Page 2 - Introduction; Table of Contents; Drainage: Do Not drain into swimming pool or onto grounds.
Introduction This manual includes information for theinstallation, operation and maintenance of theSCN60 residential ice machine. The SCN60 was developed to offer fans ofScotsman’s Nugget Ice form the ability to have thatice in their homes. Previously Nugget Ice was onlyavailable in commercial estab...
Page 3 - Minimum water pressure: 20 psi; Water Quality; RO Water; Electrical power
Product Description: This ice machine is designed to be used indoors, in a controlled environment or outdoors within certainlimits. The SCN60 is made up of two major systems: theice making system and the ice storage system. The ice making system is a continuous flow type icemachine, it makes ice whe...
Page 4 - Cabinet Dimensions
Cabinet Dimensions May 2011 Page 3 SCN60User's Manual 14 7/8" AIR IN AIR OUT 3/4" SHEET METAL DOOR FRONT - IF DOOR KIT INSTALLED.63 MIN. CABINET DOOR 22" 29 1/4" 1" LEG ADJUSTMENT(4) PLACES 2 3/4" 2 3/8" DOOR KIT AND HANDLE 3/4" 4" 33 3/8" MIN. 34 3/8" MAX...
Page 5 - Location Recommendations:; KKPF; Built In Situations
Location Recommendations: The machine can be built into a cabinet. It is an aircooled refrigeration system and so air flows in andout of it through the grill at the bottom front. Thegrill must not be blocked by any covering door orother obstruction. There are two models, one is a gravity drain typea...
Page 7 - Door Panel Attachment
Door Panel Attachment May 2011 Page 6 SCN60User's Manual Gasket ScotsmanDoor Panel Cover Machine Screw Use Upper Hole at the Top Use Lower Hole at the Bottom Hole Plug
Page 8 - Door Swing; Installation Notes
Door Swing Note: Prior models had separate hinge bracketsand different directions to change swing. Moving the hinges allows the door to open fromeither the left or right side. Change swing beforeattaching door panel. To change: 1. Remove innermost screw holding each hingeto cabinet, loosen the other...
Page 9 - Plumbing - Pump Model; Drains; Connect Water Supply
Plumbing - Pump Model Drains There are two types of ice machine models, onethat drains by gravity and one that has an internaldrain pump. Drain Pump Model drain installation 1. Locate the coil of 3/8” ID plastic drain tubingsecured to the back of the unit. 2. Route the plastic drain tube from the ba...
Page 10 - Plumbing: Gravity Drain Model; Water Supply
Plumbing: Gravity Drain Model Caution: Restrictions in the drain system to themachine will cause water to back up into the icestorage bin and melt the ice. Gravity drain tubingmust be vented, have no kinks and slope to thebuilding drain. Air gaps are typically required bylocal code. 1. Place the ice...
Page 11 - Electrical and Start Up; Installation check list:
Electrical and Start Up The ice machine is supplied with a power cord. Donot remove the grounding pin from the cord’s plug.Do not use extension cords. Follow all codes. Connect the machine to its own properly grounded115 volt, 15 amp circuit. 1. If the electrical outlet for the ice maker is behindth...
Page 12 - Use; Control Panel
Use No special instructions are needed for use. Justtake as much ice as you need, the machine willreplace it. A scoop is provided, and it can be storedin the machine using the loop of tubing on the rightside as a holder. The machine can be shut off anytime by justpushing and releasing the On/Off but...
Page 13 - Maintenance; strongly recommends regular
Maintenance Scotsman strongly recommends regular maintenance of this ice machine. During normal operation mineral scale that is in the water supplywill gradually build up on the ice making surfaces.That build up can cause excessive loading of theice making system, which can cause prematurefailure. R...
Page 14 - Push Tab
How to remove scale from the ice making system. Cleaning this machine involves adding a solution of scale remover and water to the ice machine andcontinuing to add it as it makes ice. The scaleremover must be diluted to the correct ratio. Asquirt bottle will make adding the scale removermuch easier ...
Page 16 - Check the top bearing.
11. Press and HOLD the both the Clean-Reset andOn/Off buttons for 5 seconds. The Time to Cleanlight will blink on and off. 12. The auger motor alone will be operating for 10minutes, after that the compressor will start and inabout 5-8 minutes the machine will start to makeice. The Time to Clean ligh...
Page 17 - July; What to do before calling for service
What to do before calling for service Low capacity • Check for restricted drain or standing waterin the bin • Clean the air cooled condenser fins • Clean the ice making system No ice • Check on-off switch • Check electrical breaker • If the Check Water light is flashing Red,check water supply. The c...
Page 18 - SCOTSMAN ICE SYSTEMS; 01Corporate Woods Parkway
17-3341-01 Rev. B SCOTSMAN ICE SYSTEMS 101Corporate Woods Parkway Vernon Hills, IL 60061 800-726-8762 www.scotsman-ice.com