Page 3 - causing personal injury, loss of life or property damage.
All installations and services must be performed by qualified service personnel. : If you do not follow these instructions exactly, a fire or explosion may result causing personal injury, loss of life or property damage. : NEVER use gasoline or a mixture of oil and gasoline to start the burner or fu...
Page 8 - This furnace is not to be used as a construction heater.; Combustible material:
All installations and services must be performed by qualified service personnel. II. GENERAL INSTRUCTIONS AND CLEARANCES NOTE: READ THIS SECTION BEFORE STARTING INSTALLATION 1. The selection of a furnace heating capacity for a proposed installation should be based on a heat loss calculation made acc...
Page 9 - CLOSET ALCOVE
All installations and services must be performed by qualified service personnel. b. Non-combustible material: “...material that is not capable of being ignited and burned; such as material consisting entirely of, or a combination of, steel, iron, brick, concrete, slate, asbestos, glass, and plaster....
Page 10 - III. FURNACE SPECIFICATIONS; HEATING
All installations and services must be performed by qualified service personnel. III. FURNACE SPECIFICATIONS MODEL OMD-70 GMD-85 HEAT INPUT RATE (BTUH) 85,000 85,000 HEATING CAPACITY (BTUH) 71,000 69,700 BURNER NOZZLE (GPH X ANGLE, HOLLOW CONE) 0.65X80A ------- BURNER ORIFICE-NAT. GAS --------- #17 ...
Page 11 - P265 FEP; BLOWER DATA
All installations and services must be performed by qualified service personnel. BURNER DATA OMD-70 GMD-85 MANUFACTURER: R.W. BECKETT CORP. WAYNE COMBUSTION SYSTEMS MODEL: AFG P265 FEP AIR TUBE LENGTH (IN.): 3-5/8 3-5/8 HEAD DESIGN: F-3 -------- REFRACTORY TYPE: MHC (FIBER) MHC (FIBER) OIL PUMP PRES...
Page 13 - must comply with the requirements of this manual.; Figure
All installations and services must be performed by qualified service personnel. 4. This furnace is U.L. listed for closet, alcove or freestanding applications. All applications must comply with the requirements of this manual. Combustible Floor Base Model: 70-BASE Figure 1A. Cottage Base Model: 01C...
Page 15 - COMBUSTION AIR; for further details regarding combustion air requirements.
All installations and services must be performed by qualified service personnel. If the combustion air passageway cannot terminate outside of the skirting or enclosure, a permanent opening with a minimum of 50 square inches of unobstructed infiltration (free area) for ventilation air must be provide...
Page 17 - must; be provided to the front of the unit.
All installations and services must be performed by qualified service personnel. E. ALCOVE INSTALLATION In this application, a minimum of 18 inches of clearance must be provided to the front of the unit. Refer to Figure 4. Alcove installations must use the No. 70 mobile home base. Note – access to d...
Page 19 - Combustion air cannot be drawn from the occupied space of the
All installations and services must be performed by qualified service personnel. The preferred location of the outside combustion air intake termination (e.g. an optional stainless steel intake hood, part no.370183) is through the side of the structure, skirting or enclosure. An alternate terminatio...
Page 22 - Do not run the oil pump dry for more than five minutes.; Avoid running tubing against any type of
All installations and services must be performed by qualified service personnel. : The furnace and its gas valve must be disconnected from the gas supply during pressure testing of the gas supply system at pressures in excess of 1/2 PSIG (13.9 inches W.G.). The furnace can be isolated from the gas s...
Page 26 - wires to the thermostat.; BLOWER CONTROLLER INFORMATION FOR PSC MOTOR
All installations and services must be performed by qualified service personnel. Once the furnace is installed, check the thermostat heat anticipator the proper nominal setting. a. Connect a multimeter, capable of reading milliamps (mA), in series with the low voltage wires to the thermostat. b. Inc...
