Page 2 - Notes on the Product; Product Names; Note; Note; Compatibility with the Previous Version; Note; Address label: Unique MAC address preset for the CP
Notes on the Product B3L − 2 CP 343-1 Lean for Industrial Ethernet / Manual Part B3L Release 03/2007 C79000-G8976-C198-04 Notes on the Product Product Names This description contains information on the following product S CP 343 − 1 Lean Order number 6GK7 343 − 1CX10 − 0XE0 as of hardware version 2 ...
Page 3 - Contents; Contents
Contents B3L − 3 CP 343-1 Lean for Industrial Ethernet / Manual Part B3L Release 03/2007C79000-G8976-C198-04 Contents Contents − Part A Ethernet CPs − General information see general part . . . . . . . . . . . . . . . . . . . Note Please remember that Part A of the device manual also belongs to the ...
Page 4 - Web Diagnostics
Contents B3L − 4 CP 343-1 Lean for Industrial Ethernet / Manual Part B3L Release 03/2007 C79000-G8976-C198-04 6.4.2 Initialization and Configuration B3L − 28 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.5 Example of Configuration and Programming B3L − 30 . . . . . . . . . . . ...
Page 5 - Properties / Services; Application
1 Properties / Services B3L − 5 CP 343-1 Lean for Industrial Ethernet / Manual Part B3L Release 03/2007C79000-G8976-C198-04 1 Properties / Services Application The CP 343 − 1 Lean communications processor is designed for operation in a SIMATIC S7-300 programmable logic controller. It allows attachme...
Page 7 - Configuration; Version STEP 7; Programming; Notice; current blocks in our Customer Support area on the Internet:
1 Properties / Services B3L − 7 CP 343-1 Lean for Industrial Ethernet / Manual Part B3L Release 03/2007C79000-G8976-C198-04 Configuration It is possible to download the configuration data to the CP over MPI orLAN/Industrial Ethernet. You require STEP 7 with NCM S7 for Industrial Ethernet(NCM IE) wit...
Page 8 - Requirements for Use; General Operation
2 Requirements for Use B3L − 8 CP 343-1 Lean for Industrial Ethernet / Manual Part B3L Release 03/2007 C79000-G8976-C198-04 2 Requirements for Use General Operation The CP can be operated in the following device families: S S7 − 300 stations with the CPU types − Standard − Compact − Modular S C7 con...
Page 11 - Installation and Commissioning
3 Installation and Commissioning B3L − 11 CP 343-1 Lean for Industrial Ethernet / Manual Part B3L Release 03/2007C79000-G8976-C198-04 3 Installation and Commissioning 3.1 Procedure / Steps Step Explanation / Meaning 1. Install the CP on the S7 standard rail.2. Establish the connection via the enclos...
Page 12 - Ground/Chassis Ground Concept; When shipped: Slider pushed in
3 Installation and Commissioning B3L − 12 CP 343-1 Lean for Industrial Ethernet / Manual Part B3L Release 03/2007 C79000-G8976-C198-04 Slider for setting the chassis ground contact Attachment to Industrial Ethernet: 2 x 8-pin RJ-45 jack Figure 3-1 Connectors of a CP 343 − 1 Lean with the Front Panel...
Page 13 - requirements of at least IP54 in compliance with EN 60529.; Warning
3 Installation and Commissioning B3L − 13 CP 343-1 Lean for Industrial Ethernet / Manual Part B3L Release 03/2007C79000-G8976-C198-04 Note The hinged front panel must be kept closed during operation.The module must be installed so that its upper and lower ventilation slits are not covered, allowing ...
Page 14 - Displays; SF; The LEDs have the following meaning:
4 Displays B3L − 14 CP 343-1 Lean for Industrial Ethernet / Manual Part B3L Release 03/2007 C79000-G8976-C198-04 4 Displays The display on the front panel consists of 8 LEDs that indicate the operating modeand the communication status. Front panel: SF BF RX/TX RUN STOP P1 P2 DC5V The LEDs have the f...
