Daikin 3P207257-3- Installation Manual
Daikin 3P207257-3– Installation Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 2 – WARNING
- Page 3 – OUTDOOR UNIT
- Page 4 – Indoor/Outdoor Unit Installation Drawings; Be sure to connect at least 2 rooms.; CAUTION; Clamping material
- Page 5 – Installation; Install the unit horizontally.; Precautions on Installation
- Page 6 – Shortest allowable length per room is 9.8ft.
- Page 7 – to never insert drain sockets into the wrong drain holes; NOTE; Refrigerant Piping; to
- Page 8 – Check the machine nameplate; Precautions when adding R410A; Evacuation for; at least 1 hour; ) Remove covers from liquid stop value and gas stop valve.
- Page 9 – Flaring the Pipe End; Charging with Refrigerant; Cautions on Pipe Handling; Selection of copper and heat insulation materials; reduces
- Page 11 – Forced Operation; ground
- Page 12 – Ground; so that the terminal numbers match.; Be sure to match the symbols for wiring and piping.
- Page 13 – Priority Room Setting; About the Priority Room Setting function; ) Operation mode priority; Be sure to only set one room
- Page 14 – Night Quiet Mode setting; About Night Quiet Mode; Setting procedure; JST products; Arrow view
- Page 15 – Wiring Error Check; All; Wiring correct example
- Page 16 – ATTENTION; Test Run and Final Check
• Read these Safety Precautions carefully to ensure correct installation.
• This manual classifies the precautions into DANGER, WARNING and CAUTION. Be sure to follow all the
precautions below: they are all important for ensuring safety.
• After completing installation, test the unit to check for installation errors. Give the user adequate instructions
concerning the use and cleaning of the unit according to the Operation Manual.
• Refrigerant gas is heavier than air and replaces oxygen. A massive leak could lead to oxygen depletion, especially in
basements, and an asphyxiation hazard could occur leading to serious injury or death.
• Do not install unit in an area where flammable materials are present due to risk of explosion resulting in serious
injury or death.
• If the refrigerant gas leaks during installation, ventilate the area immediately.
Refrigerant gas may produce a toxic gas if it comes in contact with fire such as from a fan heater, stove or cooking device.
Exposure to this gas could cause severe injury or death.
• After completing the installation work, check that the refrigerant gas does not leak.
Refrigerant gas may produce a toxic gas if it comes in contact with fire such as from a fan heater, stove or cooking device.
Exposure to this gas could cause severe injury or death.
• Do not ground units to water pipes, telephone wires or lightning rods because incomplete grounding could cause a
severe shock hazard resulting in severe injury or death, and to gas pipes because a gas leak could result in an
explosion which could lead to severe injury or death.
• Do not ground units to telephone wires or lightning rods because lightning strikes could cause a severe shock hazard
resulting in severe injury or death, and to gas pipes because a gas leak could result in an explosion which could lead
to severe injury or death.
• Safely dispose of the packing materials.
Packing materials, such as nails and other metal or wooden parts, may cause stabs or other injuries.
Tear apart and throw away plastic packaging bags so that children will not play with them.
Children playing with plastic bags face the danger of death by suffocation.
• The following safety symbols are used throughout this manual:
Be sure to observe this instruction.
Be sure to establish
a
ground
connection.
Never attempt.
Indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury.
Failure to follow any of WARNING is likely to result in such grave consequences as death or serious injury.
Failure to follow any of CAUTION may in some cases result in grave consequences.
3P207257-3
M07B061
Safety Precautions (1)
DAIKIN AIR CONDITIONER
Two-dimensional bar code
is a code for manufacturing.
DANGER
WARNING
CAUTION
DANGER
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
• Installation should be left to the authorized dealer or another trained professional. Improper installation may cause water leakage, electrical shock, fire, or equipment damage. • Do not install the air conditioner where gas leakage would be exposed to open flames. If the gas leaks and builds up a...
Accessories supplied with the outdoor unit: Accessories Precautions for Selecting the Location (A) Installation Manual (C) Reducer assy (B) Drain socket assy Cannot be installed hanging from ceiling or stacked. 1 1 1 OUTDOOR UNIT 1) Choose a place solid enough to bear the weight and vibration of the...
Indoor/Outdoor Unit Installation Drawings For installation of the indoor units, refer to the installation manual which was provided with the units.(The diagram shows a wall-mounted indoor unit.) 1) Do not connect the embedded branch piping and the outdoor unit when only carrying out piping work with...