Page 29 - PSC TROUBLE SHOOTING; DIAGNOSTIC FEATURES
All installations and services must be performed by qualified service personnel. DIP SWITCH 2 SECTION STATE BLOWER DELAY TIMES 1 2 3 4 ON - SEC OFF - MIN OFF OFF 30 FACTORY SETTING ON OFF 60 OFF ON 120 ON ON 240 OFF OFF 2 FACTORY SETTING ON OFF 4 OFF ON 6 ON ON 8 Table 11: ON and OFF Blower Delay Ti...
Page 30 - DIAGRAM
All installations and services must be performed by qualified service personnel. 5. WIRING DIAGRAM 29
Page 31 - K. BURNER INSTALLATION; burner oil pump through the base of the unit.
All installations and services must be performed by qualified service personnel. K. BURNER INSTALLATION The burner mounts to the furnace on three mounting bolt studs, located on the burner mounting plate, in the lower portion of the vestibule, directly in front of the heat exchanger. The burner inse...
Page 34 - BURNER COMBUSTION PARAMETERS
All installations and services must be performed by qualified service personnel. range is between 70°F to 100°F. A lower temperature rise usually results in a higher system efficiency. : If the temperature rise exceeds 100°F, the heat exchanger may fail, voiding the heat exchanger warranty resulting...
Page 35 - V. DEALER MAINTENANCE; procedures and precautions.
All installations and services must be performed by qualified service personnel. V. DEALER MAINTENANCE THIS SECTION IS ONLY TO BE PERFORMED BY TRAINED, QUALIFIED SERVICE PERSONNEL, AND NOT BY THE FURNACE OWNER. A. TROUBLESHOOTING Note: Check diagnostic code through view port prior to removing doors....
Page 36 - OMD/GMD TROUBLESHOOTING FLOWCHART; Note: Check diagnostic code through view port
All installations and services must be performed by qualified service personnel. Yes Set thermostat subbase to "HEAT" Does thermostat make contact? Does a "call for heat" initiate an ignition cycle? No Yes Is room temperature above 90 deg. F? Yes Wait for room air to cool. Yes Turn t...
Page 42 - : Do not start burner unless blower door is; D. CLEANING OR REPLACING FLUE PIPES
All installations and services must be performed by qualified service personnel. 4. With access to the inside of the heat exchanger through the burner cleanout openings and the vent pipe connection, it is now possible to use a long, flexible wire brush and an industrial-type vacuum cleaner to remove...
Page 43 - be cleaned or replaced; be replaced
All installations and services must be performed by qualified service personnel. Flue pipes should be inspected during the annual maintenance check-up or during each subsequent service call. Check all flue pipes for restrictions due to soot, or carbon build-up, as well as foreign matter, or any mate...
Page 44 - VI. USER INFORMATION SECTION; tossing burning papers or other material into the furnace.
All installations and services must be performed by qualified service personnel. VI. USER INFORMATION SECTION A. WARNINGS AND CAUTIONS: : If you suspect there is a problem with the furnace, pertaining to the venting system or any other related problem, immediately contact a qualified service agency....
Page 45 - B. COMPONENT LOCATIONS
All installations and services must be performed by qualified service personnel. B. COMPONENT LOCATIONS The following diagram shows a typical furnace installation and typical position of the components referenced in these instructions. Figure 9. C. INSPECTION AREAS IMPORTANT: For safe operation it i...
Page 46 - INSTALLATION / SERVICE
All installations and services must be performed by qualified service personnel. 2. EXTERIOR OF FURNACES: The furnace exterior should be inspected for signs of excessive heat such as discoloration of materials or damage from rust or corrosion. 3. VENT CONNECTOR: The furnace vent pipe should be inspe...
Page 47 - APPENDIX A. REPLACEMENT PARTS LIST
All installations and services must be performed by qualified service personnel. APPENDIX A. REPLACEMENT PARTS LIST 46