Page 2 - TABLE OF CONTENTS
3 • VRVII Systems • Outdoor Units 1 • Outdoor Units • VRV COOLING ONLY SYSTEM • RXQ5-10M9W1B TABLE OF CONTENTS RXQ5-10M9W1B RX Q5 -1 0M 9W 1B 7 Ou td oo r Un it s VR VI I Sy st em s V R V C o o l i n g O n l y S y s 1 Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ....
Page 3 - Ou; Specifications; -1 TECHNICAL SPECIFICATIONS
• Outdoor Units • VRV COOLING ONLY SYSTEM • RXQ5-10M9W1B 1 • VRVII Systems • Outdoor Units 2 Ou td oo VR VI I RX Q5 -1 0 V R V C o 1 Specifications 1-1 TECHNICAL SPECIFICATIONS RXQ5M9W1B RXQ8M9W1B RXQ10M9W1B Capacity Cooling kW 14.00 22.40 28.00 Capacity range HP 5 8 10 Power input (Nominal) Cooling...
Page 5 - -2 ELECTRICAL SPECIFICATIONS
• Outdoor Units • VRV COOLING ONLY SYSTEM • RXQ5-10M9W1B 1 • VRVII Systems • Outdoor Units 4 1-2 ELECTRICAL SPECIFICATIONS RXQ5M9W1B RXQ8M9W1B RXQ10M9W1B Power Supply Name W1 Phase 3N Frequency Hz 50 50 50 Voltage V 400 400 400 Current Nominal running current (RLA) Cooling A 6.50 12.00 12.60 Startin...
Page 6 - Options
3 2 • VRVII Systems • Outdoor Units 5 • Outdoor Units • VRV COOLING ONLY SYSTEM • RXQ5-10M9W1B 2 Options 4TW26671-1 NOTES All options are kits No Item RXQ5M RXQ8,10M 1 COOL/HEAT SELECTOR KRC19-26A 2 FIXING BOX KJB111A 3 REFNET HEADER KHRQ22M29H KHRQ22M29H 4 REFNET JOINT KHRQ22M20T KHRQ22M20TKHRQ22M2...
Page 7 - Capacity tables; - 1 Cooling capacity tables
• Outdoor Units • VRV COOLING ONLY SYSTEM • RXQ5-10M9W1B 3 • VRVII Systems • Outdoor Units 6 3 Capacity tables 3 - 1 Cooling capacity tables 5HP TC: Total capacity: kW ; PI: Power input: kW (Comp. + Outdoor fan motor) Combination (%) Capacity index Outdoor air temp. CDB Indoor air temperature: C...
Page 8 - - 1 Cooling capacity tables
3 3 • VRVII Systems • Outdoor Units 7 • Outdoor Units • VRV COOLING ONLY SYSTEM • RXQ5-10M9W1B 3 Capacity tables 3 - 1 Cooling capacity tables 5HP NOTES 1 The above table shows the average value of conditions which may occur. TC: Total capacity: kW ; PI: Power input: kW (Comp. + Outdoor fan motor) C...
Page 13 - Capacity correction factor
• Outdoor Units • VRV COOLING ONLY SYSTEM • RXQ5-10M9W1B 4 • VRVII Systems • Outdoor Units 12 4 Capacity correction factor RX(Y)Q5M • Rate of change in cooling capacity • Rate of change in heating capacity 3D048204A NOTES 1 These figures illustrate the rate of change in capacity of a standard indoor...
Page 16 - Dimensional drawing & centre of gravity; - 1 Dimensional drawing
3 5 • VRVII Systems • Outdoor Units 15 • Outdoor Units • VRV COOLING ONLY SYSTEM • RXQ5-10M9W1B 5 Dimensional drawing & centre of gravity 5 - 1 Dimensional drawing RX(Y)Q5M 3D047970 4-15x22.5-mm-Oblong holes (Foundation bolt hole) 722~737 (Pitch of foundation bolt holes) 497 Pitch of foundation ...
Page 17 - - 1 Dimensional drawing
• Outdoor Units • VRV COOLING ONLY SYSTEM • RXQ5-10M9W1B 7 5 • VRVII Systems • Outdoor Units 16 5 Dimensional drawing & centre of gravity 5 - 1 Dimensional drawing RX(Y)Q5M 3D041016A 383 765 100 635 1 8 Parts No. Part name Remark 1 Central drain pan kit KWC26B160 RX(Y)Q8, 10M 3D041017B 383 765 1...
Page 18 - - 2 Centre of gravity
3 5 • VRVII Systems • Outdoor Units 17 • Outdoor Units • VRV COOLING ONLY SYSTEM • RXQ5-10M9W1B 5 Dimensional drawing & centre of gravity 5 - 2 Centre of gravity RX(Y)Q5M 4D048181 256 310 Center of foundationbolt hole Center of foundationbolt hole Center of foundationbolt hole Center of foundati...
Page 19 - - 2 Centre of gravity
• Outdoor Units • VRV COOLING ONLY SYSTEM • RXQ5-10M9W1B 5 • VRVII Systems • Outdoor Units 18 5 Dimensional drawing & centre of gravity 5 - 2 Centre of gravity RX(Y)Q8, 10M 4D048182A 401 337 Center of foundationbolt hole Center of foundationbolt hole Center of foundationbolt hole Center of found...