Page 15 - LEDs for displaying the mode; RUN
4 Displays B3L − 15 CP 343-1 Lean for Industrial Ethernet / Manual Part B3L Release 03/2007C79000-G8976-C198-04 LEDs for displaying the mode The different combinations of the LEDs on the front panel indicate the status: SF(red) BF (red) RUN (green) STOP (yellow) CP Operating Mode − S Starting up aft...
Page 16 - LEDs for displaying the CP communication status
4 Displays B3L − 16 CP 343-1 Lean for Industrial Ethernet / Manual Part B3L Release 03/2007 C79000-G8976-C198-04 LEDs for displaying the CP communication status In addition to the LEDs that signal the CP state, the following LEDs provideinformation about the status of the CP interface to Industrial ...
Page 17 - Performance Data; Number of Possible Connections over Ethernet; S7 connections; Characteristic Data for S7 Communication
5 Performance Data B3L − 17 CP 343-1 Lean for Industrial Ethernet / Manual Part B3L Release 03/2007C79000-G8976-C198-04 5 Performance Data 5.1 Number of Possible Connections over Ethernet Table 5-1 Characteristic Explanation / Values Permitted number of simultaneous connections in total over Industr...
Page 18 - Characteristics of the SEND/RECEIVE Interface; 00 CPU is the decisive factor.
5 Performance Data B3L − 18 CP 343-1 Lean for Industrial Ethernet / Manual Part B3L Release 03/2007 C79000-G8976-C198-04 5.3 Characteristics of the SEND/RECEIVE Interface Table 5-3 Characteristic Explanation / Values Number of ISO-on-TCP connections + TCP connections + UDP connections in total 8 max...
Page 19 - Characteristic Data for PROFINET IO; CP as PROFINET IO device
5 Performance Data B3L − 19 CP 343-1 Lean for Industrial Ethernet / Manual Part B3L Release 03/2007C79000-G8976-C198-04 5.4 Characteristic Data for PROFINET IO CP as PROFINET IO device The CP supports the following maximum configuration as a PROFINET IO device: Table 5-5 Characteristic Explanation /...
Page 20 - Configuring and Programming the CP as a PROFINET IO Device; Configuring and Programming the CP as a; “Intelligent” PROFINET IO Device; Lean can be configured so that the SIMATIC 300 station can be; Overview of the Preparatory Steps
6 Configuring and Programming the CP as a PROFINET IO Device B3L − 20 CP 343-1 Lean for Industrial Ethernet / Manual Part B3L Release 03/2007 C79000-G8976-C198-04 6 Configuring and Programming the CP as a PROFINET IO Device “Intelligent” PROFINET IO Device A CP 343 − 1 Lean can be configured so that...
Page 21 - Principle of Data Exchange over PROFINET IO; Data Exchange between controller and CP as PROFINET IO device; transferred as an; entire area
6 Configuring and Programming the CP as a PROFINET IO Device B3L − 21 CP 343-1 Lean for Industrial Ethernet / Manual Part B3L Release 03/2007C79000-G8976-C198-04 6.2 Principle of Data Exchange over PROFINET IO Data Exchange between controller and CP as PROFINET IO device Data exchange between a PROF...
Page 22 - PROFINET IO device mode in the properties dialog.; Installing the CP and Specifying it as PROFINET IO Device; Follow the steps below in STEP 7 / HW Config:
6 Configuring and Programming the CP as a PROFINET IO Device B3L − 22 CP 343-1 Lean for Industrial Ethernet / Manual Part B3L Release 03/2007 C79000-G8976-C198-04 6.3 Configuration Configuring the CP as a PROFINET IO device involves the two following activitiesin STEP 7: 1. The CP is inserted in a S...
Page 23 - This name may only be assigned once in the PROFINET IO line.; Download the configuration data to the SIMATIC 300 station.
6 Configuring and Programming the CP as a PROFINET IO Device B3L − 23 CP 343-1 Lean for Industrial Ethernet / Manual Part B3L Release 03/2007C79000-G8976-C198-04 2. Check and, if necessary, correct the IP address in the “Properties Ethernet” dialog. Notice The IP address of the PROFINET IO device an...
