Page 2 - • Split Sky Air • Outdoor Units; Specifications; -1 TECHNICAL SPECIFICATIONS
3 1 2 • Split Sky Air • Outdoor Units 2 • Outdoor Units • R-410A • MKS-FV1B_F2V1B 2 Specifications 2-1 TECHNICAL SPECIFICATIONS 2MKS40FV1B 4MKS75F2V1B Casing Colour Ivory White Dimensions Unit Height mm 550 735 Width mm 765 936 Depth mm 285 300 Packing Height mm 612 797 Width mm 906 992 Depth mm 364...
Page 3 - -2 ELECTRICAL SPECIFICATIONS
• Outdoor Units • R-410A • MKS-FV1B_F2V1B 1 2 • Split Sky Air • Outdoor Units 3 2 Specifications Piping connections Liquid (OD) Quantity 2 4 Diameter (OD) mm 6.35 6.35 Gas Quantity 2 2 Diameter (OD) mm 9.5 9.5 Quantity 1 Diameter (OD) mm 12.7 Quantity 1 Diameter (OD) mm 15.9 Drain Quantity 1 1 Diame...
Page 4 - Electrical data; SYMBOLS
3 1 3 • Split Sky Air • Outdoor Units 4 • Outdoor Units • R-410A • MKS-FV1B_F2V1B 3 Electrical data 3D055826 SYMBOLS MCA : Min. Circuit Amps (A) MFA : Max. Fuse Amps (See note 6). (A) MSC : MSC means the max. current during the starting of compressor. (A) RLA : Rated Load Amps (A) OFM : Outdoor Fan ...
Page 6 - Capacity tables; - 1 Combination table; NOTES
3 1 4 • Split Sky Air • Outdoor Units 6 • Outdoor Units • R-410A • MKS-FV1B_F2V1B 4 Capacity tables 4 - 1 Combination table Cooling [50Hz 230V] Outdoor unit Combination of indoor unit Capacity of each indoor unit Each capacity (kW) Total capacity (kW) Total input (W) Total current (A) Power factor %...
Page 11 - - 2 Cooling capacity tables
• Outdoor Units • R-410A • MKS-FV1B_F2V1B 1 4 • Split Sky Air • Outdoor Units 11 4 Capacity tables 4 - 2 Cooling capacity tables 2MKS40FV1B Cooling [50Hz 230V] Combination (Capacity) Outdoor air temp. °CDB Indoor air temp.: °CWB 14°C 16°C 18°C 19°C 22°C 24°C TC PI TC PI TC PI TC PI TC PI TC PI kW kW...
Page 47 - Dimensional drawing & centre of gravity; - 1 Dimensional drawing
• Outdoor Units • R-410A • MKS-FV1B_F2V1B 1 5 • Split Sky Air • Outdoor Units 47 5 Dimensional drawing & centre of gravity 5 - 1 Dimensional drawing 3D054872 2MKS40FV1B 4-holes for anchor bolts (M8 or M10) Drain outlet (I.D. J 15.9 hose for connection) Handle 2-Terminal strip with earth terminal...
Page 48 - - 2 Centre of gravity
3 1 5 • Split Sky Air • Outdoor Units 48 • Outdoor Units • R-410A • MKS-FV1B_F2V1B 5 Dimensional drawing & centre of gravity 5 - 2 Centre of gravity 2MKS40FV1B 4D055810 4D037024L 4MKS75F2V1B Anchor bolts
Page 49 - Piping diagram
• Outdoor Units • R-410A • MKS-FV1B_F2V1B 1 6 • Split Sky Air • Outdoor Units 49 6 Piping diagram 3D055809 2MKS40FV1B Heat exchanger Room A (6.4 CuT) Room B (6.4 CuT) Gas pipe thermistor Field piping liquid Field piping gas Room A (9.5 CuT) Room B (9.5 CuT) Liquid line stop valve Muffler Muffler Hea...
Page 50 - Wiring diagram
3 1 7 • Split Sky Air • Outdoor Units 50 • Outdoor Units • R-410A • MKS-FV1B_F2V1B 7 Wiring diagram 7 - 1 Wiring diagram 3D055671 2MKS40FV1B C74, C75, C94 C95, C100 : Capacitor DB1, DB2 : Diode bridge FU1, FU2, FU3 : Fuse IC11 : Solid state relay IPM1 : Intelligent power module L : Live L1 : Coil L1...
Page 51 - Sound data; - 1 Sound pressure spectrum
• Outdoor Units • R-410A • MKS-FV1B_F2V1B 1 8 • Split Sky Air • Outdoor Units 51 8 Sound data 8 - 1 Sound pressure spectrum 4D055817 Octav e ban d soun d pressur e level dB:(0d B = 0.0002 µ bar) Octave band center frequency (Hz) 2MKS40FV1B Legend 220 ∼ 240V 50Hz approximate threshold hearing for con...
Page 52 - Operation range
3 1 9 • Split Sky Air • Outdoor Units 52 • Outdoor Units • R-410A • MKS-FV1B_F2V1B 9 Operation range 2MKS40FV1B Outdoo rtemperatur e (°CDB) Continuou s operation Pull-dow n period Indoor temp. (°CWB) Notes: The graphs are based on the following conditions: d Equivalent piping length 5.0m d Level dif...