Power-Button Indicator Codes The power button on the front panel controls the power input to the system's power supplies. The power indicator can provide information on pow...
Page 18 - Solving Problems Described by LCD Status Messages; Removing LCD Status Messages; System Messages
Solving Problems Described by LCD Status Messages When a single message appears on the status LCD, locate the code in Table 2 -8 and perform the suggested corrective action. The code on the LCD can often specify a very precise fault condition that is easily corrected. For example, if the code E078...
Page 21 - System Beep Codes
System Beep Codes If an error that cannot be reported on the screen occurs during POST, the system may emit a series of beeps that identifies the problem. Processor n internal error Faulty microprocessor; faulty system board. See " Troubleshooting the Microprocessors " in "Troubleshoot...
Page 23 - Alert Messages
Warning Messages A warning message alerts you to a possible problem and prompts you to respond before the system continues a task. For example, before you format a diskette, a message will warn you that you may lose all data on the diskette. Warning messages usually interrupt the task and require ...
Page 24 - Finding Software Solutions; Before You Begin; Input Errors
Back to Contents Page Finding Software Solutions Dell™ PowerEdge™ 2850 Systems Installation and Troubleshooting Guide Before You Begin Troubleshooting Errors and Conflicts Software problems can be caused by: l Improper installation or configuration of an application l Application conflic...
Page 26 - Running System Diagnostics; Using Server Administrator Diagnostics; System Diagnostics Features; When to Use the System Diagnostics; From the Utility Partition; From the Diagnostics Diskettes
Back to Contents Page Running System Diagnostics Dell™ PowerEdge™ 2850 Systems Installation and Troubleshooting Guide Using Server Administrator Diagnostics System Diagnostics Features When to Use the System Diagnostics Running the System Diagnostics System Diagnostics Testing Optio...
Page 27 - Using the Advanced Testing Options
1. Create a set of diagnostics diskettes from the Dell OpenManage Server Assistant CD. See "Using the Dell OpenManage Server Assistant CD" in your User's Guide for information on creating the diskettes. 2. Insert the first diagnostics diskette. 3. Reboot the system. If the system fails...
Page 28 - Troubleshooting Your System; Safety First; Checking the Equipment; Troubleshooting the Video Subsystem
Back to Contents Page Troubleshooting Your System Dell™ PowerEdge™ 2850 Systems Installation and Troubleshooting Guide Safety First — For You and Your System To perform certain procedures in this document, you must remove the system cover and work inside the system. While working inside th...
Page 30 - Troubleshooting Basic I/O Functions; Troubleshooting a Serial I/O Device
If the problem is resolved, replace the faulty mouse. See " Getting Help ." 5. Enter the System Setup program and ensure that the mouse controller is enabled. See "Using the System Setup Program" in your User's Guide . If the problem is not resolved, see " Getting Help ." ...
Page 31 - Troubleshooting a NIC; Inside the System
2. Turn off the system and any USB devices. 3. Disconnect the USB devices, and connect the malfunctioning device to the other USB connector. 4. Turn on the system and the reconnected device. If the problem is resolved, the USB connector might be defective. See " Getting Help ." 5. If...
Page 32 - Removing the Bezel; Replacing the Bezel
In Figure 5 -1 , the covers and bezel are removed to provide an interior view of the system. Figure 5- 1. Inside the System The system board holds the system's control circuitry and other electronic components. Several hardware options, such as the microprocessors and memory, are installed directl...
Page 33 - Closing the System; Troubleshooting a Wet System
1. Fit the tabs on the right end of the bezel into the corresponding slots in the front panel. 2. Rotate the left end of the bezel toward the system to secure the left end of the bezel. 3. Using the system key, lock the bezel. Opening the System To upgrade or troubleshoot the system, remov...
Page 34 - Troubleshooting a Damaged System; Troubleshooting the System Battery
l Excessive humidity. Action 1. Turn off the system and attached peripherals, and disconnect the system from the electrical outlet. 2. Open the system. See " Opening the System ." 3. Remove all expansion cards installed in the system. See " Removing an Expansion Card " in...
Page 35 - Troubleshooting Power Supplies; Troubleshooting System Cooling Problems
Problem l System message indicates a problem with the battery. l System Setup program loses system configuration information. l System date and time do not remain current. Action 1. Re-enter the time and date through the System Setup program. See "Using the System Setup Program" ...
Page 36 - Troubleshooting a Fan; Troubleshooting System Memory
Problem l Systems management software issues a fan-related error message. Action Ensure that none of the following conditions exist: l Ambient temperature is too high. l External airflow is obstructed. l Cables inside the system obstruct airflow. l An individual cooling fan has failed. S...