Page 24 - PROFINET IO Controller; Step 1: Configuring the PROFINET IO controller
6 Configuring and Programming the CP as a PROFINET IO Device B3L − 24 CP 343-1 Lean for Industrial Ethernet / Manual Part B3L Release 03/2007 C79000-G8976-C198-04 6.3.2 Assigning the PROFINET IO Device to a PROFINET IOController PROFINET IO Controller This section describes the configuration of PROF...
Page 25 - PROFINET IO controller.
6 Configuring and Programming the CP as a PROFINET IO Device B3L − 25 CP 343-1 Lean for Industrial Ethernet / Manual Part B3L Release 03/2007C79000-G8976-C198-04 Result: You will see the connector symbol for the PROFINET IO system beside the PROFINET IO controller. Step 2: Configuring the PROFINET I...
Page 26 - Step 3: Configuring the properties of the CP as PROFINET IO device; Continue configuration in HW Config as follows:; Deselect the “Assign IP address by IO controller” option.
6 Configuring and Programming the CP as a PROFINET IO Device B3L − 26 CP 343-1 Lean for Industrial Ethernet / Manual Part B3L Release 03/2007 C79000-G8976-C198-04 Step 3: Configuring the properties of the CP as PROFINET IO device Continue configuration in HW Config as follows: 1. Open the properties...
Page 27 - No further parameter assignment of the modules is necessary.; operated without exception at 100 Mbps full duplex.; Interface for Programming on the PROFINET IO Device; FCs
6 Configuring and Programming the CP as a PROFINET IO Device B3L − 27 CP 343-1 Lean for Industrial Ethernet / Manual Part B3L Release 03/2007C79000-G8976-C198-04 No further parameter assignment of the modules is necessary. Note By selecting suitable network components and setting the network propert...
Page 28 - Data consistency; Initialization and Configuration; Initialization; Length of the input data (when FC11 is called)
6 Configuring and Programming the CP as a PROFINET IO Device B3L − 28 CP 343-1 Lean for Industrial Ethernet / Manual Part B3L Release 03/2007 C79000-G8976-C198-04 Data consistency The length information in the block call must be identical to the total length of theinput or output data configured for...
Page 29 - Reasons for reinitialization; configuration change.; Watchdog
6 Configuring and Programming the CP as a PROFINET IO Device B3L − 29 CP 343-1 Lean for Industrial Ethernet / Manual Part B3L Release 03/2007C79000-G8976-C198-04 Reasons for reinitialization The PROFINET IO device requests reinitialization by the user program in thefollowing situations: S The length...
Page 30 - Example of Configuration and Programming
6 Configuring and Programming the CP as a PROFINET IO Device B3L − 30 CP 343-1 Lean for Industrial Ethernet / Manual Part B3L Release 03/2007 C79000-G8976-C198-04 6.5 Example of Configuration and Programming The configured input/output modules must be accessed in the user program of thePROFINET IO d...
Page 31 - Transfer the process inputs (DB10) to the I addresses with PNIO_SEND; The call interface PNIO_SEND in the user program
6 Configuring and Programming the CP as a PROFINET IO Device B3L − 31 CP 343-1 Lean for Industrial Ethernet / Manual Part B3L Release 03/2007C79000-G8976-C198-04 Transfer the process inputs (DB10) to the I addresses with PNIO_SEND For the configured I addresses, you will need to make data areas avai...
Page 32 - The call interface PNIO_RECV in the user program
6 Configuring and Programming the CP as a PROFINET IO Device B3L − 32 CP 343-1 Lean for Industrial Ethernet / Manual Part B3L Release 03/2007 C79000-G8976-C198-04 Transfer the O addresses to the process outputs (DB11) with PNIO_RECV For the configured O addresses, you will need to make data areas av...
