Campbell Hausfeld WF2034 - Manual

Campbell Hausfeld WF2034

Campbell Hausfeld WF2034 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
Page: / 24

Table of Contents:

  • Page 2 – DANGER; General Safety
  • Page 3 – Ground Clamp; ADDITIONAL SAFETY STANDARDS; from American; Safety and Health Standards; WARNING
  • Page 4 – Flux Core Wire Installation; Do not cut; Turn; CAUTION; Contact Tip Markings; Operation
  • Page 5 – Consumable and Wear Parts; for replacement parts; General; HEAT SETTING
  • Page 6 – Wire Feed Arc Welder; Welding Guidelines; WELDING POSITIONS; TRAVEL ANGLE
  • Page 7 – PUSH VS PULL TECHNIQUE; Supply Cable Replacement
  • Page 8 – Troubleshooting Chart - Welder; Troubleshooting Chart - Welds
  • Page 11 – Glossary of Welding Terms
  • Page 12 – Notes
  • Page 13 – Manual de Instrucciones y Lista de Repuestos; Para desempacar; Componentes y Controles; Pinza de tierra; tomacorrientes de 115 voltios.; Control de nivel; PRECAUCION; ADVERTENCIA; PELIGRO; Bajo; Descripción; © 2000 Campbell Hausfeld / Scott Fetzer
  • Page 14 – Ésto le indica cualquier; Soldadora Con Arco Con Alambre Continuo
  • Page 15 – b. Cerciórese de que el área de; —NFPA; Instalación
  • Page 16 – No corte el alambre todavía; INSTALACION DEL ALAMBRE; mm; Funcionamiento; Ensamblaje
  • Page 17 – Comuníquese con el; Espesor
  • Page 18 – Instrucciones para Soldar; ANGULO DE DESPLAZAMIENTO
  • Page 20 – DIAGNOSTICO; Diagóstico de Averías-Soldadora; Diagóstico de Averías-Soldadura
  • Page 22 – Para ordenar repuestos, comuníquese con el distribuidor
  • Page 23 – Glosario de terminología usada por soldadores
  • Page 24 – Notas
Loading the manual

Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described.
Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or
property damage! Retain instructions for future reference.

IN970300AV 11/00

Operating Instructions & Parts Manual

Model WF2034

Wire Feed
Arc Welder

B U I L T T O L A S T

TM

The Campbell Hausfeld WF2034 is a 70
amp, single phase 115 volt input, wire
feed arc welding machine equipped with
infinite wire speed control to accurately
select the proper wire feed rate needed
for various welding conditions. Internal
components are thermostatically
protected.

This welding system is designed for use
with Flux Core Arc Welding (Gasless)
only. As delivered from the factory, this
welder can weld with .030” (.8mm) to
.035” (.9mm) diameter flux-cored wire.
A starter spool of .035” flux-cored wire
is included.

Unpacking

Some welder components may be
found in the wire feed compartment.

When unpacking, inspect carefully for
any damage that may have occurred
during transit. Report any damaged or
missing items by calling (800) 746-5641.

Circuit Requirements

This equipment
requires a

dedicated 115 volt circuit. Refer to the
following chart for the correct circuit
breaker or fuse rating. Do not run
other appliances, lights, or tools on
this circuit while operating this
equipment. Extension cords are not
recommended. Blown fuses and tripped
circuit breakers can result from failure
to comply with this recommendation.

!

CAUTION

Components and Controls

1.

Ground Clamp

- connect to work

piece.

2.

Wire Feed Gun

3.

Power Cord

- plug into 115 volt

outlet.

4.

On/Off Switch

5.

Heat Selector

- Selects welding

power (high/low).

6.

Infinite Wire Speed Control

-

turn clockwise to increase wire
speed and counterclockwise to
decrease wire speed.

Heat

Circuit Breaker or

Selector

Slow Blow Fuse

Danger means a
hazard that will

cause death or serious injury if the
warning is ignored.

Warning means a
hazard that could

cause death or serious injury if the
warning is ignored.

Caution means a
hazard that may

cause minor or moderate injury if the
warning is ignored. It also may mean a
hazard that will only cause damage to
property.

NOTE:

Note means any additional

information pertaining to the product
or its proper usage.

!

CAUTION

!

WARNING

!

DANGER

Low 15

amp

High 20

amp

Q

U

A

L

IT

Y

AS

S

U

RANC

E

P

ROG

RA

M

Need

Assistance?

Call Us First!

1-800-746-5641

Description

General Safety

2

1

3

4

5

6

Figure 1

© 2000 Campbell Hausfeld / Scott Fetzer

For parts, product & service information

visit

www.chpower.com

Farmhand 85

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - DANGER; General Safety

2 Wire Feed Arc Welder Always keep a fireextinguisher accessiblewhile performing arcwelding operations. ● Before starting or servicing anyelectric arc welder, read andunderstand all instructions. Failureto follow safety precautions orinstructions can cause equipmentdamage and/or serious personalinju...

Page 3 - Ground Clamp; ADDITIONAL SAFETY STANDARDS; from American; Safety and Health Standards; WARNING

LOCATION Selecting the proper location cansignificantly increase performance,reliability and life of the arc welder. ● For best results locate the welder inan environment that is clean anddry. ● Store flux core wire in a clean, drylocation with low humidity topreserve the flux wire coating. ● The us...

Page 4 - Flux Core Wire Installation; Do not cut; Turn; CAUTION; Contact Tip Markings; Operation

Flux Core Wire Installation Welding poweris applied to the output terminals, feed roll, groundclamp, gun cable connection andwelding wire even when the gunswitch is not activated. Do not touchthese parts when the welding machineis on. NOTE: Before installing welding wire, be sure that the diameter o...

Other Campbell Hausfeld Models

All Campbell Hausfeld Other