- Page 2 – • Split Sky Air • Outdoor Units; Specifications; -1 TECHNICAL SPECIFICATIONS
- Page 3 – -2 ELECTRICAL SPECIFICATIONS
- Page 4 – Electrical data; SYMBOLS
- Page 6 – Capacity tables; - 1 Combination table; NOTES
- Page 11 – - 2 Cooling capacity tables
- Page 47 – Dimensional drawing & centre of gravity; - 1 Dimensional drawing
- Page 48 – - 2 Centre of gravity
- Page 49 – Piping diagram
- Page 50 – Wiring diagram
- Page 51 – Sound data; - 1 Sound pressure spectrum
- Page 52 – Operation range
• Outdoor Units • R-410A • MKS-FV1B_F2V1B
1
1
• Split Sky Air • Outdoor Units
1
1
Features
Ou
td
oo
r
Un
i
Sp
li
t
Sk
y
A
MK
S-
FV
1B
_F
2V
1
R-
41
0a
•
Outdoor units for Multi model application.
•
Up to 5 indoor units can be connected to 1 Multi outdoor unit. All
indoor units are individually controllable with remote control and do
not need to be installed in the same room or at the same time. They
operate simultaneously within the same cooling operation
•
It is possible to combine different types of indoor units as well. (e.g.
wall mounted, ceiling mounted cassette corner, concealed ceiling
unit)
•
Daikin outdoor units are neat and sturdy and can be mounted easily
on a roof or terrace or simply placed against an outside wall.
•
Outdoor units are fitted with a swing compressor, renowned for its low
noise and high energy efficiency
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
3 1 2 • Split Sky Air • Outdoor Units 2 • Outdoor Units • R-410A • MKS-FV1B_F2V1B 2 Specifications 2-1 TECHNICAL SPECIFICATIONS 2MKS40FV1B 4MKS75F2V1B Casing Colour Ivory White Dimensions Unit Height mm 550 735 Width mm 765 936 Depth mm 285 300 Packing Height mm 612 797 Width mm 906 992 Depth mm 364...
• Outdoor Units • R-410A • MKS-FV1B_F2V1B 1 2 • Split Sky Air • Outdoor Units 3 2 Specifications Piping connections Liquid (OD) Quantity 2 4 Diameter (OD) mm 6.35 6.35 Gas Quantity 2 2 Diameter (OD) mm 9.5 9.5 Quantity 1 Diameter (OD) mm 12.7 Quantity 1 Diameter (OD) mm 15.9 Drain Quantity 1 1 Diame...
3 1 3 • Split Sky Air • Outdoor Units 4 • Outdoor Units • R-410A • MKS-FV1B_F2V1B 3 Electrical data 3D055826 SYMBOLS MCA : Min. Circuit Amps (A) MFA : Max. Fuse Amps (See note 6). (A) MSC : MSC means the max. current during the starting of compressor. (A) RLA : Rated Load Amps (A) OFM : Outdoor Fan ...