Page 33 - Requirements and Use; Settings for Access to Diagnostic Data; Starting and Working with Web Diagnostics
7 Web Diagnostics B3L − 33 CP 343-1 Lean for Industrial Ethernet / Manual Part B3L Release 03/2007C79000-G8976-C198-04 7 Web Diagnostics With Web diagnostics, the CP provides you with the option of calling up the mostimportant settings of a connected station and the status of their networkconnection...
Page 34 - Diagnostics Pages of the CP; Layout of the Diagnostics Pages
7 Web Diagnostics B3L − 34 CP 343-1 Lean for Industrial Ethernet / Manual Part B3L Release 03/2007 C79000-G8976-C198-04 3. Select the display language you require from the “Language” drop-down list box at the top right. The following languages are available: S English S Deutsch S Français S Español ...
Page 35 - Start Page; Parameter
7 Web Diagnostics B3L − 35 CP 343-1 Lean for Industrial Ethernet / Manual Part B3L Release 03/2007C79000-G8976-C198-04 7.2.1 Start Page This page displays general device data and the status of the connected CP. Parameter Function General Station name Configured name of the station in which the CP is...
Page 37 - Rack Configuration
7 Web Diagnostics B3L − 37 CP 343-1 Lean for Industrial Ethernet / Manual Part B3L Release 03/2007C79000-G8976-C198-04 7.2.3 Rack Configuration The slots of the station and general data along with the status of the devices isdisplayed here. Parameter Function Rack Configuration (rack name) Slot Slot...
Page 39 - Diagnostic Buffer
7 Web Diagnostics B3L − 39 CP 343-1 Lean for Industrial Ethernet / Manual Part B3L Release 03/2007C79000-G8976-C198-04 7.2.4 Diagnostic Buffer This table lists all the events in the chronological order in which they werereceived. The latest entry is at the start and the oldest entry at the end of th...
Page 40 - Industrial Ethernet; “Parameters” Tab
7 Web Diagnostics B3L − 40 CP 343-1 Lean for Industrial Ethernet / Manual Part B3L Release 03/2007 C79000-G8976-C198-04 7.2.5 Industrial Ethernet “Parameters” Tab This page shows you the various parameters of the MAC address, the IP addressand the LAN attachments. Parameter Function Network attachme...
Page 41 - “Statistics” Tab; “TCP Connections” Tab; This page informs you about existing TCP connections.; “UDP Connections” Tab; This page informs you about existing UDP connections.
7 Web Diagnostics B3L − 41 CP 343-1 Lean for Industrial Ethernet / Manual Part B3L Release 03/2007C79000-G8976-C198-04 “Statistics” Tab This page displays information on sent and received frames since the last modulerestart. Parameter Function Data packets sent Number of error-free frames sent, numb...
Page 42 - PROFINET IO; Parameters of a PROFINET IO Device
7 Web Diagnostics B3L − 42 CP 343-1 Lean for Industrial Ethernet / Manual Part B3L Release 03/2007 C79000-G8976-C198-04 7.2.6 PROFINET IO This page provides you with information on the most important parameters of thePROFINET IO configuration. Parameters of a PROFINET IO Device Parameter Function PR...
Page 44 - Compatibility with Predecessor Products; Extended Functionality; New: Enhanced functions compared with module 6GK7 343; Replacing Older Modules / Replacing Faulty Modules; Use as a Replacement:
8 Compatibility with Predecessor Products B3L − 44 CP 343-1 Lean for Industrial Ethernet / Manual Part B3L Release 03/2007 C79000-G8976-C198-04 8 Compatibility with Predecessor Products 8.1 Extended Functionality New: Enhanced functions compared with module 6GK7 343 − 1CX10 − 0XE0 with firmware vers...
Page 45 - Module Replacement
8 Compatibility with Predecessor Products B3L − 45 CP 343-1 Lean for Industrial Ethernet / Manual Part B3L Release 03/2007C79000-G8976-C198-04 Module Replacement When replacing an older module with the module described here, keep to the stepsoutlined below: Table 8-1 Originally configured module Con...