Page 37 - Troubleshooting a Diskette Drive
1. Run the appropriate online diagnostic test. See " Using Server Administrator Diagnostics " in "Running System Diagnostics." 2. Turn on the system and attached peripherals. If an error messages does not appear, go to step 12 . 3. Enter the System Setup program and check the s...
Page 38 - Troubleshooting an Optical Drive
2. Open or remove the bezel. See " Removing the Bezel ." 3. Run the appropriate online diagnostic test. See " Using Server Administrator Diagnostics " in "Running System Diagnostics." 4. Turn off the system and attached peripherals, and disconnect the system from the el...
Page 39 - Troubleshooting an External SCSI Tape Drive
1. Try using a different CD that you know works properly. 2. Enter the System Setup program and ensure that the drive's IDE or SCSI controller is enabled. See "Using the System Setup Program" in the User's Guide . 3. Run the appropriate online diagnostic test. See " Using Server Ad...
Page 40 - Troubleshooting SCSI Hard Drives; Troubleshooting a SCSI Hard Drive (System With a SCSI Backplane)
11. Close the system. See " Closing the System ." 12. Reconnect the system to the electrical outlet, and turn on the system, including attached peripherals. 13. If the problem is not resolved, see the documentation for the tape drive for additional troubleshooting instructions. 14. I...
Page 41 - Troubleshooting an Integrated RAID Controller; Troubleshooting a RAID Controller Card
If the problem persists, see " Getting Help ." Troubleshooting an Integrated RAID Controller Problem l Error message indicates an integrated RAID controller problem. Action 1. Run the appropriate online diagnostic test. See " Using Server Administrator Diagnostics " in ...
Page 42 - Troubleshooting Expansion Cards
Problem l Error message indicates a RAID controller problem. l RAID controller performs incorrectly or not at all. Action 1. Run the appropriate online diagnostic test. See " Using Server Administrator Diagnostics " in "Running the System Diagnostics." 2. Remove the bez...
Page 43 - Troubleshooting the Microprocessors
8. Turn off the system and attached peripherals, and disconnect the system from the electrical outlet. 9. Open the system. See " Opening the System ." 10. Remove all expansion cards installed in the system. See "Removing an Expansion Card" in "Installing System Options." ...
Page 45 - Installing System Options; System Fans; Removing a Cooling Fan
Back to Contents Page Installing System Options Dell™ PowerEdge™ 2850 Systems Installation and Troubleshooting Guide System Fans Power Supplies Expansion-Card Cage Expansion Cards System Memory Processors System Battery Installing an Optional RAC Card This section describes...
Page 46 - Replacing a Cooling Fan; Power Supplies; Removing a Power Supply; Replacing a Power Supply; Expansion-Card Cage; Removing the Expansion-Card Cage
Replacing a Cooling Fan 1. Ensure that the fan handle is upright and lower the fan into its retention base until the fan is fully seated. Then lower the fan handle until it snaps into place. See Figure 6 -1 . 2. Close the system. See " Closing the System " in "Troubleshooting Your ...
Page 47 - Replacing the Expansion-Card Cage
1. Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet. 2. Open the system. See " Opening the System " in "Troubleshooting Your System." 3. Disconnect all expansion-card cables. 4. Rotate the expansion-card cage leve...
Page 48 - Expansion Cards; Expansion Card Installation Guidelines; PCI-X Riser Board Expansion Slots; Optional PCI-X/PCIe Riser Board Expansion Slots; Installing an Expansion Card
Expansion Cards The system is available with a PCI-X riser board or an optional PCI-X/PCI Express (PCIe) riser board. The PCI-X riser board provides three PCI-X expansion slots and the PCI-X/PCIe riser board provides one PCI-X expansion slot, one PCIe x4-lane expansion slot, and one PCIe x8-lane e...
Page 49 - Removing an Expansion Card
4. Disconnect all expansion-card cables. 5. Remove the expansion-card cage. See " Removing the Expansion-Card Cage ." 6. Position the expansion-card cage so that the riser board lies horizontally or vertically on your work surface. 7. Open the expansion-card guide latch and remove the ...
Page 50 - System Memory; General Memory Module Installation Guidelines
a. Open the expansion-card latch. See Figure 6 -4 . b. Grasp the expansion card by its top corners, and carefully remove it from the expansion- card connector. 7. If you are removing the card permanently, install a metal filler bracket over the empty expansion slot opening and close the expans...
Page 51 - Installing Memory Modules
Table 6- 4. Allowable Memory Module Configurations – Single- Ranked and Dual- Ranked Memory Modules Installing Memory Modules 1. Open the system. See " Opening the System " in Troubleshooting Your System." 2. Lift up the memory module shroud. 3. Locate the memory module socke...
