Thermo Pride CDX1-75N - Manual

Thermo Pride CDX1-75N

Thermo Pride CDX1-75N – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
29 Page 29
30 Page 30
31 Page 31
32 Page 32
33 Page 33
34 Page 34
35 Page 35
36 Page 36
37 Page 37
38 Page 38
39 Page 39
40 Page 40
41 Page 41
42 Page 42
43 Page 43
44 Page 44
45 Page 45
46 Page 46
47 Page 47
48 Page 48
49 Page 49
50 Page 50
51 Page 51
52 Page 52
53 Page 53
54 Page 54
55 Page 55
56 Page 56
57 Page 57
58 Page 58
59 Page 59
Page: / 59

Table of Contents:

  • Page 2 – I. SAFETY INFORMATION
  • Page 3 – ii
  • Page 5 – iv
  • Page 13 – B1. CDX1 HORIZONTAL APPLICATION
  • Page 14 – Figure 1; formed by the intersection of
  • Page 15 – MAXIMUM VENT LENGTH; VENT SIZE
  • Page 16 – The drain tee supplied with CHX1/CDX1 furnaces count as 1 elbow.; E. SIDEWALL VENTING
  • Page 17 – three feet from an inside corner of an L-shaped structure.
  • Page 18 – with a single exhaust pipe. This will be a non-direct vent
  • Page 19 – Figure 5
  • Page 20 – as well as a list of the parts that will be needed to install each.; Figure 6
  • Page 21 – Figure 7
  • Page 22 – Figure 8
  • Page 23 – Figure 9
  • Page 25 – H. CONNECTING THE FURNACE TO ROOF VENT/AIR TERMINATIONS; system during the furnace off cycle.
  • Page 27 – Connect the drain hose from; to the uncapped bottom drain from; step b; step a; with the existing cap removed in; step b
  • Page 32 – black; line lead and the common leg to the white line lead in
  • Page 33 – BLOWER AND CONTROL PANEL WIRING
  • Page 41 – Allow the burner to; operate for at least 3 minutes; before taking gas pressure readings.; input rate by measuring burner manifold pressure, skip to step 12; measuring the; input rate using a gas meter, proceed to step 9; ççè; specified low fire manifold pressure.
  • Page 44 – This furnace is designed; not; operating properly.; The main burner must light reliably under all conditions.
  • Page 45 – TABLE 6 - CONVERTING GAS FLOW RATE
  • Page 46 – C. FURNACE CHECKOUT PROCEDURE; burner should shut off.
  • Page 48 – : Power must be disconnected before servicing.
  • Page 54 – Appendix –A Replacement Parts List
  • Page 58 – Appendix – B W iring Diagrams
Loading the manual

MG-1010

ECN4470-MA

TWO STAGE CONDENSING GAS FURNACE

INSTALLATION AND OPERATION MANUAL

MODELS:

FOR USE WITH NATURAL GAS OR LP GAS (PROPANE)

CHX1-75N

CDX1-75N

CHX1-100N

CDX1-100N

CHX1-125N

CDX1-125N

:

IF YOU DO NOT FOLLOW THE SAFETY PRECAUTIONS BELOW AND IN THIS

MANUAL, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL
INJURY, OR LOSS OF LIFE.

DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS AND LIQUIDS IN THE
VICINITY OF THIS OR ANY OTHER APPLIANCE.

WHAT TO DO IF YOU SMELL GAS:

DO NOT TRY TO LIGHT ANY APPLIANCE.

DO NOT TOUCH ANY ELECTRICAL SWITCH; DO NOT USE ANY PHONE IN YOUR BUILDING.

LEAVE THE BUILDING IMMEDIATELY.

IMMEDIATELY CALL YOUR GAS SUPPLIER FROM A NEIGHBOR’S PHONE. FOLLOW THE GAS
SUPPLIER’S INSTRUCTIONS.

IF YOU CANNOT REACH YOUR GAS SUPPLIER; CALL THE FIRE DEPARTMENT.

INSTALLATION AND SERVICE MUST BE PERFORMED BY A QUALIFIED INSTALLER, SERVICE
AGENCY OR THE GAS SUPPLIER. (REFERRED TO IN THESE INSTRUCTIONS AS A QUALIFIED
HEATING CONTRACTOR).

PLEASE READ THESE INSTRUCTIONS PRIOR TO INSTALLATION, INITIAL FIRING, AND BEFORE
PERFORMING ANY SERVICE OR MAINTENANCE. THESE INSTRUCTIONS MUST BE LEFT W ITH
THE HOMEOW NER AND SHOULD BE RETAINED FOR FUTURE REFERENCE BY QUALIFIED
SERVICE PERSONNEL.

THERMO PRODUCTS, LLC.

BOX

217

NORTH

JUDSON,

IN

46366

PHONE: (574) 896-2133

MADE IN USA

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - I. SAFETY INFORMATION

All installations and services must be performed by qualified service personnel. i I. SAFETY INFORMATION This and the following page contain reproductions of the various warning and instruction labels placed on the Thermo Pride Two Stage Condensing Gas Furnaces. Please read and comply with the conte...

Page 3 - ii

All installations and services must be performed by qualified service personnel. ii This and the previous page contain reproductions of the various warning and instruction labels placed on the Thermo Pride Two Stage Condensing Gas Furnaces. Please read and comply with the contents of these labels. T...

Page 5 - iv

All installations and services must be performed by qualified service personnel. iv : Personal injury or property damage could result from repair or service of this furnace by anyone other than a qualified heating contractor. Only the homeowner/user routine maintenance described in the Users Informa...

Other Thermo Pride Models