Page 46 - Further Notes on Operation; Memory Reset; Available Functions; The CP has a two-level function available for resetting memory:; How to Use the Function; You can start the memory reset functions in STEP 7.
9 Further Notes on Operation B3L − 46 CP 343-1 Lean for Industrial Ethernet / Manual Part B3L Release 03/2007 C79000-G8976-C198-04 9 Further Notes on Operation 9.1 Memory Reset Available Functions The CP has a two-level function available for resetting memory: S Clear / resetFollowing this memory re...
Page 47 - Behavior after Memory Reset; The configuration data must then be reloaded.; Working with Fast Ethernet; How Automatic Switchover of the Network Settings Works; 00 Mbps full duplex.; Autocrossing
9 Further Notes on Operation B3L − 47 CP 343-1 Lean for Industrial Ethernet / Manual Part B3L Release 03/2007C79000-G8976-C198-04 Behavior after Memory Reset The CPU in the S7 station does not recognize that the CP memory was reset. TheCP therefore changes to the “stopped with error” state (see Chap...
Page 48 - Automatic Setting or Individual Network Settings
9 Further Notes on Operation B3L − 48 CP 343-1 Lean for Industrial Ethernet / Manual Part B3L Release 03/2007 C79000-G8976-C198-04 Automatic Setting or Individual Network Settings As default, the CP is configured for automatic detection (autosensing). As soon asyou define a configuration manually wh...
Page 49 - SNMP Agent; SNMP
9 Further Notes on Operation B3L − 49 CP 343-1 Lean for Industrial Ethernet / Manual Part B3L Release 03/2007C79000-G8976-C198-04 S Recommendation: Change “individual network settings” only over MPI.If you modify the LAN settings in the properties dialog of the CP in the “Port Parameters” tab, these...
Page 50 - Access Permissions using Community Name; Influence of MPI on Connections via Industrial Ethernet; MPI
9 Further Notes on Operation B3L − 50 CP 343-1 Lean for Industrial Ethernet / Manual Part B3L Release 03/2007 C79000-G8976-C198-04 Access Permissions using Community Name The CP uses the following community names for assigning permissions: S For read access: “public” S for read and write access: “pr...
Page 51 - 40 bytes is being processed are aborted temporarily.; Special Features of IP Configuration; over DHCP; Reserved Port Numbers
9 Further Notes on Operation B3L − 51 CP 343-1 Lean for Industrial Ethernet / Manual Part B3L Release 03/2007C79000-G8976-C198-04 S The connections on which a job on the communication bus with a data length > 240 bytes is being processed are aborted temporarily. S FETCH/WRITE connections are temp...
Page 52 - Obtaining the IP Address over DHCP; When the lease expires the reaction of the CP is as follows:; Other information available about the CP; FAQ
9 Further Notes on Operation B3L − 52 CP 343-1 Lean for Industrial Ethernet / Manual Part B3L Release 03/2007 C79000-G8976-C198-04 9.8 Restart after Detection of a Duplicate IP Address in theNetwork To save you time-consuming troubleshooting in the network, the CP detects doubleaddressing in the net...
Page 53 - 0 How to Load New Firmware; Requirements; Requirements for Downloading; How to Download New Firmware; What to do if a Download is Interrupted
10 How to Load New Firmware B3L − 53 CP 343-1 Lean for Industrial Ethernet / Manual Part B3L Release 03/2007C79000-G8976-C198-04 10 How to Load New Firmware Requirements You download new firmware to a SIMATIC NET CP using the firmware loadershipped with STEP 7 / NCM S7. Requirements for Downloading ...
Page 54 - 1 Technical Specifications
11 Technical Specifications B3L − 54 CP 343-1 Lean for Industrial Ethernet / Manual Part B3L Release 03/2007 C79000-G8976-C198-04 11 Technical Specifications Transmission rate 10 Mbps and 100 Mbps InterfacesConnection to Ethernet 2 x RJ − 45 jack Power supply DC +24 V (permitted range: +20.4 V throu...