Thermo Pride CMA3-50D36N - Manual

Thermo Pride CMA3-50D36N

Thermo Pride CMA3-50D36N – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
29 Page 29
30 Page 30
31 Page 31
32 Page 32
33 Page 33
34 Page 34
35 Page 35
36 Page 36
37 Page 37
38 Page 38
39 Page 39
40 Page 40
41 Page 41
42 Page 42
43 Page 43
44 Page 44
45 Page 45
46 Page 46
47 Page 47
48 Page 48
49 Page 49
50 Page 50
51 Page 51
52 Page 52
53 Page 53
54 Page 54
55 Page 55
56 Page 56
57 Page 57
58 Page 58
59 Page 59
60 Page 60
61 Page 61
62 Page 62
63 Page 63
64 Page 64
65 Page 65
Page: / 65

Table of Contents:

  • Page 3 – I. SAFETY INFORMATION
  • Page 9 – II. FURNACE SPECIFICATIONS
  • Page 14 – COMBUSTIBLE MATERIAL:; CLOSET; Table 1
  • Page 15 – connect a ducted return air system directly to the furnace.
  • Page 16 – Coil cabinet cannot be utilized as a cottage base.
  • Page 17 – B. BASE INSTALLATION – CMA3 models only
  • Page 19 – In this application, a minimum of 18 inches of clearance; must; be provided to the; The return air opening into the closet is to have a; minimum
  • Page 20 – Do not obstruct any return air openings, including the return
  • Page 22 – The furnace and its gas valve must be disconnected from the; F. GENERAL VENTING REQUIREMENTS; All CMA/CMC furnaces must be
  • Page 23 – MAXIMUM VENT LENGTH; VENT SIZE; Table 2; The CMA/CMC furnace models are vented through the roof.
  • Page 24 – G. CONNECTING THE EXHAUST VENT AND COMBUSTION AIR INTAKE
  • Page 25 – The furnace model series CMA/CMC may be vented either; For sidewall instructions, continue to the
  • Page 26 – a. The exhaust vent termination must be installed in the same
  • Page 28 – where wetting of components by condensate, or water vapor, could; Building Features
  • Page 29 – Vent Terminal Location Guidelines; : Bushes, shrubs, or any vegetation that may restrict the flow of; I. Installation Of Outside Exhaust / Intake Terminations; passage
  • Page 30 – Follow instructions included with concentric vent kit AOPS7483.
  • Page 33 – c. Connect the “hot” wire to the black wire; black; The furnace must be grounded in accordance with local codes
  • Page 34 – The room thermostat should be installed 4 to 5 feet above; Electrical Wire; with the low voltage wires to the thermostat.
  • Page 35 – BLOWER MOTOR SPEED WIRING
  • Page 36 – COOLING UNIT
  • Page 46 – Seconds for one revolution
  • Page 47 – D. BURNER ADJUSTMENT
  • Page 48 – The CMA/CMC furnace models are direct vent design and do; E. SETTING TEMPERATURE RISE; F. If the outlet or supply duct
  • Page 49 – F. FURNACE CHECKOUT PROCEDURE; Remove blockage or reconnect blower motor and restore power.
  • Page 52 – CLEANING THE COIL AIR SIDE; The inducer motor mounting plate gasket and the collector box; D. HOUSE AIR BLOWER; Some motors are permanently lubricated; and should not be; See motor name plate for specific instructions.; E. RETURN AIR FILTER
  • Page 53 – FILTER MAINTENANCE PROCEDURE; Remind homeowner of importance of monthly filter inspections
  • Page 54 – The LED will also flash once at power-up.; : Power must be disconnected before servicing.
  • Page 60 – APPENDIX – A REPLACEMENT PARTS
  • Page 64 – APPENDIX – B WIRING DIAGRAMS
Loading the manual

GAS FIRED HIGH EFFICIENCY FURNACE

DOWNFLOW & DIRECT VENT (SEALED COMBUSTION)

MODELS:

CMA3-50D36N, CMA3-75D36N,
CMC1-50D36N, CMC1-75D36N,

CMC1-50DV3N, CMC1-75DV3N

INSTALLATION AND SERVICE MANUAL

For installation in:

1. Manufactured Homes

2. Modular Homes/Buildings

3. Site Constructed—Residential (Single Story Dwellings)

FOR YOUR SAFETY

Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or
any other appliance.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electrical switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone.

Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

:

If the information in these instructions is not followed exactly, a fire or explosion may

result causing property damage, personal injury, or loss of life.

: Improper installation, adjustment, alteration, service, or maintenance can cause injury or

property damage. Refer to this manual. For assistance or additional information, consult a qualified
installer, service agency, or fuel supplier.

: Do not use this appliance if any part has been underwater. Immediately call a qualified

service technician to inspect the appliance and to replace any part of the electrical or control system
that has been underwater.

PLEASE READ THESE INSTRUCTIONS PRIOR TO INSTALLATION, INITIAL FIRING, AND BEFORE PERFORMING
ANY SERVICE OR MAINTENANCE. THESE INSTRUCTIONS MUST BE LEFT WITH THE USER AND SHOULD BE
RETAINED FOR FUTURE REFERENCE BY QUALIFIED SERVICE PERSONNEL.

THERMO PRODUCTS, LLC.

POST OFFICE BOX 217

NORTH JUDSON, IN 46366

PHONE: (574) 896-2133

MG-517

ECN 5295-MA 140106

MADE IN USA

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 3 - I. SAFETY INFORMATION

All installations and services must be performed by qualified service personnel. I. SAFETY INFORMATION This and the following page contain reproductions of the various warning and instruction labels placed on the Thermo Pride Condensing Gas Furnaces. Please read and comply with the contents of these...

Page 9 - II. FURNACE SPECIFICATIONS

All installations and services must be performed by qualified service personnel. II. FURNACE SPECIFICATIONS MODEL CMA3-50D36 CMA3-75D36 INPUT IN BTUH 50,000 75,000 OUTPUT IN BTUH 48,000 72,000 MAIN ORIFICE-NAT. #42 MAIN ORIFICE-LP #54 GAS SUPPLY PRESSURE L.P. MINIMUM 11” IN.W.C. NAT. MINIMUM 4.5”IN....

Page 14 - COMBUSTIBLE MATERIAL:; CLOSET; Table 1

All installations and services must be performed by qualified service personnel. d. American National Standard (ANSI-C1/NFPA-70 Electric Code for all electrical field wiring. e. These gas-fired units have been investigated under standards ANSI Z 21.47 CAN/CGA Z223-2001 Central Furnace test standards...

Other Thermo Pride Models

All Thermo Pride Other