Campbell Hausfeld HV2500 - Manual

Campbell Hausfeld HV2500

Campbell Hausfeld HV2500 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
Page: / 16

Table of Contents:

  • Page 2 – General Safety; CAUTION; WARNING; DANGER; DANGER; For Information About
  • Page 3 – Maintenance; Troubleshooting Chart; Replacement Parts List; For Information About This Product; Accessories
  • Page 4 – Limited Warranty
  • Page 5 – Instructions D’Utilisation Et Manuel De Pièces; Turbine HVLP; Description; PIÉCES DÉTACHÉES; MÉMENTO: Gardez votre preuve datée d'achat à fin de la garantie!
  • Page 6 – Généralités Sur La Sécurité; ATTENTION; ATTENTION; Pour Des Informations
  • Page 7 – Pour Des Informations Concernant Ce Produit,; Entretien; Liste De Pièces De Rechange; Accessoires
  • Page 8 – Garantie Limitée
  • Page 9 – Manual de Peças e de Instruções de Operação; Turbina HVLP; Descrição; COMPONENTES
  • Page 10 – Segurança Geral; CUIDADO; INSTRUÇÕES DE ATERRAMENTO; PERIGO; CUIDADO
  • Page 11 – Manutenção; Tabela de Solução de Problemas; Lista de Peças de Reposição; Para obter informações sobre este produto; Acessórios
  • Page 12 – Garantia Limitada
  • Page 13 – Manual de Instrucciones & Lista de Partes; Descripción; Adjúntela a este manual o archívela en lugar seguro.
  • Page 14 – PRECAUCION; PELIGRO; PRECAUCION; Para mayor información
  • Page 15 – Mantenimiento; Guía de Diagnóstico de averías; Lista De Repuestos; Paquete de filtros; Para mayor información sobre este producto, comuníquese con; Accesorios
  • Page 16 – Garantía Limitada
Loading the manual

Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described.
Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or
property damage! Retain instructions for future reference.

IN206600AV 2/03

Operating Instructions & Parts Manual

HV2000 and HV3000 Series

HVLP
Turbine

B U I L T T O L A S T

Description

Campbell Hausfeld HVLP turbines are
designed to generate a High Volume of
Low Pressure air for operating HVLP
spray guns. These turbines operate
differently than air compressors
because turbines do not require an air
tank to hold compressed air. Since
there is no compression of air, HVLP
turbines do not create condensation in
the air hoses as compressors often do.
Consequently, the project is not at risk
of condensation contaminating the
coating material. The air generated by
the turbine is generally warm due to
the air working in the turbine. The
warm air can be a benefit for
accelerating drying in less than ideal
weather conditions and for drying the
spray gun components. HVLP turbines
are portable, can be plugged into
standard outlets and operate and
sound similar to shop-vacs.

Unpacking

When unpacking the unit, inspect
carefully for any damage that may
have occurred during transit. Make
sure any loose fittings, bolts, etc., are
tightened before putting sprayer into
service. Each unit has been tested
before shipment. Do not readjust or
modify the turbine components.

Specifications

MODEL HV2000

CFM . . . . . . . .54 CFM at turbine outlet
Operating Pressure . . . . . . . .4 PSI Max.
Motor Type . . . . . . .Brush type, 2 stage,

. . . . . . . . . . . . . . . . . . . . . . . .Tangential

Hose Length . . . . . . .15 ft. (30 ft. Max.)
Transfer Efficiency . . . . . . . . .86% Max.
Weight . . . . . . . . . . . . . . . . . .15 Pounds
Voltage . . . . . . . . . . . . .120V, 10.1 Amp
Stub Hose . . . . . . . . . . . . . . . . . . . . . .No
Storage Compartment . . . . . . . . . . .Yes

MODEL HV2500

CFM . . . . . . . .58 CFM at turbine outlet
Operating Pressure . . . . . . . .5 PSI Max.
Motor Type . . . . . . .Brush type, 2 stage,

. . . . . . . . . . . . . . . . . . . . . . . .Tangential

Hose Length . . . . . . .25 ft. (40 ft. Max.)
Transfer Efficiency . . . . . . . . .86% Max.
Weight . . . . . . . . . . . . . . . . . .26 Pounds
Voltage . . . . . . . . . . . . . .120V, 11 Amp
Stub Hose . . . . . . . . . . . . . . . . . . . . . .Yes
Storage Compartment . . . . . . . . . . .Yes

MODEL HV3000

CFM . . . . . . . .65 CFM at turbine outlet
Operating Pressure . . . . . . . .6 PSI Max.
Motor Type . . . . . . .Brush type, 3 stage,

. . . . . . . . . . . . . . . . . . . . . . . .Tangential

Hose Length . . . . . . .25 ft. (50 ft. Max.)
Transfer Efficiency . . . . . . . . .86% Max.
Weight . . . . . . . . . . . . . . . . . .28 Pounds
Voltage . . . . . . . . . . . . .120V, 13.8 Amp
Stub Hose . . . . . . . . . . . . . . . . . . . . . .Yes
Storage Compartment . . . . . . . . . . .Yes

COMPONENTS

(1) Turbine
(1) Hose and quick connect fitting

assemble and clean the unit (storage
compartment)

(1) Wrench - the only tool needed to

assemble and clean the unit (storage
compartment)

(1) Viscosity stick storage compartment)
(1) Cleaning brush ( storage compartment)

Attention: Campbell Hausfeld recommends that servicing other than that shown in the instruction manual should be
performed by an authorized service facility. NOT INTENDED FOR CONTINUOUS USE.

© 2003 Campbell Hausfeld/Scott Fetzer

For parts, product & service information

visit

www.chpower.com

See Warranty on page 4 for important information about commercial use of this product.

REMINDER: Keep your dated proof of purchase for warranty purposes! Attach it to this manual or file it for safekeeping.

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - General Safety; CAUTION; WARNING; DANGER; DANGER; For Information About

2 Operating Instructions and Parts Manual General Safety Danger means ahazard that will cause death or serious injury if thewarning is ignored. Warning means ahazard that could cause death or serious injury if thewarning is ignored. Caution means ahazard that may cause minor or moderate injury if th...

Page 3 - Maintenance; Troubleshooting Chart; Replacement Parts List; For Information About This Product; Accessories

3 Operating Instructions and Parts Manual Maintenance Be sure the air filter is clean. A dirty airfilter restricts air flow and can cause themotor to overheat. IMPORTANT: Keep the unit at the maximum distance from the spray areato extend filter life. Figure 3 Troubleshooting Chart Symptom Possible C...

Page 4 - Limited Warranty

4 Operating Instructions and Parts Manual Limited Warranty 1. DURATION: From the date of purchase by the original purchaser as follows: Standard Duty Paint Application Systems and all Paint Application Accessories - 1 year, Serious Duty Paint Application Systems - 3 years, Extreme Duty Paint Applica...

Other Campbell Hausfeld Models

All Campbell Hausfeld Other