Daikin RXQ5M9W1B- User Manual

Daikin RXQ5M9W1B

Daikin RXQ5M9W1B– User Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
29 Page 29
30 Page 30
31 Page 31
32 Page 32
Page: / 32

Table of Contents:

  • Page 2 – TABLE OF CONTENTS
  • Page 3 – Ou; Specifications; -1 TECHNICAL SPECIFICATIONS
  • Page 5 – -2 ELECTRICAL SPECIFICATIONS
  • Page 6 – Options
  • Page 7 – Capacity tables; - 1 Cooling capacity tables
  • Page 8 – - 1 Cooling capacity tables
  • Page 13 – Capacity correction factor
  • Page 16 – Dimensional drawing & centre of gravity; - 1 Dimensional drawing
  • Page 17 – - 1 Dimensional drawing
  • Page 18 – - 2 Centre of gravity
  • Page 19 – - 2 Centre of gravity
  • Page 20 – Piping diagram
  • Page 22 – Wiring diagram
  • Page 23 – - 1 Wiring diagram
  • Page 24 – - 2 External connection diagram
  • Page 25 – Sound level; - 1 Sound pressure spectrums
  • Page 26 – - 2 Sound power spectrums
  • Page 27 – Installation
  • Page 28 – - 2 Fixation and foundation of units
  • Page 29 – - 3 Refrigerant pipe selection
  • Page 30 – - 3 Refrigerant pipe selection
  • Page 31 – Operation range; Cooling
  • Page 32 – Systems
Loading the manual

technical data

Systems

RXQ-M9W1B

VRVII Cooling only system

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - TABLE OF CONTENTS

3 • VRVII Systems • Outdoor Units 1 • Outdoor Units • VRV COOLING ONLY SYSTEM • RXQ5-10M9W1B TABLE OF CONTENTS RXQ5-10M9W1B RX Q5 -1 0M 9W 1B 7 Ou td oo r Un it s VR VI I Sy st em s V R V C o o l i n g O n l y S y s 1 Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ....

Page 3 - Ou; Specifications; -1 TECHNICAL SPECIFICATIONS

• Outdoor Units • VRV COOLING ONLY SYSTEM • RXQ5-10M9W1B 1 • VRVII Systems • Outdoor Units 2 Ou td oo VR VI I RX Q5 -1 0 V R V C o 1 Specifications 1-1 TECHNICAL SPECIFICATIONS RXQ5M9W1B RXQ8M9W1B RXQ10M9W1B Capacity Cooling kW 14.00 22.40 28.00 Capacity range HP 5 8 10 Power input (Nominal) Cooling...

Page 5 - -2 ELECTRICAL SPECIFICATIONS

• Outdoor Units • VRV COOLING ONLY SYSTEM • RXQ5-10M9W1B 1 • VRVII Systems • Outdoor Units 4 1-2 ELECTRICAL SPECIFICATIONS RXQ5M9W1B RXQ8M9W1B RXQ10M9W1B Power Supply Name W1 Phase 3N Frequency Hz 50 50 50 Voltage V 400 400 400 Current Nominal running current (RLA) Cooling A 6.50 12.00 12.60 Startin...

Other Daikin Models

All Daikin Other