TABULAR DATA SHEET
Outdoor Split System Heat Pump 1.5 Thru 5 Tons
MODELS: THJD18* THRU 60
13 SEER – R-410A, 1 PHASE
All dimensions are in inches. They are subject to change without notice.
Certified dimensions will be provided upon request.
Physical and Electrical Data
MODEL
THJD18
S41S3
THJD24
S41S4
THJD30
S41S4
THJD36
S41S4
THJD42
S41S4
THJD48
S41S4
THJD60
S41S4
Unit Supply Voltage
208-230V, 1
60Hz
Normal Voltage Range
1
187 to 252
Minimum Circuit Ampacity
11.9
11.2
14.1
19.7
20.9
25.6
34.9
Max. Overcurrent Device Amps
2
20
15
20
30
35
45
60
Min. Overcurrent Device Amps
3
15
15
15
20
25
30
35
Compressor Type
Scroll
Recip
Recip
Recip
Recip
Recip
Scroll
Compressor
Amps
Rated Load
9.0
8.3
10.6
14.7
15.7
19.4
26.9
Locked Rotor
48.0
43.0
54.0
74.0
88.0
88.0
135.0
Crankcase Heater
No
Yes
Yes
Yes
Yes
Yes
No
Factory External Discharge Muffler
Yes
No
No
No
No
No
Yes
Factory External Check Valve
No
No
No
No
No
No
No
HS Kit Required with TXV
4
No
Yes
Yes
Yes
Yes
Yes*
No
Fan Motor Amps
Rated Load
0.70
0.80
0.80
1.3
1.3
1.3
1.3
Fan Diameter Inches
24
24
24
24
24
24
24
Fan Motor
Rated HP
1/10
1/8
1/8
1/4
1/4
1/4
1/4
Nominal RPM
825
1075
1075
850
850
850
850
Nominal CFM
2000
2900
3000
3800
3800
3600
3600
Coil
Face Area Sq. Ft.
15.7
18.3
21.0
23.6
23.6
23.6
23.6
Rows Deep
1
1
1
1
1
2
2
Fin / Inches
22
22
22
22
22
18
18
Liquid Line Set OD (Field Installed)
3/8
3/8
3/8
3/8
3/8
3/8
3/8
Vapor Line Set OD (Field Installed)
3/4
3/4
3/4
3/4
7/8
7/8
7/8
Unit Charge (Lbs. - Oz.)
5
6 - 6
9 - 6
9 - 0
10 - 0
9 - 10
14 - 12
13 - 13
Charge Per Foot, Oz.
0.62
0.62
0.62
0.62
0.67
0.67
0.67
Operating Weight Lbs.
172
194
206
218
218
285
284
* These models are shipped with a Hard Start Kit installed at the factory.
1. Rated in accordance with ANSI/AHRI Standard 110-2002, utilization range “A”.
2. Dual element fuses or HACR circuit breaker. Maximum allowable overcurrent protection.
3. Dual element fuses or HACR circuit breaker. Minimum recommended overcurrent protection.
4. See Hard Start Kit Accessory Installation Manual for Hard Start Kit part number for each model.
5. The Unit Charge is correct for the outdoor unit, matched indoor coil, and 15 feet of refrigerant tubing. For tubing lengths other than 15 feet, add
or subtract the amount of refrigerant, using the difference in length multiplied by the per foot value.
B
C
A
Unit
Model
Dimensions
(Inches)
Refrigerant Connection
Service Valve Size
A
1
1. Including Fan Guard.
B
C
Liquid
Vapor
18
28
34
34
3/8”
3/4”
24
32
34
34
30
36
34
34
36
40
34
34
42
40
34
34
7/8”
48
40
34
34
60
40
34
34
MAC-220
ECN 5287-MA 121005