Page 2 - Instructions for the installer; INSTRUCTIONS FOR SAFE AND PROPER USE
Instructions for the installer 4 1. INSTRUCTIONS FOR SAFE AND PROPER USE THIS MANUAL IS AN INTEGRAL PART OF THE APPLIANCE AND THEREFORE MUST BE KEPT IN ITS ENTIRETY AND IN AN ACCESSIBLE PLACE FOR THE WHOLE WORKING LIFE OF THE COOKING HOB. WE ADVISE READING THIS MANUAL AND ALL THE INSTRUCTIONS THEREI...
Page 4 - INSTALLATION OF THE APPLIANCE; be carried out by a competent tradesman.; Fixing the conventional built-in model to the structure
Instructions for the installer 6 2. INSTALLATION OF THE APPLIANCE The following operation requires building and/or carpentry work so must be carried out by a competent tradesman. Installation can be carried out on various materials such as masonry, metal, solid wood or plastic laminated wood as long...
Page 5 - Attachment to support structure, flush-mounting model; Apply a layer of “waterproof primer” to the milled surface.
Instructions for the installer 7 2.2 Attachment to support structure, flush-mounting model Create an opening with the dimensions shown in the figure in the work surface, observing a minimum distance of 50 mm from the rear edge. The lower part of the protective cover must be fully accessible when the...
Page 6 - Caution: surface temperature underneath may exceed 125 degrees C.
Instructions for the installer 8 Overall dimensions: location of gas and electrical connection points (all measures in mm). Caution: surface temperature underneath may exceed 125 degrees C. To avoid a hazard, under-bench access must be restricted. Refer to installation instruction IMPORTANT: when in...
Page 7 - Clearance above and around domestic appliances
Instructions for the installer 9 2.3 Clearance above and around domestic appliances Extract from AS5601 REQUIREMENTS 1 Overhead clearances – (Measurement A) Range hoods and exhaust fans shall be installed in accordance with the manufacturer’s instructions. However, in no case shall the clearance bet...
Page 8 - 0 mm or more, or the horizontal surface shall be above the; Room ventilation
Instructions for the installer 10 2 Side clearances – (Measurements B & C) Where B, measured from the periphery of the nearest burner to any vertical combustible surface , is less than 200 mm, the surface shall be protected in accordance with Clause 5.12.1.2 to a height C of not less than 150 mm...
Page 9 - Discharge of combustion products
Instructions for the installer 11 2.5 Discharge of combustion products Discharge of combustion products must be guaranteed by means of hoods connected to a natural draught flue with certain efficiency, or by means of forced aspiration. An efficient aspiration system requires careful planning by a sp...
Page 10 - GAS CONNECTION; annealed copper pipe or
Instructions for the installer 12 3. GAS CONNECTION This appliance is suitable for installation with Natural Gas or ULPG (propane). Refer to page 12 for the relevant burner pressure and appropriate injector sizes. When the appliance is to be connected to Natural Gas then the pressure regulator suppl...
Page 11 - Electrical connection; Do not use reducers, adapters or shunts.; The manufacturer will not be liable; for any damage to persons or
Instructions for the installer 13 3.1 Electrical connection Make sure that the voltage and capacity of the power line conform to the data shown on the plate located under the casing. Do not remove this plate for any reason. The plug on the end of the supply cable and the wall socket must be the same...
Page 12 - ADAPTATION TO DIFFERENT TYPES OF GAS; Before performing any cleaning or maintenance work, detach the; Replacement of nozzles on the hob; unscrew the burner nozzles with a 7 mm socket wrench
Instructions for the installer 14 4. ADAPTATION TO DIFFERENT TYPES OF GAS Before performing any cleaning or maintenance work, detach the appliance from the electrical socket. The hob of the cooker is adjusted for use with either natural gas at a pressure of 1.0 kPa. If used with other types of gas, ...
Page 13 - Burner and nozzle characteristics table; Auxiliary
Instructions for the installer 15 4.2 Burner and nozzle characteristics table Burner ULPG – 2.75 kPa Nominal gas consumption (MJ/h) Injector (mm) Auxiliary (1) 3.9 0.54 Semi rapid (2) 6.3 0.68 WOK (4) 13.5 1.00 Burner NG – 1.0 kPa Nominal gas consumption (MJ/h) Injector (mm) Auxiliary (1) 3.9 0.90 S...
Page 14 - FINAL OPERATIONS; cooker has been tested, replace the plate inside the heating; Adjustment of minimum for natural gas
Instructions for the installer 16 5. FINAL OPERATIONS Having carried out the above adjustments, reassemble the appliance following, backwards, the instructions in paragraph “4.2 Burner and nozzle characteristics table”. After adjustment to a different kind of gas from the one for which the cooker ha...
Page 15 - Instructions for the user; USE OF THE COOKING HOB; Lighting the burners; in the flame caps correspond to the spark plugs and
Instructions for the user 6. USE OF THE COOKING HOB 6.1 Lighting the burners Before lighting the hob burners check that the flame caps are in the correct position and that their burner caps are in place, making sure thatthe holes A in the flame caps correspond to the spark plugs and thermocouples. P...
Page 16 - Practical advice for using the burners
Instructions for the user 18 6.2 Practical advice for using the burners For better use of the burners and lower gas consumption, use covered containers that are proportional in size to the burner to prevent the flame from licking the sides (see paragraph “6.3 Diameter of containers”). When water rea...
Page 17 - CLEANING AND MAINTENANCE; Cleaning stainless steel; Ordinary Daily Cleaning; Cleaning of cooking hob components
Instructions for the user 7. CLEANING AND MAINTENANCE Before any intervention, disconnect the power supply of the device. 7.1 Cleaning stainless steel To keep stainless steel in good condition it should be cleaned regularly after use. Let it cool first. 7.1.1 Ordinary Daily Cleaning To clean and pre...
Page 18 - Preventive maintenance; Gas connection: the gas connection must be checked periodically.; PROBLEMS AND CAUSES; PROBLEM
Instructions for the user 20 7.3 Preventive maintenance This appliance does not need any special maintenance. However, a few simple operations have to be carried out periodically to prevent malfunctioning: Burners: the burners must be cleaned periodically to ensure correct combustion; make sure that...