Page 52 - Removing Memory Modules; Processors; Replacing the Processor
6. Press down on the memory module with your thumbs while pulling up on the ejectors with your index fingers to lock the memory module into the socket. When the memory module is properly seated in the socket, the ejectors on the memory module socket align with the ejectors on the other sockets tha...
Page 54 - System Battery; Replacing the System Battery
9. Unpack the new processor. If any of the pins on the processor appear bent, see " Getting Help ." 10. Align the pin-1 corner of the processor with the pin-1 corner of the ZIF socket. See Figure 6 -7 . Identify the pin-1 corner of the processor by locating the tiny gold triangle on one ...
Page 55 - Installing an Optional RAC Card
1. Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet. 2. Open the system. See " Opening the System " in "Troubleshooting Your System." 3. Lift up the memory airflow shroud. 4. Locate the battery socket. See Figure A ...
Page 58 - Installing Drives; SCSI Interface Cables; SCSI ID Numbers; External SCSI Tape Drive; Installing an External SCSI Tape Drive
Back to Contents Page Installing Drives Dell™ PowerEdge™ 2850 Systems Installation and Troubleshooting Guide SCSI Interface Cables SCSI Configuration Information External SCSI Tape Drive SCSI Hard Drives Optical and Diskettes Drives Activating the Integrated RAID Controller In...
Page 59 - Installing an Internal SCSI Tape Drive; SCSI Hard Drives; SCSI Backplane Board Configuration
4. Reconnect the system to its electrical outlet and turn the system on, including any attached peripherals. 5. Perform a tape backup and verification test with the drive as instructed in the software documentation that came with the drive. Installing an Internal SCSI Tape Drive 1. Turn off ...
Page 60 - Installing a SCSI Hard Drive; Removing a SCSI Hard Drive
l SCSI controller: ¡ Integrated SCSI controller ¡ Optional integrated RAID controller. See " Activating the Integrated RAID Controller ." ¡ RAID controller card. See " Installing a RAID Controller Card ." l Cabling: ¡ If a RAID controller card is not installed, connect th...
Page 61 - Optical and Diskettes Drives; Removing the Optical Drive or Diskette Drive Tray; Installing the Optical Drive or Diskette Drive Tray
If the drive has been online, the drive status indicator will blink green two times a second as the drive is powered down. When all indicators are off, the drive is ready for removal. See your operating system documentation for more information on taking the hard drive offline. 3. Open the hard-dr...
Page 62 - Activating the Integrated RAID Controller
4. Replace the bezel. See " Replacing the Bezel " in "Troubleshooting Your System." 5. Reconnect your system and peripherals to their electrical outlets, and turn on the system. Activating the Integrated RAID Controller 1. Turn off the system, including any attached periphe...
Page 63 - Installing a RAID Controller Card
12. Gently pull and hold open the RAID battery compartment tab, route the RAID battery cable through the bottom opening, and then lower the RAID battery into the compartment. See Figure 7 -5 . 13. Route the battery cable through the battery-cable securing clip and connect the battery cable to th...
Page 64 - Installing a SCSI Backplane Daughter Card
1. Unpack the RAID controller card and prepare it for installation. For instructions, see the documentation accompanying the card. 2. Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet. 3. Open the system. See " Opening the System ...
Page 65 - Configuring the Boot Device
7. Reconfigure the SCSI cable connections to the SCSI backplane as necessary to operate the backplane as a 2/4 split backplane: l If a RAID controller card is not installed, connect the appropriate SCSI cables between the SCSI A and/or SCSI B connectors on riser board and the SCSI A or SCSI B co...
Page 66 - Technical Assistance; Online Services
Back to Contents Page Getting Help Dell™ PowerEdge™ 2850 Systems Installation and Troubleshooting Guide Technical Assistance Dell Enterprise Training and Certification Problems With Your Order Product Information Returning Items for Warranty Repair or Credit Before You Call De...
Page 67 - Dell Enterprise Training and Certification
support.jp.dell.com (Japan only) support.euro.dell.com (Europe only) l Electronic Quote Service [email protected] [email protected] (Asian/Pacific countries only) [email protected] (Canada only) l Electronic Information Service [email protected] AutoTech Service Dell's automated technical supp...
Page 68 - Dell Contact Numbers
the system diagnostics. 4. Include any accessories that belong with the item(s) being returned (such as power cables, media such as CDs and diskettes, and guides) if the return is for credit. 5. Pack the equipment to be returned in the original (or equivalent) packing materials. You are responsi...