Page 20 - Piping diagram
3 6 • VRVII Systems • Outdoor Units 19 • Outdoor Units • VRV COOLING ONLY SYSTEM • RXQ5-10M9W1B 6 Piping diagram RXQ5M 4TW26645-1 Solenoid valve Fan SV M Heat exchanger High pressure sensor High pressure switch INV Compressor Cappillary tube Oil separator Low pressure sensor Stop valve (With service...
Page 22 - Wiring diagram
3 7 • VRVII Systems • Outdoor Units 21 • Outdoor Units • VRV COOLING ONLY SYSTEM • RXQ5-10M9W1B 7 Wiring diagram 7 - 1 Wiring diagram RXQ5M9W1B 2TW25876-1 Power supply 400V 3N~50Hz 5 HP In-out Out-out (Note 2) F1 F2 F1 X1M ON OFF ON OFF F2 Indoor (F1)(F2) (Note 3) Outdoor (F1)(F2) (Note 3 ) Front la...
Page 23 - - 1 Wiring diagram
• Outdoor Units • VRV COOLING ONLY SYSTEM • RXQ5-10M9W1B 7 • VRVII Systems • Outdoor Units 22 7 Wiring diagram 7 - 1 Wiring diagram RXYQ8,10M9W1B 2TW26186-1 Power supply 400V 3N~50Hz 8 - 10 HP In-out Out-out (Note 2) F1 X1M ON OFF ON OFF XXX = Color of PCB connectorYYY = (Marked) color of wire conne...
Page 24 - - 2 External connection diagram
3 7 • VRVII Systems • Outdoor Units 23 • Outdoor Units • VRV COOLING ONLY SYSTEM • RXQ5-10M9W1B 7 Wiring diagram 7 - 2 External connection diagram RXQ-M 3D040746F POWER SUPPLY L1 L2 L3 N MAIN SWITCH L1 L2 L3 N SWITCH FUSE OUTDOOR UNITS 2 wires cable (transmission line) 2 wires cable (transmission li...
Page 25 - Sound level; - 1 Sound pressure spectrums
• Outdoor Units • VRV COOLING ONLY SYSTEM • RXQ5-10M9W1B 8 • VRVII Systems • Outdoor Units 24 8 Sound level 8 - 1 Sound pressure spectrums NOTES 1 Data is valid at free field condition (Measured in a semi-anachoic room). 2 dBA = A-weighted sound pressure level. (A-scale according to IEC) 3 Reference...
Page 26 - - 2 Sound power spectrums
3 8 • VRVII Systems • Outdoor Units 25 • Outdoor Units • VRV COOLING ONLY SYSTEM • RXQ5-10M9W1B 8 Sound level 8 - 2 Sound power spectrums NOTES 1 dBA = A-weighted sound power level. (A-scale according to IEC) 2 Reference acoustic intensity 0dB = 10E-6 µ W/m 2 . 3 Measured according to ISO 3744. RX(Y...
Page 27 - Installation
• Outdoor Units • VRV COOLING ONLY SYSTEM • RXQ5-10M9W1B 9 • VRVII Systems • Outdoor Units 26 9 Installation 9 - 1 Service space RXQ-M 3D040335D For single unit installation < Pattern1 > 300 or more < Front > 500 or more 10 or more 10 or more 100 or more < Front > 500 or more 300 o...
Page 28 - - 2 Fixation and foundation of units
3 9 • VRVII Systems • Outdoor Units 27 • Outdoor Units • VRV COOLING ONLY SYSTEM • RXQ5-10M9W1B 9 Installation 9 - 2 Fixation and foundation of units 3D040102D Y ditch Except 5HP Modeles A 100 A 160 A 160 100 50 50 ø100 80 80 80 60° B X X 75 929 729 100 When building a foundation on the ground Y dit...
Page 29 - - 3 Refrigerant pipe selection
• Outdoor Units • VRV COOLING ONLY SYSTEM • RXQ5-10M9W1B 9 • VRVII Systems • Outdoor Units 28 9 Installation 9 - 3 Refrigerant pipe selection E xam ple of conn ection (Con ne ction of 8 ind oo r units Heat pu m p syste m) Branc h with refne t j o int Br anc h wit h ref net j o int and re fne t heade...
Page 30 - - 3 Refrigerant pipe selection
3 9 • VRVII Systems • Outdoor Units 29 • Outdoor Units • VRV COOLING ONLY SYSTEM • RXQ5-10M9W1B 9 Installation 9 - 3 Refrigerant pipe selection Pi pe si z e s el e ct io n F o r an out do or un it m u lt i i n st al la ti o n (R XYQ 18 ~4 8M 9W 1B ), m ak e the set ti ngs in acco rd an ce wi th t h ...
Page 31 - Operation range; Cooling
• Outdoor Units • VRV COOLING ONLY SYSTEM • RXQ5-10M9W1B 10 • VRVII Systems • Outdoor Units 30 10 Operation range RXQ-M 4TW25873-1A NOTES 1 These figures assume the following operating conditions:Indoor and outdoor units:Equivalent pipe length: 7.5mLevel difference: 0m 2 Depending on operation and i...
Page 32 - Systems
Systems ISO14001 assures an effective environmental management system in order to help protect human•health•and the environment from the potential impact of our activities, products and services and to assist in maintaining and improving the quality of the•environment. Daikin Europe N.V. is approved...